AboutThis page displays key information about the TX unit that may be requested by Adder Technical Support.
To get here1 Connect your computer to a port on the front panel.
2 Run a web browser and enter the IP address of the Management (ALIF dual only) or System port used: http://192.168.1.42 (management port) or http://169.254.1.33 (system port) If the address is unknown, perform a manual factory reset.
3 Click  the About link.   

Page 32

31
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
APPENDIX B - Receiver (RX) unit configuration pages
This section covers the browser-based configuration utility for the AdderLink Infinity RX 
(receiver) unit. The RX utility has nine pages, titled as follows:
• System Configuration • Statistics
• USB Settings  • Firmware Upgrade  
• Security  • Reboot 
• AIM Manager • About
• System Messages   

Page 33

32
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
Unit NameName details that you can alter to distinguish this unit from all others. 
Unit DescriptionAllows you to add a description of the unit, such as its location. Useful when many ALIF units are being used.
System portThis section determines the IP address, netmask and gateway details for the main Gigabit Ethernet port located on the right side of the front panel.  The default IP address is 169.254.1.32 which is the zero config IP...

Page 34

33
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
RX System Configuration (2 of 2)
Target Transmitter Unit Settings This section is where you configure the IP address details of the ALIF transmitter(s) that this receiver will connect with. You can quickly set all peripheral feeds (video 1/2, audio, USB and serial) to use the same primary (and secondary) locations using the IP Address (System port) and IP Address  2 (Teaming port) entries. 
For normal one-to-one connections enter the IP...

Page 35

34
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
RX USB Settings 
Allow Human Interface Devices (HID) onlyWhen enabled, this option restricts supported USB devices to keyboards and mice only. The use of memory sticks and other devices will be disabled. 
Isochronous Endpoint OSD AlertsThe ALIF USB system does not support Isochronous USB. When enabled, this option will alert the user when an Isochronous USB device is connected. 
Enable Isochronous Endpoint AttachWhen enabled, this option...

Page 36

35
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
RX Security 
EncryptionThis setting allows you to apply encryption to the USB and control data passed across the link. Note that video data is never encrypted. 
Secure Web pages with password When ticked, this option enables https security so that the configuration pages are only accessible to the admin user with a password.
Change/confirm passwordThese options allow you to change the admin password for the system. 
To get here1 Connect...

Page 37

36
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
RX AIM  Manager 
Enable AIM  ControlClick this button to allow an A.I.M. (Adder Infinity Manager) box to take control of this RX. When the button is clicked, the RX unit will be rebooted to allow the A.I.M. box to discover and control it.
RX System Messages 
To get here1 Connect your computer to a port on the front panel.
2 Run a web browser and enter the IP address of the Management (ALIF dual only) or System port used: http://192.168.1.42...

Page 38

37
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
RX Statistics 
RX Firmware Upgrade
RX Reboot
UpgradeUse this page to upgrade the main or backup firmware image on the unit. Please see the section Performing an upgrade for details.
Reboot Use this page to perform a reboot or a factory reset. Please see the section Manual factory reset for details.
Enable collection of bandwidth statisticsThe ALIF unit can record data transfer statistics from the System port and plot them on a graph for...

Page 39

38
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
RX About 
AboutThis page displays key information about the RX unit that may be requested by Adder Technical Support.
To get here1 Connect your computer to a port on the front panel.
2 Run a web browser and enter the IP address of the Management (ALIF dual only) or System port used: http://192.168.1.42 (management port) or http://169.254.1.32 (system port) If the address is unknown, perform a manual factory reset.
3 Click  the About link.   

Page 40

39
INSTALLATION
CONFIGURATION
OPERATION
FURTHERINFORMATION
INDEX
APPENDIX C - Tips for success when networking ALIF units
ALIF units use multiple strategies to minimize the amount of data that they send 
across networks. However, data overheads can be quite high, particularly when very 
high resolution video is being transferred, so it is important to take steps to maximize 
network efficiency and help minimize data output. The tips given in this section have been 
proven to produce very beneficial...
Start reading ADDERLink INFINITY dual Manual v30

Related Manuals for ADDERLink INFINITY dual Manual v30

All ADDER manuals