    							The Adder C-USB modules allow you to extend the distance between a USB p\
    eripheral and your computer by up to 100 meters.  
    The local module connects to a vacant USB port on your computer. You the\
    n connect your USB 1.1 or 2.0 peripheral to the remote module which is linked via CAT5e, 6 or 7 cablin\
    g (not supplied) to the local module. A power adapter is provided to supply either the local or remote module,\
     whichever is most convenient.
    In operation, the C-USB modules remain transparent to allow your USB per\
    ipheral to work as expected.
    C-USB cable extenders 
    Quick Start
    Safety information
    •	 For	use	in	dry,	oil	free	indoor	environments	only.
    •	 Do	not	use	to	link	between	buildings.
    •	 Not	suitable	for	use	in	hazardous	or	explosive	environments or next to highly flammable materials.
    •	 Warning	–	the	power	adapter	contains	live	parts.
    •	 No	user	serviceable	parts	are	contained	within	the	modules or the power adapter - do not dismantle.
    •	 Do	not	use	the	power	adapter	if	the	power	adapter	case	becomes	damaged,	cracked	or	broken	or	if	you	suspect that it is not operating properly.
    •	 Replace	the	power	adapter	with	a	manufacturer	approved type only. 
    •	 If	you	use	a	power	extension	cable	with	the	power	adapter,	make	sure	the	total	ampere	rating	of	the	devices plugged into the extension cable do not exceed either	the	cable’s	ampere	rating	or	that	of	the	wall	outlet.
    •	 Ensure	that	all	twisted	pair	interconnect	cables	are	installed in compliance with all applicable wiring regulations. 
    •	 Do	not	connect	the	CATx	link	interface	(RJ45	style	connector) to any other equipment, particularly network or telecommunications equipment.
    •	 Where	possible,	avoid	laying	the	twisted	pair	link	cable(s) alongside power cables. 
    •	 The	modules	do	not	provide	ground	isolation	and	should	not	be	used	for	any	applications	that	require	ground isolation or galvanic isolation.
    Warranty
    Adder Technology Ltd warrants that this product	shall	be	free	from	defects	in	workmanship	and	materials	for	a	period	of	two	years	from	the	date	of	original	purchase.	If	the	product	should	fail	to	operate	correctly	in normal use during the warranty period, Adder	will	replace	or	repair	it	free	of	charge.	No	liability	can	be	accepted	for	damage	due	to misuse or circumstances outside Adder’s control. Also Adder will not be responsible for	any	loss,	damage	or	injury	arising	directly	or	indirectly	from	the	use	of	this	product.	Adder’s	total	liability	under	the	terms	of	this	warranty shall in all circumstances be limited to	the	replacement	value	of	this	product.	If	any	difficulty	 is	experienced	 in	the	 installation	or	use	of	this	product	that	you	are	unable	to	resolve, please contact your supplier.
    Local Module
    Supplied items
    Remote Module
    Power adapter and power cord
    ©	2013	Adder	Technology	Limited	•	All	trademarks	are	acknowledged.	
    Part	No.	MAN-CUSBEXT100-QS-ADDER	•	Release	2.0a 
    Web:		www.adder.com
    Contact:		www.adder.com/contact-details
    Support:	forum.adder.com
    USB link cable 
    Green indicator
    CUSBEXT100
    Mounting slots for use with cable ties 
    						
    							Link cable
    Use only CAT 5e or better twisted pair cabling to a total length no greater than 100 meters. 
    Host computer USB connection
    Use the supplied USB cable to link the local module to a vacant port on your computer.
    Local module
    Remote 
    moduleUSB device connection
    Connect	the	plug	of	your	USB	device	to the socket on the remote module.
    Checking the installation
    On the local and remote modules, check that their green indicators are o\
    n. The green indicators signify	that	the	modules	are	powered	up;	have	a	USB	connection	to	your	system	and	are	joined	by	a	suitable link cable.   
    If	the	green	indicators	are	not	on,	check	the	three	key	items	mentioned	above.
    If	the	green	indicators	are	flashing,	either	the	link	cable	is	faulty	or	there	may	be	a	mismatch	between	the	firmware	held	within	the	modules.	Contact	Adder	technical	support	for	assistance.	
    Power adapter
    Once	connected	to	one	of	the	modules,	use	the	supplied	power	cord	to	join	the	power	adapter	with	the	nearest	wall outlet.
    Connect the power adapter to the power jack	on	either	module.
    Note
    Never	connect	power	adapters	to	the	local	and	remote modules simultaneously as this may cause permanent damage to one or both modules. 
    						