ProblemPossible causeRemedy The fuse is blown.Make sure that the fuse is the cause of the malfunction. If the fuse is blown again and again, contact a quali- fied electrician. Burner cap and crown are placed incorrectly.Place the burner cap and crown correctly.The flame extinguishes im- mediately after ignition.Thermocouple is not heated up sufficiently.After lightning the flame, keep the knob pushed for equal or less than 10 sec- onds.The flame ring is uneven.Burner crown is blocked with food...
Page 12
7.3 Labels supplied with the accessories bag Stick the adhesive labels as indicated below:A. Stick it on Guarantee Card and send this part (if applicable). B. Stick it on Guarantee Card and keep this part (if applicable).C. Stick it on instruction booklet.8. INSTALLATIONWARNING! Refer to Safety chapters.8.1 Before the installation Before you install the hob, write down the information bellow from the rating plate. The rating plate is on the bottom of the hob. Model...
Page 13
However, if the room has a door whichopens directly to the outside no air vent is required even if the volume is between 5 m³ and 11 m³. If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I.S. 813 Current Editions Table Four.Location The hob may be located in a kitchen, a kitchen/diner or...
Page 14
8.4 Injectors replacement 1. Remove the pan supports. 2. Remove the caps and crowns of the burner. 3. With a socket spanner 7 remove the injectors and replace them with the ones which are necessary for the type of gas you use (see table in "Technical Information" chapter). 4. Assemble the parts, follow the same procedure backwards. 5. Replace the rating plate (it is near the gas supply pipe) with the one for the new type of gas supply. You can find this plate in the package supplied with the...
Page 15
2.The supply system is equipped with an efficient earth connection in compliance with the current standards and regulations 3. The outlet or omnipolar switch used for connection is easily accessible with the appliance installed. The appliance is supplied with a 3 core flexible power cable with a 3 amp plug. If it is necessary to change the fuse, use a 3 amp ASTA-approved (BS 1362) fuse. A. Green and Yellow B. 3 amp fuse C. Brown D. Cord clamp E. Blue The wires in the cord are coloured as follows: Green...
Page 16
8.8 Assembly 1. 2. 3. 4. If a furniture unit is installed at a distance of 400 mm above the hob, there must be a minimum safety distance of 50 mm to the left or right from the edge of the hob. 5. 6. 7. 8. www.aeg.com16 min. 55 mm min. 650 mm 560 mm min. 100 mm 30 mm4 80 mm min. 600 mm 50 mm400 mm
Page 17
9. 10. 11. CAUTION! Install the appliance only on a worktop with flat surface.8.9 Possibilities for insertion The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary.Kitchen unit with door or drawer A. Removable panel B. Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit. 9. TECHNICAL...
Page 18
9.2 Bypass diametersBURNERØ BYPASS 1/100 mmRapid52Semi-rapid42Auxiliary329.3 Other technical data TOTAL POWER: Gas original:G20 (2H) 20 mbar = 7,5 kWGas replacement:G30 (3+) 28-30 mbar = 542 g/h G31 (3+) 37 mbar = 532 g/hElectric supply:220-240 V ~ 50/60 Hz 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuseAppliance category:II2H3+ Gas connection:R 1/2" Appliance class:3 9.4 Gas burners for NATURAL GAS G20 20 mbarBURNERNORMAL POWER kWMINIMUM POWER kWINJECTOR MARK 1/100...
Page 19
10. ENERGY EFFICIENCY10.1 Product information according to EU 66/2014Model identification HG654350SM, HG65SM4350Type of hob Built-in hobNumber of gas burners 4 Energy efficiency per gas burner (EE gas burner) Left rear - Semi-rapid57.0%Right rear - Semi-rapid58.2%Left front - Rapid54.1%Right front - Auxiliarynot applicableEnergy efficiency for the gas hob (EE gas hob) 56.4% EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of energy - General 10.2 Energy saving • Before use,...