    SECTION 11.  TROUBLESHOOTING (Continued) 
     
    6.  Equipment in which the cylinders are field installed may have incorrect alignment of 
    cylinders, causing binding. Measure and ascertain that the cylinders are in the 
    correct alignment with the equipment and with each other. Binding cylinders will 
    often cause a “shuddering” vibration when the equipment is operating. 
    7.  Oil may be too thin for ambient temperatures. See A-12 
     
    C.  Motor labors or heats excessively:  
    1.  Voltage may be too low. See A-3. 
    2.  Wiring may be incorrect. Check that one leg of the motor lines is not open or 
    grounded. 
    3.  Pump may be overheating from oil starvation that develops high internal heat, 
    heating   both the motor and the   pump, eventually causing pump failure. See A-1 
    through A-9. 
    4.  Oil may be too thick for ambient temperature. See “ Fluid Recommendations”. 
    Binding cylinders. See B-6. 
    5.  Pump may be overheating due to insufficient lubrication caused by oil being too thin. 
    See A-12. 
     
    D. Operation is “spongy”: 
     
    1.  Bleed the cylinders to release trapped air by lowering the equipment to the fully 
    down position and hold the down button depressed for an additional 20 seconds.  
    Raise lift and repeat this procedure several times.  Check that the oil completely fills 
    the clear suction hose at all times.  If the level falls back to the reservoir oil level, 
    check suction lines and fittings for an air leak. 
    2.  Check for oil starvation.  See A, 1-9. 
    3.  Do not confuse “spongy” operation with small surges caused by foreign material on 
    equipment wheel roller plates. 
     
     E.  Equipment lowers too slowly: 
    1.  Pressure filter in pipe outlet of power unit may require cleaning.  See “ Component 
    Information” for proper procedure. 
    2.  Check for pinched hose, tubing, or obstruction in piping lines. 
    3.  Check “Fluid Recommendations” for your ambient temperature type. Oil may be too 
    thick.  See also H-6. 
    4.  Foreign material in flow control valve.  With equipment fully lowered, remove and 
    flush out any foreign material.  Do not change flow control setting, as equipment 
    could be damaged by high speeds.  See “ Component Information” for proper way to 
    remove, clean, and install the flow control valve. 
    5.  Equipment having two down solenoid valves and/or flow control valves may have 
    one valve inoperative. 
    6.  Binding cylinders.  See B-6. 
     
     
     
     
     
     
    P 11-3 
     
      
    						
    							 
     
    SECTION 11.  TROUBLESHOOTING (Continued) 
     
    F. Equipment lowers too fast: 
     
    CAUTION! This can develop into a dangerous condition, the equipment reaching 
    destructive speed.  Find and correct this condition before allowing use of this 
    equipment. 
     
    1.  Check for leaking hoses, particularly cracked fittings or other damage caused by 
    equipment motion near the equipment and power unit, over-tightening of fittings until 
    they develop hairline cracks.  Check underground conduits for evidence of fluid 
    leaks. 
    2.  Inspect the check valve.  The combination of the flow rates of the down flow control 
    valve and a check valve stuck open due to foreign material, could increase the 
    lowering speed.  See G-2. 
    3.  If the equipment lowers initially at a normal rate, then speeds up as the equipment 
    lowers, check the flow control valve(s).  Foreign material could stick, not allowing the 
    pressure compensated function of the control to operate normally. See “Component 
    Information” for the method of removal and replacement. 
    4.  Oil may be too thin.  See A-12. 
     
    G.   Lift raises then lowers back down: 
     
    1.  Down valve may be incorrectly wired or stuck open due to dirt in the system.  See  
    A-10, a. & b.  
    2.  Check valve may be stuck open due to dirt in the system.  See “Component 
    Information” for removal, cleaning and installation.  If pump and motor turns 
    backward while the lift is lowering back down, the check valve is certainly 
    inoperative. 
    3.  Cylinder packing may be leaking.  Check for oil leakage, see “ General Hydraulic 
    Information” and section on “Cylinder Repair Procedures”. 
    4.  Check for leaking hoses, fittings, or evidence of oil in underground conduit runs. 
     
