    Have a look at the manual Adam Equipment MDW Physician Scales MDW250LREVE User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							© Adam Equipment Company 2011 
    Adam Equipment 
    MDW – 250L 
    PHYSICIAN SCALE with BMI 
    ADAM EQUIPMENT CO. LTD. 
    p.n. 700660146  Rev. E, February 2011    
    						
    							© Adam Equipment Company 2011              Page 1    
    						
    							© Adam Equipment Company 2011              Page 2   
       
       
    CONTENTS    
    1.0  INTRODUCTION ....................................... ...................................................4 
    2.0   TECHNICAL SPECIFICATIONS ........................... ....................................... 4 
    3.0   DISPLAY AND KEY DESCRIPTIONS ....................... ................................... 5 
    4.0   SETTING UP THE SCALE ............................... ............................................ 6 
    5.0   FUNCTION ........................................... ........................................................ 8 
    5.1   WEIGHING ........................................... .................................................... 8 
    5.2   MEASURING HEIGHT................................... ........................................... 9 
    5.3   MEASURING BODY MASS INDEX (BMI) .................... ............................ 9 
    6.0   CALIBRATION........................................ .................................................... 10 
    7.0   USER PARAMETERS .................................... ............................................ 11 
    8.0   RS232 COMMUNICATIONS ............................... ....................................... 12 
    9.0   ERROR MESSAGES ..................................... ............................................ 16 
    10.0  WARNING ............................................ ...................................................... 16 
      
    						
    							© Adam Equipment Company 2011              Page 3    
    						
    							© Adam Equipment Company 2011              Page 4   
     
    1.0  INTRODUCTION 
       
    ·   The MDW 250L scale is a Digital Physician Scale wi th Body Mass 
    Index (BMI) readout. 
      
    ·  It is an accurate electronic device with advanced  design and stable 
    performance. 
     
    ·  It is designed to measure both the weight and the  height of a person 
    and compute the BMI index.  
         
    2.0  TECHNICAL SPECIFICATIONS 
         
    Maximum capacity  250 kg / 550lb 
    Minimum capacity  2 kg / 4lb 
    Scale division  0.1Kg / 0.2lb 
    Height range  60 cm-212 cm / 24”-83” 
    Division of measurement  0.1 cm / 1/8” 
    Display  LED  display 
    Size of platform  375 X 275 mm 
    14.75” X 10.8” 
    Overall dimension, height  
    pillar in lowest position 570 X 275 X 1310 mm 
    22.4” X 10.8” X 51.5” 
    Net weight  13 kg / 29 lb. 
    Environment for Use  Temperature: 5ºC-40ºC;  Humidity: 
    						
    							© Adam Equipment Company 2011              Page 5   
    3.0  DISPLAY AND KEY DESCRIPTIONS 
     
     
      
    KEYS  FUNCTIONS 
    [On/Off /  
    Zero]  To turn the scale on or off. 
    To zero the scale if the display drifts from zero. 
    [Tare] 
    ¿
    ¿¿
    ¿
      To tare the scale, if necessary. Accept settings as
     required 
    [Units /  
    BMI] 
    
    
      To toggle the weighing unit between Kg and Lb. and 
    to select the BMI 
    function.   Move active digit to the right when req uired. 
    [Print /  
    Hold] 
    
    
      To lock the reading even if the person to be weighe
    d is moving and 
    also to print the weight details if RS232 interface  is installed. Increase 
    value or settings when required. 
      
    DISPLAY  DESCRIPTIONS 
    Kg  Indicates when the scale is weighing in Kilograms. 
    Lb Indicates when the scale is weighing in Pounds. 
    Hold Indicates  when  the  scale  has  held  the  weight  readin g  shown  on  the 
    display.  It  will  flash  until  it  locks  into  the  stab le  reading  when  it  will 
    then  remain  on  for  a  preset  time  when  it  has  held  t he  displayed 
    reading. 
    BMI  Indicates when the scale is displaying the Body Mas s Index value. 
    CH The charge light will be on when the battery is rec harging. 
    AC   This indicates when the scale is being used with th
    e AC adapter. 
    ZERO This  indicator  will  be  displayed  in  the  left  corner   when  the  scale 
    reaches zero. 
    NET  The Net weight is displayed, Tare weight is at zero .   
    						
    							© Adam Equipment Company 2011              Page 6   
     
    4.0  SETTING UP THE SCALE 
       
    ·  Take the Physician scale out of the box.  
     
     
       
     
      1. Locate the 4 screws (2)    
    2. Place the cable (4) through the pillar 
    (3).  
    3. Insert the 4 screws (2) through the 
    holes on the pillar bracket and secure 
    the bracket to the indicator (1),   
    4. Make sure the screws are securely 
    tightened. 
         
