Adam Equipment MDW Physician Scales MDW300LREVA2 User Manual
Have a look at the manual Adam Equipment MDW Physician Scales MDW300LREVA2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Page 1 Adam Equipment MDW – 300L HEALTH AND FITNESS SCALE with BMI ADAM EQUIPMENT CO. LTD. p.n. 700660159 Rev. A2, Apr 2014
Page 2 CONTENTS 1.0 INTRODUCTION ...................................... ..................................................... 3 2.0 TECHNICAL SPECIFICATIONS .......................... ......................................... 3 3.0 DISPLAY AND KEY DESCRIPTIONS ...................... .................................... 4 4.0 SETTING UP THE SCALE ............................................................................ 5 5.0 FUNCTION ................................................................................................... 7 5.1 WEIGHING .......................................... ...................................................... 7 5.2 MEASURING HEIGHT .................................. ............................................ 8 5.3 MEASURING BODY MASS INDEX (BMI) ................... .............................. 8 6.0 CALIBRATION .............................................................................................. 9 7.0 USER PARAMETERS ................................... ............................................. 10 8.0 RS232 COMMUNICATIONS .............................. ......................................... 11 9.0 ERROR MESSAGES .................................................................................. 15 10.0 WARNING ................................................................................................... 15 WARRANTY INFORMATION .............................. .................................................. 17
Page 3 1.0 INTRODUCTION · The MDW 300L scale is a Digital Health and Fitness Scale with Body Mass Index (BMI) readout. · It is an accurate electronic device with advanced design and stable performance. · It is designed to measure both the weight and the height of a person and compute the BMI index. 2.0 TECHNICAL SPECIFICATIONS Maximum capacity 300 kg / 660lb Minimum capacity 2 kg / 4lb Scale division 0.05kg / 0.1lb Height range 60 cm-212 cm / 24”-83” Division of measurement (height used in BMI calculation) entry via keypad 1cm / 0.5” Division of measurement (height measurement) 0.1cm / ⅛” Display LED display Size of platform 375 X 275 mm 14.75” X 10.8” Overall dimension, height pillar in lowest position 570 X 275 X 1310 mm 22.4” X 10.8” X 51.5” Net weight 13 kg / 29 lb. Environment for Use Temperature: 5ºC-40ºC; Humidity:
Page 4 3.0 DISPLAY AND KEY DESCRIPTIONS KEYS FUNCTIONS [On/Off / Zero] To turn the scale on or off. To zero the scale if the display drifts from zero. [Tare] ¿ ¿¿ ¿ To tare the scale, if necessary. Accept settings as required [Units / BMI] To toggle the weighing unit between Kg and Lb. and to select the BMI function. Move active digit to the right when req uired. [Print / Hold] To lock the reading even if the person to be weighe d is moving and also to print the weight via the RS232 interface. I ncrease value or settings when required. DISPLAY DESCRIPTIONS Kg Indicates when the scale is weighing in Kilograms. Lb Indicates when the scale is weighing in Pounds. Hold Indicates when the scale has held the weight readin g shown on the display. It will flash until it locks into the stab le reading when it will then remain on for a preset time when it has held the di splayed reading. BMI Indicates when the scale is displaying the Body Mas s Index value. CH The charge light will be on when the battery is recharging. AC This indicates when the scale is being used with th e AC adapter. ZERO This indicator will be displayed in the left corner when the scale reaches zero. NET The Net weight is displayed, Tare weight is at zero .
Page 5 4.0 SETTING UP THE SCALE · Take the scale out of the box. 1. Locate the 4 screws (2) 2. Place the cable (4) through the pillar (3). 3. Insert the 4 screws (2) through the holes on the pillar bracket and secure the bracket to the indicator (1), 4. Make sure the screws are securely tightened. 5. Place the cable (4) into the tube support (6) on the scale base. 6. Insert the pillar (3) into the tube support (6). 7. Rotate the pillar to position the indicator (1) in the direction desired, and then secure using the 2 screws (5) into the fixing tube (6). 8. Locate the load cell cable (13) ready for connection
Page 6 9. Place the indicator cable (4) and the load cell cable (13) together near the hole on the base (16). 10. Plug the two connectors (15) together. 11. Position the connector inside the base (16). 12. The cables should be fixed to the base using the clip provided (14). 13. Locate the fixing bolt and washer (10) used to secure the height rod to the scale base (11) 14. Locate the height rod (7) onto the fixing points (9) of the upper and lower brackets (8) & (12). 15. Secure the bolt and washer to the bracket on the base (10) 16. Tighten the bolt on the upper bracket (9).
