Home > Adam Equipment > Scale > Adam Equipment Coin Counting Scale CCSArevA1 User Manual

Adam Equipment Coin Counting Scale CCSArevA1 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Adam Equipment Coin Counting Scale CCSArevA1 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							9 | P a g e   © Adam Equipment Company 2009 
    2.6  BACKLIGHT OPERATION 
     The  LCD  display  has  a  backlight  that  operates  autom atically.  To 
    maximise  the  battery  life  it  may  be  necessary  to  tu rn  the  backlight 
    off. 
     
      Hold  the  [Print]  key  for  4  seconds  to  enter  the  backlight  control 
    mode. Use the  [MC / ] key to change the setting for the backlight to 
    OFF, ON (set to on for full time) or AUTO (set to o n only when there 
    is a weight on the scale). 
    2.7  TEMPORARY
     WEIGHT DISPLAY 
      Press  and  hold  the  [CE/Esc]  key  for  4  seconds  for  the  display  to 
    change the weight in the  Denomination window.   
     
      Pressing  any  key  except  the  [Tare]  and [CE/Esc]   keys  will  have  no 
    effect  to  the  operation.  Pressing  [Tare]  will  operate  as  a  Tare 
    function and  [CE/Esc] will return the scale to normal operation.   
    2.8  SETTING
     DATE AND TIME 
    The Real Time Clock (RTC) is used only for the RS-2 32 output.  The Date 
    and Time can be set as required.  The scale will ke ep the clock running even 
    when the power is off.    
    Setting up the clock    
      Press and hold the  [1c] key when power is first turned on, release the 
    key when the revision is displayed.  The initial di splays show the current 
    date and time set.   
     
    “  rtC        “  “ 11,14,06 ”  “16,41,35 ”  
      Press the  [CE] key to change the date and time.  The display will  show 
    the current time format, “ H-m-S”. 
     
      Enter the time using the numeric keys using a 24 h our clock format, 
    3:41PM is “ 154100”. 
       
      Press the  [Total/
    
    
    ] key to accept the time.  The display will show the  
    current date format.   
     
      Press the  [MC/
    
    
    ]  key to change the date format. Available formats 
    are:  
    						
    							10 | P a g e    © Adam Equipment Company 2009 
     
    “Y-m-d ”   year, month, day 
    “ m-d-Y ”   month, day, year 
    “ d-m-Y ”   day, month, year 
     
      Press the  [Total/
    
    
    ] key to accept the chosen format and then enter the  
    date in this format.   
     
      Press the  [Total/
    
    
    ] key to accept the date. 
      
    An error code will be shown if the time ( Err 1) or the date ( Err 2) is not the 
    permissible values.   For example, 34
    th day of a month is an invalid entry. 
          
    						
    							11 | P a g e    © Adam Equipment Company 2009 
     
    3.0  BASIC OPERATION 
    3.1  ZEROING THE DISPLAY 
     
     Press  the  [>ZZZ
    						
    							12 | P a g e    © Adam Equipment Company 2009 
     When  both  the  product  and  container  are  removed  the  Quantity  
    and  TOTAL  display will show bars “- - - - -“ as the weight i s below 
    zero. 
     
      If  a  different  container  is  to  be  used,  remove  this   negative  tare 
    value by pressing the  [Tare] key once more. 
     
      Any  time  the  weight  is  negative,  only  bars  will  be  shown  in  the 
    TOTAL  display “- - - - - “. 
     
    3.3 COIN COUNTING 
     
      To  count  coins  simply  place  the  coins  in  the  contai ner  and  press 
    the  key  corresponding  to  the  value  of  the  coin.  The   displays  will 
    immediately  show  the  denomination  selected  in  the  
    Denomination   window,  the  number  of  coins  in  the  Quantity 
    window and the value of the coins in the  TOTAL window. 
     
      The  Scale  determines  the  weight  of  the  coins  and  di vided  the 
    weight by the average weight for the denomination s elected.  This 
    determines  the  Quantity  of  coins.    The  total  value  is  the  quantity 
    multiplied by the denomination. 
     
      It  is  necessary  to  set  an  average  weight  into  memor y  before  any 
    of the token keys  [Tx] can be used.  See Sections 5.1 and 5.2 for 
    more details. 
      
    						
    							13 | P a g e    © Adam Equipment Company 2009 
      
    3.4 MEMORY
     ACCUMULATIONS 
     
     When  the  coins  have  been  counted  it  is  possible  to  store  the 
    results of this sample into memory by pressing  [M+].   
     
      The  displays  will  show  a  number  corresponding  to  th e  item 
    number  in  memory  ( Denomination  display  “1 ”)  and  the  total 
    quantity  of  coins  counted  in  memory  ( Quantity  display)  and  the 
    total  value  of  coins  that  have  been  stored  into  mem ory  (TOTAL  
    display). 
     
     For Example:
     
     “    0.20 ”   “    285”  “   57.00” 
      
    Press  [M+]   
     “  1   ”   “    285”  “   57.00” 
      
    After 2 seconds the scale will return to normal ope ration.  Put next 
    batch of coins on the scale, select denomination  [R1] 
     “   1.00 ”   “    108”  “   108.00” 
      
    Press [M+] 
     “  2   ”   “    393”  “   165.00 ” 
    After 2 seconds the scale will return to normal ope ration.  Put next 
    batch of coins, select denomination  [10c] 
     
     “   0.10 ”   “    105”  “     10.50” 
      
    						
    							14 | P a g e    © Adam Equipment Company 2009 
      
    Press [M+]  
     “  3   ”   “    498”  “   175.50” 
     
     After  2  seconds  the  scale  will  return  to  normal  ope ration.    The 
    weight  on  the  scale  must  return  to  zero  before  anot her  value  is 
    allowed to be stored into memory. 
     
