ADDER CCSXB Quick Start
Have a look at the manual ADDER CCSXB Quick Start online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 78 ADDER manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
www.adde r.co m CCS-X B CCS-XB Quick Start Safety information • For use in dry, oil free indoor environments only. • Not suitable for use in hazardous or explosive environments or next to highly flammable materials. • Ensure that all twisted pair interconnect cables are installed in compliance with all applicable wiring regulations. • Do not connect the CATx cable(s) (RJ45 style connector(s)) to any other equipment, particularly network or telecommunications equipment. • Where possible, avoid laying the twisted pair link cable(s) alongside power cables. • Do not attempt to service the modules yourself. Warranty Adder Technology Ltd warrants that this product shall be free from defects in workmanship and materials for a period of two years from the date of original purchase. If the product should fail to operate correctly in normal use during the warranty period, Adder will replace or repair it free of charge. No liability can be accepted for damage due to misuse or circumstances outside Adder’s control. Also Adder will not be responsible for any loss, damage or injury arising directly or indirectly from the use of this product. Adder’s total liability under the terms of this warranty shall in all circumstances be limited to the replacement value of this product. If any difficulty is experienced in the installation or use of this product that you are unable to resolve, please contact your supplier. Self adhesive rubber feet CCS-XB controller Four LED monitor indicatorsAdder P/N: CCS-LED (Also available separately when more than four are required) CATx link cableAdder P/N: VSC46 What’s in the box Connection overview inside Full user guide available at www.adder.com© 2014 Adder Technology Limited • All trademarks are acknowledged. Part No. MAN-CCS-XB-QS • Release 1.1f (to be r2.0a on release) Web: www.adder.com Contact: www.adder.com/contact-details Support: forum.adder.com The CCS-XB module works together with either the Adder CCS4-USB or CCS-PRO4 switches to provide LED indicators for each of your video display screens. As the switch activates a screen, the CCS-XB module activates the corresponding indicator (which can be attached to the screen) to provide extra clarity for the operator. Checking the firmware version (CCS4-USB switches only) When using the CCS-XB module with a CCS4-USB switch, it is important that the switch has firmware version 2.0 (or greater) installed. If in doubt you can check the firmware version of your CCS4-USB switch as follows: 1 With your CCS4-USB switch powered on and with a USB keyboard attached, press and hold the COMPUTER button for roughly six seconds until the display shows C. 2 On the connected keyboard, press F followed by 1 and then press Enter. The digits of the firmware version will be shown in sequence with a short pause between each. For instance,1 > 0 > 2 means that the firmware version is 1.02 and requires an upgrade. 3 Press E and then press Enter to return the CCS4-USB to normal operation. If your CCS4-USB switch does require a firmware upgrade, please refer to the Performing upgrades section of the CCS4-USB user guide.
C Connection overview Steps to a successful installation 1 Use the supplied VSC46 CATx link cable (A) to connect the CCS-XB unit to the OPTIONS port of your CCS4-USB or CCS-PRO4 switch. 2 The next step depends on your switch type: • CCS-PRO4 - Use a standard patch cable (B) to connect the network port of your CCS-PRO4 to the network port of your computer (either directly or via a network switch - further information available in the CCS-PRO4 user guide), or • CCS4-USB - Use the VSC40 flash upgrade cable (C) (supplied with your switch) to connect the CCS-XB module to the serial port of your computer. 3 Connect the supplied LED monitor indicators (D) to the first four LED output ports on the CCS-XB module. 4 If your switch is not already powered on, apply power to it now. CCS4-USB switches need to be re-powered whenever a CCS-XB unit is re-attached; this prompts them to locate the CCS-XB unit. CCS-PRO4 switches can sense a newly attached CCS-XB unit without the need for re-powering. 5 Download and run the Free-Flow configuration application from the Adder website (www.adder.com) and follow the instructions given in the latest version of your CCS4-USB or CCS-PRO4 user guide (also available from the Adder website). The section ‘Configuring LED monitor indicators’ will show you how to assign an indicator to each display. Note: Once the LED monitor indicators have been programmed, you can remo\ ve the VSC40 flash cable or network patch cable connections as these are not required for operation. You will need to reconnect them, however\ , if you alter the LED assignments. OPTIONS port (CCS4-USB and CCS-PRO4 switches) Connect to a vacant serial port on your computer (CCS4-USB switches only) LED monitor indicators (one per video display) CATx link cable Adder P/N: VSC46 (Included in CCS-XB kit) Flash upgrade cable Adder P/N: VSC40 (Included in CCS4-USB kit) A D B Network port (CCS-PRO4 switches only) To a network switch or your computer’s network port