    H. Equipment has raised but will not lower, or lowers partly: 
     
    1.  Check both main and transformer secondary fuses. 
    2.  Incorrect down solenoid wiring. 
    3.  Stuck down solenoid valve.  See A-10b, however do not remove the down solenoid 
    body, as the equipment will come down with nothing to hold it in place. 
    4.  Faulty down solenoid coil. Coil can be removed safely for replacement.  As in step 3, 
    do not remove valve body. 
    5.  Down limit switch (if used) or electric toe guards (if used) inoperative or incorrectly 
    wired.  If you have electric toe guards, check that the hydraulic hose is secured to 
    the bottom of the pit so it cannot accidentally trip the electric toe guard. 
    6.  Maintenance bar or leg or other object blocking down travel. Do not pry out any 
    object blocking down travel, because the hydraulic pressure has already been 
    removed when the down button was pressed, and the equipment will fall at a 
    dangerous speed.  Raise the equipment slightly using the up button, remove object, 
    then press the down button. 
     
     
     
    P 11-4 
      
    						
    							 
     
    SECTION 11.  TROUBLESHOOTING (Continued) 
     
    7.  Improper oil for ambient temperatures.  Oil may be too thick, causing improper 
    operation of velocity fuses (if used).  See “Component Information’ on velocity fuses. 
    Warm the cylinders by wrapping heat tape (of the type used for water pipes) around 
    the cylinder. Later, after operation is normal, change to proper oil as per “Fluid 
    Recommendations”. 
    8.  Binding Cylinders. See B-6 
     
    I.  Equipment raises slightly, then equipment stops and motor stalls: 
     
    Check the suction line filter. Filter may be clogged, allowing slight movement until 
    grime seals off filter.  Check the suction filter for buildup of “varnish”.  If necessary, 
    remove the suction filter, hold the suction hose down into the oil, and try normal up 
    operation of equipment.  If operation returns to normal either clean or replace the 
    suction line filter.  See the “Component Information” section for procedure and 
    proper placement of the suction hose. 
     
    J.  Oil leaking or spraying out of the reservoir: 
     
    1.  Reservoir may be over filled with hydraulic fluid. Drain fluid from tank until the fluid 
    level is 1” from the top of the reservoir.  
    2.  Clogged air breather allowing reservoir to build up positive pressure, then spraying 
    oil.  Try unit operation with air breather removed and clean or replace the air 
    breather if this corrects the condition. 
     
    K.  Equipment will not raise, motor will not run: 
     
    1.  Control fuse has blown. 
    2.  Motor starter overload has tripped.  Depress reset button on controller. 
    3.  Line fuse blown, single phasing motor or motor starter overload tripping.  See #2 
    above. 
    4.  Initial installation: Line voltage 230V and transformer wired for 460V.  This will give 
    12V-control voltage instead of 24V, and motor starter will not operate.  Check to 
    make sure motor was not wired for 460V before trying operation.  The same 
    situation applies to 115V control voltage.  Use a good AC voltmeter to check for 
    proper control voltage. 
    5.  Check transformer for loose screw terminals at the various connection points 
    including jumpers and under the fuse clips. 
    6.  Check push button station for proper operation and its wiring to the controller. 
     
    L.  Down solenoid or Magnetic Starter Coil burns out routinely: 
     
    1.  Transformer may be wired wrong.  As an example, a 460V line with the transformer 
    and primary wired for 230V will give the control voltage of 48V instead of 24V.  
    (Same doubling voltage applies to 115V control transformers.)  This will burnout 
    coils ranging from immediately to several month intervals, depending on the stamina 
    of the coil.  Correct the condition. P 10-5 
    2.  The transformer may be defective.  Check control voltage with a good AC voltmeter. 
     
     
     
    P 11-5  
    						
    							 
     
     
    SECTION 11.  TROUBLESHOOTING (Continued) 
     
    3.  Although very rare, high voltage spikes may be coming in on the power lines at 
    random, burning out coils.  This cannot be detected with a power company recorder, 
    A “Varistor” can be purchased and easily installed on control systems to protect the 
    coils.  More severe cases on both 115V or 24V control systems may need a special “ 
    High Insulation Transformer” in place of the standard control transformer. 
     
