Adam Equipment SHS Crane Scales SHSSHSaREVB User Manual
Have a look at the manual Adam Equipment SHS Crane Scales SHSSHSaREVB User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

© Adam Equipment Company 2012 Adam Eq\bipme\ft SHS/SHSa SER\bES (P.N. 7.00.6.6.0202, Revisio\f B November 2012) Software versio\f S1.1/SA1.1

1 © Adam Equipment Company 2012 1.0 CONTENTS 1.0 CONTENTS ........................................... ................................................1 2.1 FEATURES ........................................................................................2 2.2 TECHNICAL SPECIFICATIONS........................... ..............................3 2.3 SAFETY NOTICE ...............................................................................4 2.4 KEY AND PANEL DESCRIPTION .......................... ............................5 2.5 DISPLAY INDICATIONS WITH LED...................................................6 3.0 OPERATION .........................................................................................6 3.1 SAFETY INSTRUCTIONS ................................ ..................................6 3.2 BATTERY OPERATION .....................................................................7 3.3 BASIC OPERATIONS ........................................................................8 3.4 REMOTE CONTROL UNIT ................................ ................................9 3.5 USER PARAMETERS ........................................................................9 4.0 CALIBRATION..................................................................................10 5.0 PARTS LIST ........................................................................................11 WARRANTY INFORMATION ........................................ ..............................13

2 © Adam Equipment Company 2012 2.0 INTRODUCTION 2.1 FEATURES The SHS/SHSa Series are a range of heavy-duty lower capacity crane scales The main features include: · Easy Operation & Rugged construction · 15mm bright red LED display enabling a good viewing angle. · 360 degree rotary safety hook and support ring desi gn · Overload safety up to 150% of model capacity · Selectable weighing units include kg, Lbs and Newto ns (Newtons not available for “a” models) · Standard and Peak Hold feature · Internal lithium battery fitted as standard · Alternative power from AA or NiMH batteries · Auto power off after 30 minutes of non use · 8.4Vdc 800ma battery charger · Strong ABS plastic housing · Infrared remote control

3 © Adam Equipment Company 2012 2.2 TECHNICAL SPECIFICATIONS Model No Capacity Division Model No Capacity Divisi on SHS 50 50kg 0.01kg SHS 100a 100lb/50kg 0.02lb/0.01kg SHS 150 150kg 0.02kg SHS 300a 300lb/150kg 0.05lb/0.02kg SHS 300 300kg 0.05kg SHS 600a 600lb/300kg 0.1lb/0.05kg

4 © Adam Equipment Company 2012 2.3 SAFETY NOTICE The limit stated below is the Ultimate Overload Lim its of the scales. Adam Equipment Co. Ltd. Its directors, owners and a ffiliated companies and organisations cannot be held liable for any resulti ng damage or injury sustained as a result of the machines being used in excess of thei r stated capacities or ultimate overload limits. Model No. SHS 50/SHS 100a SHS 150/SHS 300a SHS 300/ SHS 600a Max capacity 50kg/100lb 150kg/300lb 300kg/600lb Overload capacity 100kg/200lb 300kg/600lb 450kg/900lb NOTICE: Do not use the scales if any parts are bent or loos e or show signs of damage or wear. Refer to the user manual.

5 © Adam Equipment Company 2012 2.4 KEY AND PANEL DESCRIPTION [ON/OFF] The power switch is located on the rear housing. Us e this key to turn the scale ON and OFF. [Zero] Press the [Zero] key to return the reading to zero. [Unit] Press the [Unit] key to change the weighing unit being displayed between Kg, Lbs and Newtons (Newtons not available for “a” models) [Hold] Use this key to activate standard Hold. When pressed the Hold LED will light at the top left side of the display and the reading on the display will lock and flash. Press the [Hold] key again to cancel the [Hold] function. *When Peak hold is selected from the parameter sect ion the press of the Hold key will activate Peak Hold. The Hold LED will flash and the display will also flash and lock show ing the maximum weight registered of a single weighing process. Press the [Hold] key again to cancel the [Hold] function.

