    Have a look at the manual Adam Equipment MCW Chair Weighing Scale MCW300L User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							© A dam Equipment  Company 2012              P age 9   
    10. Feed t he cable f rom t he Indicat or t hrough t he pillar  
    11.  Connect  t he p illar t o t he Indicat or using t he 4  x M 4  x 
    8   screw s provided  
     
     
     
     
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 10   
    12. Feed t he cable t hrough t he t ube on t he base  
    13.  Connect  t he pillar t o t he base and t ight en t he allen      
    screw  t o secure in t he correct  view ing posit ion  
     
     
     
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 11   
    1 4 .  Connect  t he Indicat or cable t o t he load cell cable    
    connect or ensuring t o t hread t he cable t hrough t he 
    bracket  under t he base  
      1 5 .  Secure t he cables using t he P clip and M 4  x 8  screw       
            provided  
     
     
     
     
     
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 12   
     1 6 .  Connect  t he handle using t he 4  x M 5  x 3 0  screw s    
    provided  
     
     
     
     
     
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 13   
     17.  Connect  t he t w o arm rest s using t he 4  x M 6  
    w ashers and 4  x M 6  x 2 0  socket  head screw s 
    provided  
     
     
     
     
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 14   
    1 8 .  Place t he chair assembly ont o t he base and secure 
    using t he 4  x M 5  x 1 5  screw s provided  
     
     
     
     
     
     
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 15   
    1 9 .  Place t he f oot  rest  ont o t he assembly and se cure 
    using t he 4 x M5 x 15 screws provided      
     
     
     
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 16   
    5.0  FUNC TION 
     
    5.1 WEIGHING  
     
    •  Position  the Scale on an even floor  and press the  [On/Off] key .  
     
    • The instrument  performs a self -test after which it  is  ready for operation.   
     
    • Press the  [On/ Off]  key  and the mac hine switches off.   
     
    • The person to be weighed  can sit on to the chair  once the scale shows 
    0.0 on the display. The weight will be display in Kg. or lb. depending on 
    the units chosen by the user.   
     
    •  If the weighing value  is to be tared press the tare key to remove the 
    weight value from the display.  
     
    •  Press  the [Units ]  key  for changing the weighing unit to  kg or lb. The 
    LED will  indicate the chosen weighing unit.  
     
    • Overload display : W hen “
    FULL” appears on the  display, it shows that 
    the load on the chair  is over the maximum capacity . Under these 
    circumstances, it is necessary to reduce the load otherwise the sensor 
    or the chair  will be damaged.  
     
     
    • Hold Function:  To l ock  the weighing result , press the [ Print/Hold] 
    key. T he LED will flash until a stable reading has been obtained and 
    then it will light up constantly. The weight will be displayed until the hold 
    time has expired (see Sec 7.0) or t o  manually release the function, 
    press the [ Print/Hold ] key again.  
     
     
    • Print  Funct ion:  To send t he w eighing result  t o a print er or comput er 
    press t he [ Print/Hold] key when the [ Print/Hold] key has been set up 
    in the parameter section to work as print  function 
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 17   
    5.2 MEASURING BODY MASS INDEX (BMI)    
     
    • Once the height has been determined it  is possible to enter the height 
    reading into the display  ready for the scale to  compute  the BMI.   
     
    • Press and hold the [Unit/BMI]  key to enter the BMI mode.  The display 
    will  show the last height value used,   “Cm123 ” or “In123” depending on 
    which weighing unit you are currently using . 
     
    •  The height entry unit  (Cm or In) will be flashing to show you which unit 
    you are currently in, use the Up arrow key to change the height entry 
    unit between Cm to In as required  
     
    • Enter your height using the  arrow keys , the  [Print/Hold]  /  key  will 
    increment the flashing digit, the right arrow , the  [Unit/BMI]  /  key,  will 
    move the flashing digit to the adjacent digit.  
     
    •  Press the [Tare] /↵ key to confirm the value.  
     
    • The display will now show the BMI based on the current weight on the 
    scale and the height entered.  
     
    • Press the [Unit/BMI]  key to exit the BMI mode and return to normal 
    weighing.   
     
    • The Hold function will work as described above whil st in the BMI mode.  
     
    C  O  P Y  
    						
    							© A dam Equipment  Company 2012              P age 18   
     
    6.0 
    CALIBRA TION 
     
    Before calibrating the scale, you should ensure that you have a suitable known 
    weight for calibration.   
     
    1.  When in normal weighing mode with the scale at zero press and hold down 
    [TARE]  and [ON / OFF]  keys to enter the calibration mode.   
     
    2.  If the calibration switch is in the off  position on the main PCB inside the scale, the 
    indicator will show “ CAL.OFF ” and then exit this mode. If the indicator shows 
    “C AL -?”, the scale is ready for calibration. 
     
    3.  When the indicator shows “ CAL -?”, p ress  the [TARE]  key to confirm and go to 
    next step, or press the  [ON / OFF] key to exit the calibration mode.   
     
    4.  When ‘ 0.0’ is displa yed the scale will begin to calibrate the  scale’s zero -point . 
    Ensure that there is no load or weight on the  scale’s chair . Press  the  [TARE]  key 
    to confirm, or press  the  [ON / OFF] key  to exit this mode.   
     
    5.  A few seconds after the  [TARE] key has been pressed  in step 4 the scale will 
    show  “300.0” and the kg  LED , or “600.0” and the lb LED depending on which unit 
    you chosen,  this is the default calibration weight from the factory . Press the 
    [UNIT]  key to select the calibration weight unit that you want to calibrate in.  Press 
    the  [ON / OFF]  key to exit the calibration mode at this point or press  the 
    [ Print/Hold ] key to choose a different calibration weight  value (50kg, 100kg, 
    150kg, 200kg , 250kg , 300kg  or 100lb, 200lb, 300lb, 400lb, 500lb , 600lb); Then 
    put on the weight that you selected and press the  [TARE] key to confirm the 
    chosen  standard weight  that was selected earlier . The displayed data will flash 
    on the display and if the scale accepts the calibration data it will calculate and 
    store the information into t he EEPROM. If  an error  has occurred, the scale will 
    display “CAL. Er” and return back to step 4 for re- calibration. If the load ed weight 
    is not with in the  range of 9 5% to 105% of the weight value you  selected,  the 
    scale will not calibrate but  display  “CAL.  Er” and return back to step 4 for re-
    calibration. )  
     
    6.  Check the calibration by putting the weight that you calibrated at back on the 
    scale, if it is off repeat the calibration process again.  
     
    C  O  P Y  
    						