    NOTE :    Tokens  cannot  be  added  to  memory  as  they  do  not  h ave  a  value 
    associated with them. 
     
     If tokens are to be added to memory with coins, an  error message 
    will be displayed:   
     
     “   ErrOr   ”    “   TYPE”    “       ” 
    After that the scale will return to normal operatio n.  
    						
    							15 | P a g e    © Adam Equipment Company 2009 
     
    3.5 MEMORY RECALL 
     
     Pressing  the  [MR] key  will  allow  you  to  view  each  set  of  data 
    stored into the memory.    
     The  first  time   [MR] is  pressed  the  first  set  of  data  is  shown  with 
    Denomination  window showing “  ≡ 1   ≡” for 1 second followed by 
    the  Denomination , Quantity   and TOTAL   windows  showing  the 
    quantity and value for this first item. 
     
    “   1   ”   “         ”  “             ” for 1 second and then 
        “      0.20”   “    285”  “     57.00” 
     Pressing  [MR] again will show the second set of data.  
      
     “   2   ”   “         ”  “             ” for 1 second and then 
    “      1.00”   “    108”  “   108.00” 
     Continue to press  [MR] until the total values from the memory are 
    shown: 
     
     
    “    3   ”  “  TotAL ”   “  175.50 ” 
    After 2 seconds the scale will return to normal ope ration. 
     
      If  [MC/  
    
    
    ]  is pressed when the total is shown-  
     
    “     3   ”  “    498”   “  175.50” as in the above example,   
      
    all data in the memory will be erased. The displays  will show Zero 
    and it will return to normal weighing after 2 secon ds. 
      
    						
    							16 | P a g e    © Adam Equipment Company 2009 
    4.0  RS-232 INTERFACE 
    The  Scale  includes  a  RS-232  output  as  standard.    The  RS-232  allows  a 
    record to be sent to a serial printer as work is do ne on the scale. 
      
    4.1  RS-232
     OUTPUT 
     
    The  RS-232  interface  is  bi-directional  with  command s  that  function  similar  to 
    some of the front panel keys and other commands to  input data into the scale 
    for  coin  weights,  denominations  and  symbols  used.    The  parameters  for  the 
    RS-232 interface are: 
     
      
    The scale does not require  RTS/CTS signals to be u sed.   
     
    4.2 PRINTING 
      
    The scale will output data when the following keys  are pressed.   
      
    [M+]  outputs  the  current  record  at  the  same  time  as  the  results  are  stored  in 
    the memory. See Section 3.4.  
    Baud Rate:   300, 600, 1200, 2400, 4800 or 9600 baud 
    Parity:    None, Odd or Even 
    Data bits:    8 or 7 
    Stop bit:    1 
    Data:     ASCII  
    Connector:   d-subminiature 9 pin socket (DE 9S)  
    Mating connector:  d-subminiature 9 pin plug (DE 9P)  
          Pin 2    RXD Data Input  
          Pin 3    TXD Signal Output 
          Pin 5    RTS Output 
          
    						
    							17 | P a g e    © Adam Equipment Company 2009 
      
    A display produced as shown in the previous example is as follows: 
     
    “    0.20 ”   “    285”  “   57.00” 
      
    Press  [M+]  
     
    “   1   ”   “    285”  “   57.00” 
         
      
    Printed record shows as follows: 
     
      
    Any  time  the  [Total  /
    
    
    ]  key  is  pressed  the  current  totals  held  in  memory  ar e 
    printed.    After  the  2
    nd  weighing  in  the  previous  sample,  the  printed  recor d 
    shows as follows:  
    Date:      2009/01/05  
    Time:        12:23:15  
    Record           1  
    Denomination     0.20 
    Quantity        285 
    Value    €     57.00 
     
    . . . . . . . . . . .  
    Date:      2009/01/05 
    Time:        12:23:15 
    Total  
    Quantity        498  
    Total  
    Value      €   175.50 
      
    						
    							18 | P a g e    © Adam Equipment Company 2009 
      
    The [MC/ 
    
    
    ]  key  is  active  when  the  total  values  are  displayed.   If [MC/ 
    
    
    ] is 
    pressed the memory will be cleared.   
    After 2 seconds the scale will return to normal ope ration.   
     
    The  [Print]   key  will  record  a  list  of  all  sets  of  data  stored  in  the  memory  and 
    the total amounts.  For the sample above, the print ed record is: 
     
     
     
    Date:      2009/01/05 
    Time:        12:23:15 
        
    Record        1  
    Denomination    0.20 
    Quantity     285  
    Value  €  57.00 
      
    Record        2  
    Denomination    1.00  
    Quantity     108  
    Value  €   108.00 
      
    Record        3 
    Denomination    0.10  
    Quantity     105  
    Value  €  10.50 
      
    . . . . . . . . . . .
     
    Total  
    Quantity     498  
    Total   
    Value     €   175.50  
    						
    All Adam Equipment manuals Comments (0)

    Related Manuals for Adam Equipment Coin Counting Scale CCSArevA1 User Manual