Adtran Atlas 800 Series Dual Video User Manual
Have a look at the manual Adtran Atlas 800 Series Dual Video User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 2 Adtran manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Appendix A. Dial Plan Interface Configuration 61200773L1-1A ATLAS 800 Series Video Module User Manual 41 The following menus are only available when the DIALING METHOD is MANUAL. REDIAL NUMBERWrite Security: 3; Read Security: 5 Activator to dial or disconnect a call to the specified number. DIAL NUMBERWrite Security: 3; Read Security: 5 Specifies the number to dial on an outgoing call. CALL TYPEWrite Security: 3; Read Security: 5 Specifies whether the data rate on the call will be 56 or 64kbps. DIAL CALL ASWrite Security: 3; Read Security: 5 Specifies the call type used to populate the Bearer Capability Information Element in the ISDN Call Setup Message. Options include: D IGITAL (Data), VOICE (speech), or A UDIO (3.1 kHz audio). SOURCE IDWrite Security: 3; Read Security: 5 Defines the source ID assigned to this call to be used for internal ATLAS routing. Source IDs simplify the creation of a dial plan in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call. MIN DS0SWrite Security: 3; Read Security: 5 This option will specify the minimum number of DS0s necessary for this switched call. If the call is negotiated and the minimum DS0s value is not met, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together. MAX DS0SWrite Security: 3; Read Security: 5 This option will specify the maximum number of DS0s allowed for this switched call. If the call is negotiated and the maximum DS0s value is not acceptable to the answering equipment, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together. STORED N UMBERS Write Security: 3; Read Security: 5 Enter the numbers to dial using the RS-366 Type II dialing interface in the stored numbers list. This list can contain up to 10 stored numbers. #Entry number (1-10).
Appendix A. Dial Plan Interface Configuration 42 ATLAS 800 Series Video Module User Manual 61200773L1-1A DIALActivator to dial or disconnect a call to the specified number. DESCRIPTIONAlphanumeric character string (up to 20 characters) used as a descriptor for the num- ber entry. Enter a useful description such as VCon5thFloor(Corp). DIGITSNumber string (up to 10 digits) to dial. TYPESpecifies whether the data rate on the call will be 56 or 64kbps. DIAL ASSpecifies the call type used to populate the Bearer Capability Information Element in the ISDN Call Setup Message. Options include: Digital (Data), Voice (speech), or Audio (3.1kHz audio). SRC IDDefines the source ID assigned to this call to be used for internal ATLAS routing. Source IDs simplify the creation of a dial plan in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call. Zero (0) is the default ID for all endpoints and all accept numbers. If all default SOURCE ID values are not modified, calls are routed based only on the dialed number. Multiple endpoints may have the same SOURCE ID. When creating the CALL AC- CEPT list, specify a SOURCE ID(s) as well as a dialed number or range of dialed numbers to accept on that endpoint. MIN DS0SThis option will specify the minimum number of DS0s necessary for this switched call. If the call is negotiated and the minimum DS0s value is not met, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together. MAX DS0SThis option will specify the maximum number of DS0s allowed for this switched call. If the call is negotiated and the maximum DS0s value is not acceptable to the answering equipment, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together. MIN INCOMING DS0 S Write Security: 3; Read Security: 5 This option will specify the minimum number of DS0s necessary for an incoming switched call to this endpoint. If the call is negotiated and the minimum DS0s value is not met, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together. MAX INCOMING DS0 S Write Security: 3; Read Security: 5 This option will specify the maximum number of DS0s allowed for an incoming switched call to this endpoint. If the call is negotiated and the maximum DS0s value is not acceptable to the answering equipment, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together.
