ADDERLink DV104T Manual
Here you can view all the pages of manual ADDERLink DV104T Manual. The ADDER manuals for Extender are available online for free. You can easily download all the documents as PDF.
Page 11
10 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Receiver connections Connections to the receivers are made using standard shielded twisted pair network cables of Category 6 (S/STP or S/FTP) or better. The use of shielded cables is important to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances. For best results, Adder recommends S/FTP CAT7 cable such as Adder part number VSCAT7-50. The...
Page 12
11 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Power adapter connection IMPORTANT: Please read and adhere to the electrical safety information given within the Safety information section of this guide. In particular, do not use an unearthed power socket or extension cable. To connect the power adapter 1 Attach the output connector of the power adapter (country specific power supplies are available) to the power input socket on the left side of the rear panel. From power adapter 2...
Page 13
12 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Configuration INITIAL CONFIGURATION The configuration, monitoring and management of the ALDV104T transmitter and its receivers is performed using the in-built AdderLink POD Manager (POD = Proof Of Display) which is accessible via the network connection using a standard web browser. Accessing the AdderLink POD Manager To access the AdderLink POD Manager 1 Use a computer that is directly or indirectly (i.e. via a network switch) connected...
Page 14
13 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Using the AdderLink POD Manager The browser-based AdderLink POD Manager allows you to configure, monitor and manage all aspects of the installation. The System Overview is the first page to be displayed and provides a graphical overview of the installation as sensed by the transmitter: System Overview elements HDMI Inputs The line appearance and number colors indicate the status of the two HDMI inputs: Both HDMI inputs active. One...
Page 15
14 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Receiver configuration Within the AdderLink POD Manager you can access the configuration page for any receiver in either of two ways: • Click the Receiver Configuration button and then click the required Po r t number entry, or • In the System Overview, click the appropriate screen image. The configuration page will be displayed: The page includes the following: • An Identify button that will cause the connected receiver to identify...
Page 16
15 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX Transmitter configuration Within the AdderLink POD Manager you can access the Transmitter configuration page in either of two ways: • Click the Transmitter Configuration button, or • In the System Overview, click the transmitter image. The configuration page will be displayed: In this page you can: • Determine the operation mode and how the various receivers and their screens are allied with the HDMI input(s), • Choose which screen...
Page 17
16 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX To choose the screen configurations used to inform the HDMI sources Before an HDMI source can provide video output it needs to be informed about the capabilities and requirements of the attached screens. The AdderLink POD Manager lets you choose from three different EDID (Extended Display Identification Data) sources: • Default - A standard EDID retained by the transmitter will be used. • Cloned and Transparent - Both of these options...
Page 18
17 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX System configuration Within the AdderLink POD Manager click the System Configuration button to display the System configuration page: In this page you can: • Configure access details for the network port, • Manage authorized users and their access passwords, • Check and upgrade the firmware contained within the transmitter and/or any receiver units connected to it. To configure access details for the network port 1 Access the AdderLink...
Page 19
18 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX To manage authorized users and their passwords 1 Access the AdderLink POD Manager. 2 On the left side, click the System Configuration button. 3 Click the User Accounts option. The following page will be displayed: 4 To add or edit a user, select one of the six user locations and then click the Edit User button to display the following options Ü 5 Enter/edit the required Username and Password. • Usernames and passwords can consist of up...
Page 20
19 INSTALLATION CONFIGURATION OPERATION FURTHERINFORMATION INDEX In operation, most AdderLink DV installations require no intervention once configured. The transmitter unit takes care of all connection control behind the scenes and AdderLink POD Manager provides suitable management tools for remote monitoring. MANAGING THE INSTALLATION The AdderLink POD Manager provides a clear and intuitive overview of the installation that allows you to take swift action if necessary. To display the System...