Page 11
ADVANCE LIFTS PIT DIAGRAM (K’s, T’s, 2000, 3000, & 4000 SERIES) *When mounting a “T-Series” lift on a pad it is necessary to supply a cutout in the concrete to allow passage of the hose under the base frame. T-Series lifts have no clearance between the platform and ground, any hose run through or over the base frame will be damaged when the platform is lowered. Installation Bill of Material* 1. One (1) Advance Lift...
Page 12
SECTION 5: OPERATING INSTRUCTIONS Hydraulic scissors lifts have an excellent safety record overall, but as with all moving equipment they can be dangerous. Operators must use common sense and take responsibility for the safety of everyone near the lift. They must use the devices provided and be careful not to surprise anyone in the area with the movement of the lift. The most common accidents that occur are people walking off the end of the lift and people tripping over the hinged bridge...
Page 13
COMPATIBLE LOADING EQUIPMENT GUIDE: Each Advance lift is designed with a weight capacity and platform design for specific types of loading equipment. Using the wrong type of loading equipment on a given series of lifts will invite unintentional overloading. For safe operation, follow these guidelines and be careful to never exceed the nameplate. Calculate the weight of the heaviest types of loads you expect to handle...
Page 14
Daily Operation (Continued) 5. If the unit has a traveling electrical cord, the operator must insure that it is kept away from the lift as it rises and lowers. 6. When raising or lowering the lift, the load should be centered on the platform (that is, the load should be evenly distributed and its center of gravity should be at the center of the platform). 7. If a unit is equipped with both a hinged bridge and a hinged ramp, be sure that the operators know the difference and never...
Page 15
P 5-4 Placing Bridge in Truck With bridge folded back toward platform raise the dock lift until the top the bridge is just above the opening of the truck, push the bridge against the truck with your foot while controlling the fall with the safety chains. As the dock lift is raised, the bridge will cam over onto the truck bed and lay flat for loading and unloading. Removing Bridge from Truck and Securing Begin to lower the dock lift until the bridge starts to cam up over the end of the...
Page 16
SECTION 6: MAINTENANCE INSTRUCTIONS The routine maintenance of this equipment is minor and consists of periodic checks. Weekly: Once a week, or after repetitive operation, the lift should be raised to its full height. This will get rid of cylinder oil seepage build-up and lubricate the upper cylinder barrel. Monthly: Check that the hydraulic fluid level in the reservoir is 1” to 2” from the top of the tank, depending on model, with the unit fully lowered. It is strongly urged that a...
Page 17
SECTION 6: (CONTINUED) Maintenance Cautions: 1. Always remember that this is a piece of machinery with large moving parts that can seriously hurt you. 2. Read this manual in its entirety before attempting service work. 3. Always use the maintenance device if you are going to work on the unit in the elevated position or reach under the platform. (See the illustrations at the end of this section for proper positioning and engagement of the maintenance supports.) 4. It may be...
Page 18
Section 6: (Continued) Recommended Lift Blocking Procedures WARNING! Only authorized personnel should perform inspection or maintenance and service procedures. Unauthorized personnel attempting these procedures do so at the risk of severe injury or death. DANGER! Failure to properly adhere to lift blocking procedures is to risk the sudden and uncontrolled descent of the lift during maintenance or inspection. A falling lift can cause severe injury or death. This procedure describes...
Page 19
Recommended Lift Blocking Procedures (continued) DANGER! If for any reason you are unable to lower the lift completely onto the maintenance device(s), stop immediately and consult the factory. Failure to properly use the factory approved maintenance device(s) could result in severe injury or death. 5. Once the maintenance device(s) is/are properly and securely engaged, continue to press the down button, valve or switch for an additional 5-10 seconds to relieve all pressure in the...
Page 20
Fig. 1 Fig. 2 CAUTION! Read the entire lift blocking procedure and all warnings before attempting to use the maintenance bar. ALL MODELS Never use the maintenance device when the platform has a load. Remove the load first, then brace for service or maintenance. Check that the maintenance bar is well seated and remains so during heavy wrenching or maintenance operations. FOR SERIES 2000K Place the...