Appendix A. Dial Plan Interface Configuration 61200773L1-1A ATLAS 800 Series Video Module User Manual 43 The following menus are only available when the DIALING METHOD is ON DTR. DIAL NUMBERWrite Security: 3; Read Security: 5 Specifies the number to dial on an outgoing call. CALL TYPEWrite Security: 3; Read Security: 5 Specifies whether the data rate on the call will be 56 or 64kbps. DIAL CALL ASWrite Security: 3; Read Security: 5 Specifies the call type used to populate the Bearer Capability Information Element in the ISDN Call Setup Message. Options include: D IGITAL (Data), VOICE (speech), or A UDIO (3.1kHz audio). SOURCE IDWrite Security: 3; Read Security: 5 Defines the source ID assigned to this call to be used for internal ATLAS routing. Source IDs simplify the creation of a dial plan in applications where the criterion for switching calls to a certain endpoint is a function of which endpoint originated the call. MIN DS0SWrite Security: 3; Read Security: 5 This option will specify the minimum number of DS0s necessary for this switched call. If the call is negotiated and the minimum DS0s value is not met, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together. MAX DS0SWrite Security: 3; Read Security: 5 This option will specify the maximum number of DS0s allowed for this switched call. If the call is negotiated and the maximum DS0s value is not acceptable to the answering equipment, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together. MIN INCOMING DS0 S Write Security: 3; Read Security: 5 This option will specify the minimum number of DS0s necessary for an incoming switched call to this endpoint. If the call is negotiated and the minimum DS0s value is not met, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together.
Appendix A. Dial Plan Interface Configuration 44 ATLAS 800 Series Video Module User Manual 61200773L1-1A MAX INCOMING DS0 S Write Security: 3; Read Security: 5 This option will specify the maximum number of DS0s allowed for an incoming switched call to this endpoint. If the call is negotiated and the maximum DS0s value is not acceptable to the answering equipment, the call will be disconnected. Any value other than 1 requires a BONDING resource to inverse multiplex the multiple switched channels together.
61200773L1-1A ATLAS 800 Series Video Module User Manual 45 Appendix BSmart Dial String Formats The Video Module accepts changes to Call Type and Channel Rate by using suffix commands appended to the end of the dial string. The following string format is used. Where #C changes the Call Type as follows: 3=56K Data 4=64K Data Where #R changes the Channel Rate (number of ISDN B channels) as follows: 1=1 B Channel (1x56k, 1x64k) 2=2 B Channel (2x56k, 2x64k) BONDING Mode 1 3=3 B Channel (3x56k, 3x64k) BONDING Mode 1 . . . 23=23 B Channel (23x56k, 23x64k) BONDING Mode 1 Where #S changes the Source ID (valid range 0-9) to route the call through the Dial Plan. The following are dialing examples: BONDING 384k using 64K call type (6x64k) 7082906055#4#6#0 BONDING 336k using 56K call type (6x56k) 7082906055#3#6#0 BONDING 256k using 64K call type (4x64k) 7082906055#4#4#0 BONDING 256k using 64k call type (4x64k) 7082906055#4#4#5 with Source ID 5
Appendix B. Smart Dial String Formats 46 ATLAS 800 Series Video Module User Manual 61200773L1-1A If no suffix is used, the call is placed using the values configured for the Video Module. For example, if the Dual Video Module is configured with D EFAULT CALL T YPE = 64k digital data, SOURCE ID = 0, DEFAULT MIN DS0S = (2, 3, 4, 5, or 6), and D EFAULT MAX DS0S = 6, the dial string 7082906055 is the same as 7082906055#4#6#0. If the Channel Rate suffix is used, the Call Type suffix is required. However, the Channel Rate is not required to make changes to the Call Type. For example, if the Video Module defaults configure the port for 384k Call Type, only the #3 suffix is required to change the Call Type to 336k. The dial string 7082906055#3 is the same as 7082906055#3#6. If the Source ID suffix (#S) is used, both the Call Type (#C) and the Channel Rate (#R) Suffixes are required. However, the Source ID suffix (#S) is not required to make changes to the Call Type or Channel Rate. For example, if the Video Module defaults configure the port for 384k (6x64k) on Source ID=0, only the #3 and #8 suf- fixes are required to change the call type to 448k. The dial string 7082906055#3#8 is the same as 7082906055#3#8#0.
