Advance Lifts Dock Lifts 10451055 Manual
Here you can view all the pages of manual Advance Lifts Dock Lifts 10451055 Manual. The Advance Lifts manuals for Lift are available online for free. You can easily download all the documents as PDF.
Page 31
Section 9. Electrical Information If supplied with a 208/230/460V 3-phase motor, the connection diagrams on the outside of the motor for low voltage, 230V or high voltage, 460V. This motor connection is also rated for 208V. As any standard motor is rated for +/-10% of voltage variation, this motor will operate properly, within ratings, at 208, 220, 230, 240, 440, 460, and 480V, 3- phase supply. There are other motor configurations including single phase 115V & 230V. If you are unsure of the...
Page 32
Motor Controllers (Typical) Specifications: Motor Starter with adjustable thermal overload. 50VA transformer with 24 VAC secondary fused at 4 amps (Standard) 100VA transformer with 115 VAC secondary fused at 1.6 amps (Optional) Reset is manual or automatic (manual is standard, automatic is not to be used) Enclosure is NEMA 12 JIC supplied with (4) conduit openings (motor, down solenoid, power and push button station) Completely wired with terminal strips for final secondary...
Page 34
P9-4 X1 2 X2 1 H3 H2 4 X2 - XF X1 H4 H1 1L1 A1 6T3 4T2 2T1 6T3 4T2 2T1 5L3 3L2 96NC 97NO 98NO A2 95NC 22NC 14NO 13NO 21 NC L 1 L 2 GROUND N TO DOWN SOLENOID GROUND ADVANCE LIFTS WIRING DIAGRAM 230/460 VOLT THREE PHASE PUSH BUTTON TRANSFORMER TERMINAL STRIP MOTOR STARTER OVERLOAD BK BK BK BK BK W W W R G BK =...
Page 35
SERIES SPEED 104 5 18 00 105 5 18 00 HO RS EPOW ER APP RO X F ULL L OAD AMP S MIN COP P E R WI R E S IZ E ( 7 5 C ) THW , THHN, T HW N,X HHW CIRCUIT BRE AKE R AMPSDUAL E LE MEN T, TIM E DEL AY FUSE A MPS HORS E PO W ERAPPR OX FULL LO AD AMPSMIN CO PPE R WIRE SIZE (75C) THW ,THHN,T HW N,X HHW CIRCUIT BRE AKER A MP SDUAL EL E ME NT , TIME DELAY FUSE AMPS 1 3. 6 14 15 5.611. 814 152. 8 1-1/ 2 5. 2 14 15 81-1/22. 614 154 2 6. 8 14 15 1023. 414...
Page 38
1 2 3 4 5 6 7 SECTION 10. IDENTIFICATION AND LABEL PLACEMENT No. Qty. Location 1. (2) Centers of handrail, both sides 2. (1) Cylinder end, right side of platform 3. (4) Centered on each side of platform 4. (4) Upper vertical section of handrail 5. (2) Outer leg 6. (1 per bridge) Under bridge 7. (2) Torque tubes each end TYPICAL PLACEMENT (EACH DECAL KIT IS SUPPLIED WITH LOCATION...
Page 39
SECTION 11. TROUBLESHOOTING A. Equipment does not rise; pump is running: (see also Section M) 1. The motor rotation may be reversed. See the installation procedure on how to jog the motor to check for proper rotation. If the lift has been installed for some time and the motor is 3-phase, it is possible that the plant wiring “upstream” has been changed during plant maintenance or alteration, and the motor is now running reversed. A hydraulic pump can only run reversed for a short time...
Page 40
SECTION 11. TROUBLESHOOTING (Continued) 10. The down solenoid may be energized due to incorrect wiring, or mechanically stuck open, bypassing fluid. A. Check the wiring. Hold a non-magnetized screwdriver to the top of the down solenoid coil and press the up button. If you can feel magnetism, the wiring is faulty. B. Lightly tap the down solenoid to seat it properly. Do not bang it hard, as internal stem parts may be permanently damaged. The solenoid coil can be removed, and the down...