–11– (continued) SECURITY CODES To Assign, Change, or Delete User Codes4-DIGIT USER CODESIt is recommended thatobvious codes such as1111 or 1234 not beassigned. 1. Enter your Master code and press the CODE key. 2. Enter single-digit user number (2, 3, 4, 5, 6 or 7) for which a code is to be assigned, changed, or deleted. 3. If assigning or changing a users code, enter the desired 4-digit code for use by that user number. The keypad will beep once. If deleting a users code, perform steps 1 & 2 and stop. In a few moments the keypad will beep once, indicating that the existing code has been deleted. To assign your Duress code, do the following: Enter your [Master code] + [8] + [8] + [desired 4-digit code]. The keypad will beep once. The Master code can be changed by the main user of the system. To change it, do the following: Enter your [Master code] + [8] + [1] + [new Master code] + [new Master code] again. The keypad will beep once. Important:Temporary users should not be shown how to use any system function they do not need to know (e.g., bypassing protection zones).
–12– ENTRY/EXIT DELAYS General Information Your system has preset time delays, known as exit delay and entry delay. When you arm your system, exit delay gives you time to leave through the entry/exit door without setting off an alarm. Entry delay gives you time to disarm the system when you reenter through the entry/exit door. The system must be disarmed, however, before the entry delay period ends, or an alarm will occur. The keypad will beep slowly during the entry delay period, reminding you to disarm the system. You can also arm the system with no entry delay at all by using either INSTANT or MAXIMUM arming modes. These modes can provide greater security while you are sleeping or while you are away for extended periods of time. See your installer for your delay times and record them here: Exit Delay: secondsEntry Delay: seconds
–13– CHECKING FOR OPEN ZONES Using the T READY KeyBefore your system can be armed, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING PROTECTION ZONES section), otherwise the keypad will display a Not Ready message, and if your keypad has a READY indicator light, it will not be lit. The READY key can be used to display all faulted zones, making it easier for you to secure any open zone. To display faulted zones, simply press and release the READY key (do not enter code first). Secure or bypass the zones displayed before arming the system. A Ready message will be displayed when all protection zones have been either closed or bypassed and the keypads READY indicator light (if present) will be lit. TYPICAL DISPLAYS TYPICAL DISPLAYSINDICATING FAULTED PROTECTION ZONETYPICAL DISPLAYS WHEN NOT READY TO ARM (AFTER PRESSING READY KEY) INDICATING READY TO ARM ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER 03 ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER
–14– BYPASSING PROTECTION ZONES Using the 6 BYPASS KeyLIMITATION The system will notallow fire zones to bebypassed. All bypasses are removedwhen an OFF sequence(security code plus OFF)is performed. This key is used when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first. 1. Enter your security code and press the BYPASS key. 2. Enter zone number(s) for the zone(s) to be bypassed (e.g., 06, 10, 13, etc.). Single digit zone numbers must be preceded by a zero (e.g. 05, 06) . 3. When finished, the keypad will display a Bypass message along with each bypassed zone number, accompanied by a beep for each. Wait for these zones to be displayed, to confirm their bypass. 4. Arm the system as usual. Bypassed zones are unprotected and will not cause an alarm if violated while your system is armed. TO BYPASS ZONES:• ENTER USER CODE.• PRESS BYPASS KEY.• ENTER ZONE Nos.• WAIT FOR BYPASSED ZONES TO BE DISPLAYED.• ARM BURGLARY PROTECTION AS USUAL. TYPICAL MOMENTARY DISPLAYS OF BYPASSED ZONEALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER 03 FIXED-WORD
–15– (continued) BYPASSING PROTECTION ZONES Quick BypassAsk your installer ifQuick Bypass isactive for yoursystem, and if so,check here: If your system supports Quick Bypass, it allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. To use this feature, enter your security code, press the BYPASS key, then stop. In a few moments, all open zones will be displayed along with a Bypass message. Wait for all bypassed zones to be displayed, then arm the system as usual.BURGLARY PROTECTIONCAN NOW BE ARMEDWITH ZONE(S) BYPASSED. TYPICAL DISPLAYS READY TO ARM WITH ZONES BYPASSED ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER FIXED-WORD
