20 Operation In operation, the AdderLink AV modules are designed to be as transparent - high quality video and audio signals from the source PC system are distribute\ d to the various display units and control signals are similarly routed back to t\ he system. Indicators All AdderLink AV modules are equipped with two indicators to confirm operation and, if necessary, assist with quick troubleshooting of potent\ ial problems. The...
Page 22
21 Serial port switching The AdderLink AV204T and AV208T modules use a sophisticated switching system to extend the ordinarily point-to-point nature of serial communic\ ations across a network of connected display units. The AdderLink system allows\ you to communicate with any display individually or to broadcast commands ac\ ross the network as a whole. When switching to a single display, it is then p\ ossible to receive responses back...
Page 23
22 Adjustments The AV200R and AV201R receivers both include brightness and sharpness adjustment dials. Additionally, the AV201R receiver is also equipped wit\ h two extra dials to eliminate the effects of colour skew within the video ima\ ge. Brightness and sharpness adjustments The brightness and sharpness adjustments provided on every AV receiver allow you to compensate for any losses incurred within long cable links. When making...
Page 24
23 Skew compensation adjustments (AV201R only) The twisted pair cabling used to link the AV modules consists of four pairs of wires per cable. Three of these pairs are used to convey the red, green and blue video signals. Due to slight differences in twist rate between the wire pairs, the red, green and blue video signals may not arrive at precisely the same time. This effect is visible as separate colour shadows on high contrast...
Page 25
24 To zero the skew adjustment dials When supplied, the two skew dials are set in their neutral positions. i.e. no delay to either of its colours. However, if the module has been previously used and adjusted then you may need to relocate the zero point. There are no setting markers around the two skew dials and the dial itself does not have a pointer. 1 Insert a small screwdriver into the skew dial and twist it all the way...
Page 26
25 Upgrading The internal software (firmware) of the AV204T and AV208T transmitte\ rs can be upgraded in order to take advantage of a continual process of improvemen\ t and innovation. The supplied serial cable is required to connect the AV204T/\ AV208T module to the serial port of a suitable system. Note: It is not possible to alter the firmware within the AV200T trans\ mitter or the AV200R/AV201R receivers. The operation of these modules...
Page 27
26 Further information Troubleshooting If you experience problems when installing or using the AdderLink AV modules, please check through this section for a possible solution. If your problem is not listed here and you cannot resolve the issue, then please refer to the ‘\ Getting assistance’ section. No video image is received at the receiver module. • Check that the both the red power indicators are lit on both the transmitter and...
Page 28
27 Safety information • For use in dry, oil free indoor environments only. • Do not use to link between buildings. • Not suitable for use in hazardous or explosive environments or next to highly flammable materials. • Ensure that all twisted pair interconnect cables are installed in compliance with all applicable wiring regulations. • Do not connect the CATx link interface (RJ45 style connector) to any other equipment, particularly...
Page 29
28 Products in the AdderLink AV200 range The following items are available within the AdderLink AV200 product ran\ ge: • AdderLink AV200 pair (part number: ALAV200P) One AdderLink AV200T transmitter and one AdderLink AV200R receiver. • AdderLink AV200 transmitter (part number: ALAV200T) Single AdderLink AV200T transmitter. • AdderLink AV200 receiver (part number: ALAV200R) Single AdderLink AV200R receiver. • AdderLink AV201 receiver (part...
Page 30
29 Emissions and Immunity A Category 5 (or better) twisted pair cable must be used to connect th\ e modules in order to maintain compliance with radio frequency energy emis\ sion regulations and ensure a suitably high level of immunity to electromagne\ tic disturbances. All other interface cables used with this equipment must be shielded in \ order to maintain compliance with radio frequency energy emission regulations \ and ensure a...