Adam Equipment PMB Moisture Analyser PMBIT User Manual
Here you can view all the pages of manual Adam Equipment PMB Moisture Analyser PMBIT User Manual. The Adam Equipment manuals for Moisture Analyzer are available online for free. You can easily download all the documents as PDF.
Page 1
© 2013 Adam Equipment Adam Equipment PMB Moisture Analyzer (EN) PMB Analizzatore d’umidita’ (IT) (P.N. 3076610544, RevisionC3, July 2013) Adam Equipment strives to be more environmentally focused and uses recycled materials and environmentally friendly packaging where possible. As part of this initiative we have developed a short form manual that uses less paper and ink to describe the main functions of your new Adam moisture analyzer. A complete version is available...
Page 3
EN © 2013 Adam Equipment 1 3076610544, RevisionC3, July 2013 SAFETY This Moisture Analyzer complies with the European Council Directives and international standards for electromagnetic compatibility, and safety requirements. · Improper use or handling can result in damage or injury. · To prevent damage to the equipment, read these operating instructions thoroughly. Keep these instructions in a safe place. · The Moisture Analyzer is used for determination of the moisture in samples. Do...
Page 4
EN © 2013 Adam Equipment 2 3076610544, RevisionC3, July 2013 1.0 CONTENTS SAFETY .................................................................................................................................................. 1 HOT SURFACES ................................................................................................................................ 1 MATERIALS...
Page 5
EN © 2013 Adam Equipment 3 3076610544, RevisionC3, July 2013 2.0 OPERATION 2.1 TURNING ON THE ANALYZER FOR THE FIRST TIME Set your analyzer in a well ventilate room and away from any flammable substances. Ensure that you are using the correct voltage for the analyzer. The voltage is shown on the back of the unit. The master on /off switch is located on the back. To turn on the unit press the on / off switch at the rear of the analyzer, the display will show the serial number and software...
Page 6
EN © 2013 Adam Equipment 4 3076610544, RevisionC3, July 2013 S\fNGLE ºC 123 RAMP ºC RAMP T\fME 123 06:00 STEP 1 TEMP ºC \f 100 03:00 STEP 2 TEMP ºC STEP 2 T\fME 120 03:00 STEP 3 TEMP ºC \f 140 03:00 \fNTERVAL SEC 10 Display shows rESULt Options are: Moisture, Solid, ATRO Moist, ATRO Solid To set a test press the [Test] key Use arrow keys, [Dspl] and [Test] , to change...
Page 7
EN © 2013 Adam Equipment 5 3076610544, RevisionC3, July 2013 The user can print the current configuration by pressing the [Print] key during the process providing the second function for that key is not needed. ST\bP T\fME Min 30 STAB RANGE stAB time 02 sec15 stop time stop RANGE stop time min 30 02 sec15 Display, shows St\bP Options are: Time, Stab or Time / Stab Option T\fME Will...
Page 8
EN © 2013 Adam Equipment 6 3076610544, RevisionC3, July 2013 2.3 RUNNING A TEST Once the test procedure has been set then a test can be run using the current settings. A test can also be recalled from memory See USING THE INTERNAL MEMORY. Place an empty sample pan on the analyzer. Press [Tare] to zero the weight. Remove and fill the sample pan with the sample. Place the filled pan on the analyzer. Lower the lid of the weighing chamber, a. If automatic start has been...
Page 9
EN © 2013 Adam Equipment 7 3076610544, RevisionC3, July 2013 When the test has stopped the beeper will sound 3 short beeps (if enabled) and the display will show the end result: This display shows the test was automatically stopped as stability was reached in 12:44 minutes. If it had stopped at the end of the time period it would have TSTOP on the top line and if manually stopped it would have MSTOP. At this time the final results are displayed. These results will include elapsed...
Page 10
EN © 2013 Adam Equipment 8 3076610544, RevisionC3, July 2013 3.0 USING THE INTERNAL MEMORY SETTING 3.1 STORING TEST SETTINGS It will be possible to store up to 49 test procedures/settings. There is also a factory default that is permanently stored as PST 00. To Store the current settings press the [PST] key. The display will give the user the option to store, recall or delete a Preset Test. The display will show PST ST\bRE or PST RECALL or PST DELETE. Use the up/down arrow keys,...