61200773L1-1A ATLAS 800 Series Video Module User Manual 47 Appendix CVideo Module Menu Tree Figure C-1. ATLAS 800 Series Video Module Menu Tree Info Part Number Serial Number Board Revision Slt Video Menu SLIP Type Alarm Status Port PLL Modules Menu Module Alarms (shortcut)Alarms Zero Alarm No Ext Clk Test DTE Status Port State DTE Status RTS Rev CTS Port Data Rate Port DTR Name Rate DSR Clk + / - Normal DCD Inverted RI Data Normal TD Inverted RD LOCK CTS Normal PLL Fifo Port EC RXE Forced On PLL/Fifo RXF DCD Normal TXE Forced On TXF DSR Normal ConfigurationForced On DTR Ignore DTR Recognize DTR Test Activity Port No Loopback 0 Inh Off Test Loopback Local Loopback On (shortcut)Loopback Status 511ON OFF 511 Results Sync Y Clr ES N Inject EIA Prt AUTO DTE Interface DTE Interface Mode EIA-530 V. 3 5 Current DTE Type RS-449 Loopback
Appendix C. Video Module Menu Tree 48 ATLAS 800 Series Video Module User Manual 61200773L1-1A
61200773L1-1A ATLAS 800 Series Video Module User Manual 49 Index A alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 ATLAS menus F ACTORY RESTORE . . . . . . . . . . . . . . . . . . . . . 35 R UN SELFTEST . . . . . . . . . . . . . . . . . . . . . . . . 35 D Data Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Dial Smart String . . . . . . . . . . . . . . . . . . . . . . . . . . 45 D IAL PLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Dialing Method . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 DTE Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 E EIA-530 connector pinout . . . . . . . . . . . . . . . . . . . 24 F features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 I initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 installing the module . . . . . . . . . . . . . . . . . . . . . . . 22 preliminary steps . . . . . . . . . . . . . . . . . . . . . . 21 M Menu Call Type . . . . . . . . . . . . . . . . . . . . . . . . . 41, 43 Default Call Type . . . . . . . . . . . . . . . . . . . . . . 39 Default Dial Call As . . . . . . . . . . . . . . . . . . . . 40 Default Max DS0s . . . . . . . . . . . . . . . . . . . . . 40 Default Min DS0s . . . . . . . . . . . . . . . . . . . . . . 40 Default Source ID . . . . . . . . . . . . . . . . . . . . . . 40 Dial After . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Dial Call As . . . . . . . . . . . . . . . . . . . . . . . 41, 43 Dial Number . . . . . . . . . . . . . . . . . . . . . . . 41, 43 Max DS0s . . . . . . . . . . . . . . . . . . . . . . . . . 41, 43 Max Incoming DS0s . . . . . . . . . . . . . . 40, 42, 44 Min DS0s . . . . . . . . . . . . . . . . . . . . . . . . . 41, 43 Min Incoming DS0s . . . . . . . . . . . . . . 40, 42, 43 Redial Number . . . . . . . . . . . . . . . . . . . . . . . . 41Source ID . . . . . . . . . . . . . . . . . . . . . . . . . 41, 43 Stored Numbers . . . . . . . . . . . . . . . . . . . . 39, 41 Menu Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 M ODULES menus and submenus . . . . . . . . . . . . . . 28 A LARMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 M ENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 See also, M ODULES/MENU. R EV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 S LT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 S TATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 S TATUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 T EST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 T YPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 M ODULES/MENU . . . . . . . . . . . . . . . . . . . . . . . . . . 30 A LARM STATUS . . . . . . . . . . . . . . . . . . . . . . . . 30 B OARD REVISION . . . . . . . . . . . . . . . . . . . . . . 30 C ONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . 32 DTE S TATUS . . . . . . . . . . . . . . . . . . . . . . . . . . 31 I NFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 M ODULE ALARMS . . . . . . . . . . . . . . . . . . . . . . 35 P ART NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . 30 S ERIAL NUMBER . . . . . . . . . . . . . . . . . . . . . . . 30 T EST ACTIVITY . . . . . . . . . . . . . . . . . . . . . . . . 35 O operation overview . . . . . . . . . . . . . . . . . . . . . . . . . 27 P pinout network connection . . . . . . . . . . . . . . . . . . . . . 23 RS-366 Interface . . . . . . . . . . . . . . . . . . . . . . . 26 PLL/FIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 power up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 R RS-366 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 RS-366 Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 RS-449 pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Index 50 ATLAS 800 Series Video Module User Manual 61200773L1-1A S self test, failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 self-test failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 shipping contents . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Smart Dial Call Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Channel rate . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Source ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 interface types . . . . . . . . . . . . . . . . . . . . . . . . . 18 line rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 RS-366 dialing interface . . . . . . . . . . . . . . . . . 18 tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 T terminal menu structure . . . . . . . . . . . . . . . . . . . . . 27 U USER TERMINATION . . . . . . . . . . . . . . . . . . . . . . . . 38 V V.35 Winchester pinout . . . . . . . . . . . . . . . . . . . . . 23 video module features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 functional description . . . . . . . . . . . . . . . . . . . 17 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 physical description . . . . . . . . . . . . . . . . . . . . . 19 W wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23