    M.  Equipment does not lift rated load, or raises load about 1” then stops: 
    1.  Check troubleshooting section (A), 2 through 11.  Check if platform roller wheels roll 
    freely with no binding as lift raises and lowers. 
    2.  Lift may be overloaded.  If a lift is listed as capable of fork truck loading, bear in mind 
    that most “sit-down” rider fork trucks weigh at least 5,000 to 7,500 pound empty. 
    3.  Platform may be shifted or damaged from transit or unintentional abuse. 
    A.  Check if the inside edge of the bevel toe guard is rubbing against the base frame 
    in the fully lowered position.  Look for scratch marks on the base frame.  Bend 
    back bevel toe guards as required and see “b” below. 
    B.  Check if the platform roller wheels are running straight on their platform members 
    as the lift raises and lowers and legs or wheels are not rubbing on nearby 
    platform members.  Consult Advance Lifts on how to straighten out a platform. 
    C. Check that the platform roller wheels are actually rolling as unit rises.
     
    4. There may actually be no problem.  Many shipping tickets contain estimated weights 
    much lower than the actual weight.  The lift may be seeing a load based on shipping 
    tickets, well above lift capacity.  In this case the lift would not generally raise the 1” 
    and stop, generally it will not lift at all from the full lowered position. 
     
    N.  Breather lines do not stay connected. 
    1.  Be certain that the lines are not pinched. 
    2.  Check that there is no debris in the lines. 
    3.  Once a line has been removed from the fitting, the hose must be cut back before 
    reinstallation. 
    4.  If lines are completely filled with oil, drain oil out and test cylinders for seal failures. 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    P 11-6 
      
    						
    							 
     
     
    SECTION 12. ADVANCE LIFTS INC. PARTS AND LABOR WARRANTY 
     
     
    For a period of two years from date of shipment from the Company’s plant, the 
    Company agrees to replace or repair, free of charge, any defective parts, material or 
    workmanship on new equipment. This shall include electrical and hydraulic 
    components. 
     
    For a period of ten years from date of shipment from Company’s plant, the Company 
    agrees to replace or repair any defective structure. 
     
    Company authorization must be obtained prior to the commencement of any work. The 
    Company reserves the right of choice between effecting repairs in the field or paying all 
    freight charges and effecting the repairs at the Company’s plant. The Company further 
    reserves the right of final determination in all warranty considerations. Evidence of 
    overloading, abuse, or field modification of units without Company approval shall void 
    this warranty. No contingent liabilities or freight damage will be accepted.
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    P 12-1 
     
      
    						
    							 
     
    ADVANCE LIFTS INC PART LISTS 
    1045/1055 PARTS LIST 
     
     
    TO ORDER PARTS CALL 800-843-3625  
    OR E-MAIL [email protected] 
     