–16– ARMING PERIMETER ONLY WITH ENTRY DELAY ON Using the 3 STAY Key BEFORE ARMING close all doors and windows(see CHECKING FOR OPEN ZONES on page 13). Use this key when you are staying inside, but expect someone to use an entry/exit door later. 1. Enter your security code and press the STAY key. 2. The keypad will beep three times and will display the armed message. The red ARMED indicator will light. 3. The system will arm. An alarm will sound immediately if a protected perimeter window or non-entry/exit door is then opened, but you may otherwise move freely throughout the premises. Later arrivals can enter through an entry/exit door without causing an alarm, but they must disarm the system within the entry delay period to avoid sounding an alarm.USER CODE + STAY KEYARMS THE PERIMETER,BUT ALLOWS USE OFTHE ENTRY/EXIT DOOR. TYPICAL DISPLAYS ARMED STAY ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER FIXED-WORD
–17– ARMING PERIMETER ONLY WITH ENTRY DELAY OFF Using the 7 INSTANT Key BEFORE ARMING close all doors and windows(see CHECKING FOR OPEN ZONES on page 13). Use this key when you are staying inside and do not expect anyone to use an entry/exit door. 1. Enter your security code and press the INSTANT key. 2. The keypad will beep three times and will display the armed message. The red ARMED indicator will light. 3. The system will arm. An alarm will sound immediately if any protected perimeter door or window is then opened, but you may otherwise move freely throughout the premises. An alarm will sound immediately if anyone opens an entry/exit door.USER CODE + INSTANT KEYARMS THE PERIMETER(INCLUDING THE ENTRY/EXIT DOOR),WITH NO ENTRY DELAY. TYPICAL DISPLAYS ARMED INSTANT ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER FIXED-WORD
–18– ARMING ALL PROTECTION WITH ENTRY DELAY ON Using the 2 AWAY Key BEFORE ARMING close all doors and windows(see CHECKING FOR OPEN ZONES on page 13). Use this key when no one will be staying inside. 1. Enter your security code and press the AWAY key. 2. The keypad will beep twice and will display the armed message. The red ARMED indicator will light. 3. You may leave through an entry/exit door during the exit delay period without causing an alarm. After exit delay, the system arms and will sound an alarm if a protected window or non-entry/exit door is then opened, or if any movement is detected inside your premises. You may reenter through an entry/exit door, but must disarm the system within the entry delay period to avoid an alarm.USER CODE + AWAY KEYARMS ALL BURGLARY PROTECTION(INTERIOR AND PERIMETER),BUT ALLOWS USE OF THEENTRY/EXIT DOOR. TYPICAL DISPLAYS ARMED AWAY ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER FIXED-WORD
–19– ARMING ALL PROTECTION WITH ENTRY DELAY OFF Using the 4 MAXIMUM Key BEFORE ARMING close all doors and windows(see CHECKING FOR OPEN ZONES on page 13). Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when no one will be moving through protected interior areas. 1. Enter your security code and press the MAXIMUM key. 2. The keypad will beep twice and will display the armed message. The red ARMED indicator will light. 3. You may leave through an entry/exit door during the exit delay period without causing an alarm. After exit delay, the system arms and will sound an alarm immediately if any protected door or window is opened, or if any movement is detected inside your premises. An alarm will sound immediately, when someone reenters.USER CODE + MAXIMUM KEYARMS ALL BURGLARY PROTECTION(INTERIOR AND PERIMETER),(INCLUDING THE ENTRY/EXIT DOORWITH NO ENTRY DELAY). TYPICAL DISPLAYS ARMED MAXIMUM ALARM AWAYBYPASSSTAY SUPV NO AC PHONE TEST NOT READY CHIME BAT FIRE CHECK INSTANT TAMPER FIXED-WORD
–20– DISARMING THE SYSTEM AND SILENCING ALARMS Using the 1OFF Key IMPORTANT: If you return and themain burglary sounder is on: DO NOT ENTER, butCONTACT THE POLICEfrom a nearby safe location.If you return after analarm has occurred and the main sounderhas shut itself off:the keypad will beep rapidlyupon your entering, indicatingthat an alarm has occurred during your absence (the Memory of Alarm feature).LEAVE IMMEDIATELY, andCONTACT THE POLICEfrom a nearby safe location.WHEN SAFE TO DO SO, re-enter and follow the procedurefor silencing an alarm. The OFF key is used to disarm the system and to silence alarm and trouble sounds. To Disarm the System Enter your security code and press the OFF key. The Ready message will be displayed, and the keypad will emit a single tone to confirm that the system is disarmed. To Silence a Burglary Alarm SEE IMPORTANT NOTE AT LEFT! Enter your security code and press the OFF key to silence the alarm (or warning tones of a Memory of Alarm). Note the zone in alarm on the keypad display, and make that zone intact (close door, window, etc.). Now enter the security code plus OFF sequence again to clear the keypads Memory of Alarm display. If the display will not clear and does not provide a Ready message, notify the alarm agency. To Silence a Fire Alarm simply press the OFF key (the security code is not needed to silence FIRE alarms). To then clear the keypads Memory of Alarm display, enter your security code and press the OFF key. See page 29 for additional fire alarm information. See the SUMMARY OF AUDIBLE/VISUAL NOTIFICATION section for information which will help you to distinguish between FIRE (Interrupted/Pulsed) and BURGLARY (Continuous/Steady) alarm sounds.