6 © Adam Equipment Company 2012 2.5 DISPLAY INDICATIONS WITH LED Kg lb N Weighing unit Indicator Low battery Indicator Hold Hold Indicator Stab Stable Indicator 3.0 OPERATION 3.1 SAFETY INSTRUCTIONS Read this manual carefully before you operate the S HS Crane Scale. · Unpack the Crane Scale carefully from the packaging . · Attach it to your hoist or equivalent existing equi pment securely at the ground level to the support ring in the upright pos ition. Make sure that the equipment to which the scale is attached is in proper condition. The operator should be trained for its safe operation. · Carry out regular visual inspection for any damage or wear and tear on parts. The split pins in particular at the hook and eyebolts, as well as the inner wall of the hook and all joints should be che cked regularly. If any damage or wear has taken place, stop using the scal e and replace the parts. · Do all inspection and maintenance work when the sca le is not in use. · Do not expose the scale to extreme temperatures. Th e operating temperature range is 0° C to 40° C. · Secure the sample to be weighed in the hook of the scale. Ensure that the sprung Safety Lever returns to its resting posi tion which prevents the sample from slipping out of the hook. · Do not exceed the maximum capacity of the Scale . · Clean and protect your scale after use.

7 © Adam Equipment Company 2012 Overload Warning Please do not add any item that exceeds the maximum capacity of the scale. When the display shows ”- - - - - ” remove the item to avoid damage to the load cell and scale. 3.2 BATTERY OPERATION · The lithium battery will operate continuously for 2 0 hours before requiring recharging. The scale will alert you that the battery is low on charge when the Indicator LED above the battery sym bol lights up. · To charge the battery, unclip the battery cover on the rear of the scale and insert the connector into the socket as marked. Plug the charger into the mains power supply and wait until the LED on the charger shows green. The battery is now fully charged. · Charging time for a completely discharged battery i s approximately 16 hours. A full battery pack is recommended to keep t he scale continuously operational. · Only use the charger as supplied with the unit. · The switch inside the battery cover must be in posi tion A to make use of the lithium battery. · If using AA or NiMH batteries the switch must be i n position B · The scale will automatically power down after 30 mi nutes of non use to further protect the battery. · To replace the lithium battery pack please contact your dealer

8 © Adam Equipment Company 2012 3.3 BASIC OPERATIONS Power on and off Press the [ON/OFF] button to turn the scale on or off. The display on the scale will show the model capacity then countdown from 9 to 0 before displaying zero weight. Zero the scale Press the [Zero] key so that the display shows zero. Change the weighing Unit Press the [Unit] key to change the weighing unit Standard Hold (setting 1) When the reading may not be perfectly stable or you cannot view a reading easily you can press the [Hold] key to lock it. The reading will be locked and also flash at the point you press the [Hold] button enabling you to view it when you can. The Hold LED will also light up and once you h ave noted the reading a press of the [Hold] key will return the scale to the normal weighing mode. Peak Hold (setting 0) Peak Hold is the highest weight reading registered by the scale when a weighing takes place. Press the [Hold] key when the display is at zero and the Hold LED will flash which denotes Peak Hold has been activat ed. When weight/force is applied to the scale the display will also flash an d lock the highest recorded weight of that weighing process. This value and the Hold LED will remain flashing on the display until the [Hold] key is pressed again at which point the scale will return to normal weighing mode displaying the curre nt weight on the scale. Press [Hold] again to perform another Peak Hold weighing at any time.

9 © Adam Equipment Company 2012 3.4 REMOTE CONTROL UNIT The remote control works via infra red and can be u sed to operate the SHS from long distances. It operates using 2 x AAA batteries and these can be exchanged by unclipping a cover on the rear of the remote contro l unit. 3.5 USER PARAMETERS Four USER settable parameters are available on the SHS, to access these power up the scale and whilst the display is counting dow n press and then release the [Unit] button. The display will show Bee 0. Press the [Hold] button to change the setting, and the [Zero] button to move to the next parameter. Parameter setting table. FUNCTION DESCRIPTION DEFAULT BEE Sets buzzer 0: Disable 1: Enable 1 HOD Sets the Hold function 0: Peak 1: Standard 1 CHT Sets weighing unit on power up 0: kg 1: Lb’s 2: Newtons(Newtons not available for “a” models) 0 YES Sets save: 0: not saved 1: save new settings 0