    Quick Start
    Safety information
    •	 For	use	in	dry,	 oil	free	 indoor	 environments	 only.
    •	 Do	not	use	to	link	between	buildings.
    •	 Not	suitable	for	use	in	hazardous	or	explosive	environments	or	next	to	highly	flammable	materials.
    •	 Ensure	that	all	twisted	pair	interconnect	cables	are	installed	in	compliance	with	all	applicable	wiring	regulations.	
    •	 Do	not	connect	the	CATx	link	interface	(RJ45	style	connector)	to	any	other	equipment,	particularly	network	or	telecommunications	equipment.
    •	 Where	possible,	avoid	laying	the	twisted	pair	link	cable(s)	alongside	power	cables.	
    •	 Warning	–	the	power	adapter	contains	live	parts.
    •	 No	user	serviceable	parts	are	contained	within	the	power	adapter	-	do	not	dismantle.
    •	 The	primary	means	to	cease	operation	of	the	modules	is	to	remove	the	power	adapter	lead.	Ensure	that	the	power	adapter	is	positioned	near	to	the	equipment	and	is	easily	accessible.
    •	 Do	not	use	the	power	adapter	if	the	power	adapter	case	becomes	damaged,	cracked	or	broken	or	if	you	suspect	that	it	is	not	operating	properly.
    •	 Replace	the	power	adapter	with	a	manufacturer	approved	type	only.	
    •	 If	you	use	a	power	extension	cable	with	the	modules,	make	sure	the	total	ampere	rating	of	the	devices	plugged	into	the	extension	cable	do	not	exceed	the	cable’s	ampere	rating.	Also,	make	sure	that	the	total	ampere	rating	of	all	the	devices	plugged	into	the	wall	outlet	does	not	exceed	the	wall	outlet’s	ampere	rating.
    •	 Do	not	attempt	to	service	the	modules	yourself.
    •	 The	modules	and	power	supplies	can	get	warm	in	operation	–	do	not	situate	them	in	an	enclosed	space	without	any	ventilation.	
    •	 The	modules	do	not	provide	ground	isolation	and	should	not	be	used	for	any	applications	that	require	ground	isolation	or	galvanic	isolation.
    •	 Use	only	with	grounded	outlets	at	both	the	computer	and	monitor.	When	using	a	backup	power	supply	(UPS),	power	the	computer,	the	monitor	and	the	module	from	the	same	supply.
    •	 For	correct	operation,	the	transmitter	and	receiver	modules	must	have	ground	connections.	At	the	computer	end,	this	is	achieved	by	ensuring	that	the	computer	that	the	module	is	connected	to	has	a	ground	connection.	At	the	audio/visual	device	end,	this	can	be	achieved	by	ensuring	that	the	power	supply	is	connected	to	a	grounded	power	outlet.	Alternatively,	a	ground	connection	will	be	made	via	the	monitor,	if	the	monitor	is	itself	grounded.
    Warranty
    Adder	Technology	Ltd	warrants	that	this	product	shall	be	free	from	defects	in	workmanship	and	materials	for	a	period	of	two	years	from	the	date	of	original	purchase.	If	the	product	should	fail	to	operate	correctly	in	normal	use	during	the	warranty	period,	Adder	will	replace	or	repair	it	free	of	charge.	No	liability	can	be	accepted	for	damage	due	to	misuse	or	circumstances	outside	Adder’s	control.	Also	Adder	will	not	be	responsible	for	any	loss,	damage	or	injury	arising	directly	or	indirectly	from	the	use	of	this	product.	Adder’s	total	liability	under	the	terms	of	this	warranty	shall	in	all	circumstances	be	limited	to	the	replacement	value	of	this	product.	If	any	difficulty	is	experienced	in	the	installation	or	use	of	this	product	that	you	are	unable	to	resolve,	please	contact	your	supplier.
    For each module: Power supply adapter and country-specific mains cable
    Self adhesive rubber feet
    RECEIVER
    BRIGHTSHARP
    100
    ADDERLINK
    OUTOUT
    TRANSMITTER
    ADDERLINK
    ININ
    100
    AdderLink AV transmitter*AdderLink AV receiver*
    * AdderLink AV100 and AV200 models are both packaged as transmitter and receiver pairs. AV104, AV101, AV100R and AV100T modules are packaged separately.  
    Serial cableAdder P/N: CAB-9M/9F-2M
    Video cableAdder P/N: VSC18 
    What you may additionally need
    Stereo audio cableAdder: P/N VSC22 
    What’s in the box
    Connection overview inside
    Full	user	guide	available	at	www.adder.com©	2012	Adder	Technology	Limited	•	All	trademarks	are	acknowledged.	
    Part	No.	MAN-ALAV-QUICK	•	Release	1.1c 
    Web:		 www.adder.com
    Contact:		www.adder.com/contact-details
    Support:	forum.adder.com 
    						
    							Video input
    from PC
    Optional outputto
    local video monitor
    Powerinput
    CA Tx link connections
    to receivers 2, 3and 4
    (A V104 models only)
    Audioinput
    from PCOptional outputto
    local speakers
    CATx link upto300m (1000
    feet)
    Audio output
    to speakers
    Audiooutput
    to speakers
    V
    ideo output
    to display
    Video output
    to display
    Power
    input
    Optional linkoutput to
    a cascaded receiver
    (A V101 models only)
    TRA N SM IT TER
    LI NK 2
    LI NK 3
    LI NK 4
    10 4
    ADDERLINK
    IN
    IN
    REC EIV ER
    SK EW
    G BSK EW
    R GB RIG HTSH ARP
    LINK OUT
    101
    ADDERLIN K
    OUT
    OUT
    Connection overview
    •	 For	full	explanations	of	connections,	including	cascade	connections,	please	refer	to	the	full	user	guide	available	at www.adder.com.
    •	 Please	consult	the	Safety	information	on	the	rear	page	of	this	quick	start	guide.
    Locations
    Please	consider	the	following	important	points	when	planning	the	positions	of	your	AdderLink	AV	modules:
    •	 Take	care	not	to	exceed	the	maximum	link	cable	lengths	(please	refer	to	the	section	‘Making	cascade	connections’	in	the	main	user	guide	for	a	full	explanation).	
    •	 Ensure	that	the	transmitters	are	as	close	as	possible	to	the	source	PC	system	and	the	receivers	are	similarly	close	to	the	display	modules.	Use	video	connection	cables	that	are	correctly	shielded	and	are	no	longer	than	6m	in	length.	
    •	 Wherever	possible,	choose	routes	for	the	CATx	twisted	pair	link	cables	that	avoid	mains	power	cables.	
    •	 Remember	a	mains	power	socket	is	required	for	each	transmitter	and	receiver.
    Resolutions and cable lengths
    The	maximum	resolutions	achievable	are:	1600	x	1200	x	60Hz	at	200m	and	1280	x	1024	x	60Hz	at	300m.	If	you	are	using	lower	resolutions	then	it	may	be	possible	to	achieve	longer	transmission	distances	although	we	do	not	recommend	runs	longer	than	300m	in	any	installation.	If	you	are	running	shorter	cables	then	it	may	be	possible	to	use	more	cascades.
    Adjustments	for	skew	compensation	between	colours	(AV101	and	AV200	models	only)
    Brightness	adjustment	dial
    Sharpness	adjustment	dial 
    						