    5. Place the cable (4) into the tube 
    support (6) on the scale base.  
    6. Insert the pillar (3) into the tube 
    support (6).  
    7. Rotate the pillar to position the 
    indicator (1) in the direction desired, 
    and then secure using the 2 screws 
    (5) into the fixing tube (6).     
    						
    							© Adam Equipment Company 2011              Page 7   
     
     
       
     
          8. Locate the load cell cable (13) ready for 
    connection  
    9. Place the indicator cable (4) and the 
    load cell cable (13) together near the hole 
    on the base (16).  
    10. Plug the two connectors (15) together.   
    11. Position the connector inside the base 
    (16).  
    12. The cables should be fixed to the base 
    using the clip provided (14).  
    13. Locate the fixing bolt and washer 
    (10) used to secure the height rod to 
    the scale base (11)  
    14. Locate the height rod (7) onto the 
    fixing points (9) of the upper and lower 
    brackets (8) & (12).  
    15. Secure the bolt and washer to the 
    bracket on the base (10)    
    16. Tighten the bolt on the upper 
    bracket (9).     
    						
    							© Adam Equipment Company 2011              Page 8   
    5.0  FUNCTION 
     
    5.1  WEIGHING 
     ·  Place the Physician Scale on an even floor and pre ss the [On/Off]  key.  
     
    ·  The instrument performs a self-test after which it  is ready for operation.  
     
    ·  Press the  [On/Off] key and the machine switches off.  
     
    ·  The  person  to  be  weighed  can  step  on  to  the  platfo rm  once  the  scale 
    shows  0.0  on  the  display.  The  weight  will  be  displa y  in  Kg.  or  lb. 
    depending on the units chosen by the user.  
     
    ·  If  the  weighing  value  is  to  be  tared  press  the  tar e  key  to  remove  the 
    weight value from the display. 
     
    ·  Press  the  [Units]  key  for  changing  the  weighing  unit  to  kg  or  lb.  Th e 
    LED will indicate the chosen weighing unit. 
     
    ·  Overload  display :  When  “
    FULL”  appears  on  the  display,  it  shows  that 
    the  load  on  the  platform  is  over  the  maximum  capaci ty.  Under  these 
    circumstances,  it  is  necessary  to  reduce  the  load  o therwise  the  sensor 
    or the platform will be damaged. 
       
    ·  Hold  Function:   To  lock  the  weighing  result,  press  the  [Print/Hold] 
    key.  The  LED  will  flash  until  a  stable  reading  has  been  obtained  and 
    then it will light up constantly. The weight will b e displayed until the hold 
    time  has  expired  (see  Sec  7.0)  or  to  manually  relea se  the  function, 
    press the  [Print/Hold]  key again. 
      
    ·  Print  Function:   To  send  the  weighing  result  to  a  printer  or  comput er 
    press  the  [Print/Hold]  key  when  the  [Print/Hold] key  has  been  set  up 
    in the parameter section to work as print function.  
    (Print function is only applied for scale with RS23 2 interface) 
                
    						
    							© Adam Equipment Company 2011              Page 9   
    5.2  MEASURING HEIGHT  
     ·  To measure some ones height, it is necessary to ex tract the measuring 
    rod  and  place  the  height  arm  on  top  of  the  head  of  the  person  being 
    measured.   
     
    ·  For shorter heights the height arm can be released  by pressing the red 
    button  on  the  top  of  the  height  rod,  and  then  movin g  the  height  arm  to 
    the lower section of the height pillar.  
     
    ·  The height is read on the bar at the top of the su pport.   The height can 
    be  read  in  either  centimetres  or  inches,  however  th e  BMI  function  will 
    only accept the centimetre values.   
     
    5.3  MEASURING BODY MASS INDEX (BMI)   
     
    ·  Once  the  height  has  been  determined  it  is  possible   to  enter  the  height 
    reading into the display ready for the scale to com pute the BMI.  
     
    ·  Press and hold the  [Unit/BMI] key to enter the BMI mode.  The display 
    will  show  the  last  height  value  used,  “
    Cm123”  or  “In123”  depending  on 
    which weighing unit you are currently using. 
      ·   The height entry unit (Cm or In) will be flashing  to show you  which unit 
    you  are  currently  in,  use  the  Up  arrow  key  to  chang e  the  height  entry 
    unit between Cm to In as required 
     
    ·  Enter  your  height  using  the  arrow  keys,  the  [Print/Hold]  /
     key  will 
    increment the flashing digit, the right arrow, the  [Unit/BMI] /
     key, will 
    move the flashing digit to the adjacent digit. 
     
    ·  Press the  [Tare]/¿
    ¿¿
    ¿
     key to confirm the value. 
     
    ·  The  display  will  now  show  the  BMI  based  on  the  cur rent  weight  on  the 
    scale and the height entered. 
     
    ·  Press  the  [Unit/BMI]  key  to  exit  the  BMI  mode  and  return  to  normal 
    weighing.  
     
    ·  The Hold function will work as described above whi lst in the BMI mode. 
      
    						