Page 7 5.0 FUNCTION 5.1 WEIGHING · Place the Scale on an even floor and press the [On/Off] key. · The instrument performs a self-test after which it is ready for operation. · Press the [On/Off] key and the machine switches off. · The person to be weighed can step on to the platfo rm once the scale shows 0.0 on the display. The weight will be display in K g. or lb. depending on the units chosen by the user. · If the weighing value is to be tared press the tar e key to remove the weight value from the display. · Press the [Units] key for changing the weighing unit to kg or lb. Th e LED will indicate the chosen weighing unit. · Overload display : When “ FULL” appears on the display, it shows that the load on the platform is over the maximum capacity. Under these circumstances, it is necessary to reduce the load otherwise the senso r or the platform will be damaged. · Hold Function: To lock the weighing result, press the [Print/Hold] key. The LED will flash until a stable reading has been obta ined and then it will light up constantly. The weight will be displayed until the hold time has expired (see Sec 7.0) or to manually release the function, press the [Print/Hold] key again. · Print Function: To send the weighing result to a printer or comput er press the [Print/Hold] key when the [Print/Hold] key has been set up in the parameter section to work as print function.
Page 8 5.2 MEASURING HEIGHT · To measure someones height, it is necessary to ext ract the measuring rod and place the height arm on top of the head of the pers on being measured. · For shorter heights the height arm can be released by pressing the red button on the top of the height rod, and then moving the h eight arm to the lower section of the height pillar. · The height is read on the bar at the top of the su pport. The height can be read in either centimetres or inches, 5.3 MEASURING BODY MASS INDEX (BMI) · Once the height has been determined it is possible to enter the height reading into the display ready for the scale to compute the BMI. · Press and hold the [Unit/BMI] key to enter the BMI mode. The display will show the last height value used, “ Cm123” or “In123” depending on which weighing unit you are currently using. · The height entry unit (Cm or In) will be flashing to show you which unit you are currently in, use the Up arrow key to change the he ight entry unit between Cm to In as required · Enter your height using the arrow keys, the [Print/Hold] / key will increment the flashing digit, the right arrow, the [Unit/BMI] / key, will move the flashing digit to the adjacent digit. · Press the [Tare]/¿ ¿¿ ¿ key to confirm the value. · The display will now show the BMI based on the cur rent weight on the scale and the height entered. · Press the [Unit/BMI] key to exit the BMI mode and return to normal weig hing. · The Hold function will work as described above whi lst in the BMI mode.
Page 9 6.0 CALIBRATION Before calibrating the scale, you should ensure that you have a suitable known weight for calibration. 1. When in normal weighing mode with the scale at zero press and hold down [TARE] and [ON / OFF] keys to enter the calibration mode. 2. If the calibration switch is in the off position on the main PCB inside the scale, the indicator will show “ CAL.OFF” and then exit this mode. If the indicator shows “ CAL-? ”, the scale is ready for calibration. 3. When the indicator shows “C AL-?”, press the [TARE] key to confirm and go to next step, or press the [ON / OFF] key to exit the calibration mode. 4. When ‘ 0.0’ is displayed the scale will begin to calibrate th e scale’s zero-point. Ensure that there is no load or weight on the scale’s plat form. Press the [TARE] key to confirm, or press the [ON / OFF] key to exit this mode. 5. A few seconds after the [TARE] key has been pressed in step 4 the scale will show “300.0” and the kg LED, or “600.0” and the lb LED d epending on which unit you chosen, this is the default calibration weight from the fac tory. Press the [UNIT] key to select the calibration weight unit that you want to calibrate in. Press the [ON / OFF] key to exit the calibration mode at this point or press the [Print/Hold] key to choose a different calibration weight value (50kg, 100kg, 150kg, 200kg , 250kg, 300kg or 100lb, 200lb, 300lb, 400lb, 500lb, 600lb); Then put on the weight that you selected and press the [TARE] key to confirm the chosen standard weight that was selected earlier. The displayed data will flash on the display and if the scale accepts the calibration data it will calculate and store the information into the EEPROM . If an error has occurred, the scale will display “CAL. Er” and return back to step 4 fo r re-calibration. If the loaded weight is not within the range of 95% to 105% of the weight v alue you selected, the scale will not calibrate but display “CAL. Er” and return back to step 4 for re-calibration. ) 6. Check the calibration by putting the weight that yo u calibrated at back on the scale, if it is off repeat the calibration process again.
Page 10 7.0 USER PARAMETERS This indicator has 4 parameter settings that can be selected. 1. When the scale is in normal weighing mode, press an d hold down the [ON / OFF] key and the [UNIT] key for 3 seconds until ‘ Setup’ is shown on the display. 2. When in the SETUP mode, press the [Print/Hold] key to change the flashing digits, and [TARE] key to confirm the flashing digits and move to the next parameter setting. Press the [ON / OFF] key to exit the set up mode. 3. Parameters setting summary: Parameter x/xy Factory Set Setting A.o.t. 00-15 05 Auto-off time: No auto-off = 00. 01-15 minutes auto-off time. P.H. 0,1,2 1 0 = Only Print Function 1 = Only Hold Function 2 = both HOLD and PRINT function (pressed down less 3s,this key works as Print function; pressed down more than 3s,this key works as HOLD function) H.t 0-4 0 Hold time: 0 = no time limit. 1 = 10 seconds 2 = 30 seconds 3 = 60 seconds 4 = 120 seconds S.F. 0-3 0 0 = No RS232 Function. 1 = Continuously outputs display data. 2 = Output display data when PRINT pressed 3 = Bi-directional communication (the scale receives and executes commands from the HOST device)