    000-312000-312 GENERAL DESCRIPTION PART #GENERAL DESCRIPTIONPART #
    MECHANICAL:
     COMPLETE CONTROL BOX: 
    WHEEL
     P-A-0074115V,PRI,1PH,24V,SEC, NO OPTIONS P-004-399
    WHEEL PIN (3/4 x 3-3/4)
     P-A-0075230V,PRI,1PH,24V,SEC, NO OPTIONS P-004-800
    WHEEL PIN SNAP RING
     P-001-877230V,PRI,3PH,24V,SEC, NO OPTIONS P-004-802
    MAIN AXLE PIN (1-3/4 x 10-13/16)
     P-A-0073480V,PRI,3PH,24V,SEC, NO OPTIONS P-004-806
    MAIN AXLE PIN SNAP RING
     P-001-063
    HANDRAIL
     P-004-440TRANSFORMER: (SELECT BY VOLTAGE AND OPTIONS)
    SNAP RING FOR HANDRAIL
     P-001-876100VA transformers with a warning light or bell. 
    SAFETY CABLE 67 SPAN P-004-387115-230V,24V, 1 PHASEP-001-845
    HINGED STEEL BRIDGE  (18 x 60)
     P-025-037240-480V,24V, 3 PHASEP-001-844
    HINGED RAMP (30 x 60)
     P-D-2764S6115-230V,24V, 1 PHASE, WITH A BELL OR LIGHT P-000-746
    BASE MOUNTED FLIPPER WHEEL ASSEMBLY
     P-D-2764S5240-480V,24V, 3 PHASE, WITH A BELL OR LIGHT P-000-399
    DOLLY HANDLE ASSEMBLY
     P-D-1465S11
    COVER PANEL FOR POWER UNIT
     P-005-778CONTACTOR, MOTOR STARTER:  
    115V,1PH CONTACTORP-000-692
    CYLINDER:
     230V,1PH CONTACTORP-000-692
    CYLINDER, 1045/1055
     P-D-12752230V,3PH CONTACTORP-000-690
    CYLINDER PACKING KIT FOR 1045/1055
     P-026-183480V,3PH CONTACTORP-000-690
    CYLINDER ROD (1-3/4 x 53-1/16)
     P-A-10403
    CYLINDER BEARING ASSEMBLY 
     P-A-10405OVERLOAD: (SELECT BY VOLTAGE AND PHASE)
    LOWER CYLINDER PIN (1 x 4-1/8)
     P-A-8606115V/1PH OVERLOADP-000-700
    UPPER CYLINDER PIN (1 x 3-5/8)
     P-A-0548230V/1PH OVERLOADP-000-698
    CYLINDER PIN SNAP RING
     P-001-876230V/3PH OVERLOADP-000-696
    FLOW CONTROL CARTRIDGE (6 GPM) PRE 4/00
     P-001-305460V/3PH OVERLOADP-000-694
    GOLD HEXAGONAL FLOW CONTROL AFTER 4/00
     P-015-397
    HYDRAULIC HOSE (1/4x19.25 ) After 4/1/00 Only
     P-015-551MOTOR: (SELECT BY VOLTAGE AND PHASE) 
    HYDRAULIC HOSE (1/4x 27”) After 4/1/00 Only P-015-437115/208/230 VOLT, 1 PH, LEESON, 1202274-00 P-000-319
      208/230/460/480 VOLT, 3 PH, LEESON 120276-00  P-000-318
    HYDRAULIC: (COMMON TO ALL POWER UNITS)
     OPTIONS:
    HYDRAULIC PUMP
     P-000-356BELL AND LIGHT COMBOP-023-651
    MANIFOLD VALVE ASSEMBLY
     P-004-420BELL AND LIGHT CAGE P-027-946
    MANIFOLD BLOCK ONLY
     P-D-1140STROBE LIGHT, 24VP-000-805
    CHECK VALVE
     P-001-262STROBE LIGHT, 110VP-001-422
    24V DOWN SOLENOID VALVE AND COIL ASM
     P-001-259OIL IMMERSION HEATERP-000-803
    24V DOWN SOLENOID COIL ONL
    Y P-001-260BLUE SPRAY PAINT, 16 ozP-015-173
    DOWN SOLENOID VALVE 24V/115V
     P-001-279YELLOW SPRAY PAINT, 16 ozP-015-174
    115V DOWN SOLENOID AND COIL ASM
     P-001-296POWER UNIT DECAL KITP-003-868
    115V DOWN SOLENOID COIL ONL
    Y P-001-297COMPLETE DECAL KIT FOR A 1045P-004-407
    ADJUSTABLE FLOW CONTROL  P-001-265REPLACEMENT NAME/SERIAL NUMBER TAG P-001-448
    RELIEF VALVE
     P-001-263
    SUCTION LINE FILTER
     P-001-280
    VELOCITY FUSE P-001-270
    COMPLETE POWER UNIT: 
     
    115 VOLT, 1 PH, 24VA, WITH PUSHBUTTON P-004-403
    23O VOLT, 1 PH, 24VA, WITH PUSHBUTTON
     P-004-797
    230 VOLT, 3 PH, 24VA, WITH PUSHBUTTON
     P-004-798
    460 VOLT, 3 PH, 24VA, WITH PUSHBUTTON
     P-004-799 
    						
    All Advance Lifts manuals Comments (0)