9 | P a g e © Adam Equipment Company 2009 2.6 BACKLIGHT OPERATION The LCD display has a backlight that operates autom atically. To maximise the battery life it may be necessary to tu rn the backlight off. Hold the [Print] key for 4 seconds to enter the backlight control mode. Use the [MC / ] key to change the setting for the backlight to OFF, ON (set to on for full time) or AUTO (set to o n only when there is a weight on the scale). 2.7 TEMPORARY WEIGHT DISPLAY Press and hold the [CE/Esc] key for 4 seconds for the display to change the weight in the Denomination window. Pressing any key except the [Tare] and [CE/Esc] keys will have no effect to the operation. Pressing [Tare] will operate as a Tare function and [CE/Esc] will return the scale to normal operation. 2.8 SETTING DATE AND TIME The Real Time Clock (RTC) is used only for the RS-2 32 output. The Date and Time can be set as required. The scale will ke ep the clock running even when the power is off. Setting up the clock Press and hold the [1c] key when power is first turned on, release the key when the revision is displayed. The initial di splays show the current date and time set. “ rtC “ “ 11,14,06 ” “16,41,35 ” Press the [CE] key to change the date and time. The display will show the current time format, “ H-m-S”. Enter the time using the numeric keys using a 24 h our clock format, 3:41PM is “ 154100”. Press the [Total/ ] key to accept the time. The display will show the current date format. Press the [MC/ ] key to change the date format. Available formats are:
10 | P a g e © Adam Equipment Company 2009 “Y-m-d ” year, month, day “ m-d-Y ” month, day, year “ d-m-Y ” day, month, year Press the [Total/ ] key to accept the chosen format and then enter the date in this format. Press the [Total/ ] key to accept the date. An error code will be shown if the time ( Err 1) or the date ( Err 2) is not the permissible values. For example, 34 th day of a month is an invalid entry.
11 | P a g e © Adam Equipment Company 2009 3.0 BASIC OPERATION 3.1 ZEROING THE DISPLAY Press the [>ZZZ
12 | P a g e © Adam Equipment Company 2009 When both the product and container are removed the Quantity and TOTAL display will show bars “- - - - -“ as the weight i s below zero. If a different container is to be used, remove this negative tare value by pressing the [Tare] key once more. Any time the weight is negative, only bars will be shown in the TOTAL display “- - - - - “. 3.3 COIN COUNTING To count coins simply place the coins in the contai ner and press the key corresponding to the value of the coin. The displays will immediately show the denomination selected in the Denomination window, the number of coins in the Quantity window and the value of the coins in the TOTAL window. The Scale determines the weight of the coins and di vided the weight by the average weight for the denomination s elected. This determines the Quantity of coins. The total value is the quantity multiplied by the denomination. It is necessary to set an average weight into memor y before any of the token keys [Tx] can be used. See Sections 5.1 and 5.2 for more details.
13 | P a g e © Adam Equipment Company 2009 3.4 MEMORY ACCUMULATIONS When the coins have been counted it is possible to store the results of this sample into memory by pressing [M+]. The displays will show a number corresponding to th e item number in memory ( Denomination display “1 ”) and the total quantity of coins counted in memory ( Quantity display) and the total value of coins that have been stored into mem ory (TOTAL display). For Example: “ 0.20 ” “ 285” “ 57.00” Press [M+] “ 1 ” “ 285” “ 57.00” After 2 seconds the scale will return to normal ope ration. Put next batch of coins on the scale, select denomination [R1] “ 1.00 ” “ 108” “ 108.00” Press [M+] “ 2 ” “ 393” “ 165.00 ” After 2 seconds the scale will return to normal ope ration. Put next batch of coins, select denomination [10c] “ 0.10 ” “ 105” “ 10.50”
14 | P a g e © Adam Equipment Company 2009 Press [M+] “ 3 ” “ 498” “ 175.50” After 2 seconds the scale will return to normal ope ration. The weight on the scale must return to zero before anot her value is allowed to be stored into memory. NOTE : Tokens cannot be added to memory as they do not h ave a value associated with them. If tokens are to be added to memory with coins, an error message will be displayed: “ ErrOr ” “ TYPE” “ ” After that the scale will return to normal operatio n.
15 | P a g e © Adam Equipment Company 2009 3.5 MEMORY RECALL Pressing the [MR] key will allow you to view each set of data stored into the memory. The first time [MR] is pressed the first set of data is shown with Denomination window showing “ ≡ 1 ≡” for 1 second followed by the Denomination , Quantity and TOTAL windows showing the quantity and value for this first item. “ 1 ” “ ” “ ” for 1 second and then “ 0.20” “ 285” “ 57.00” Pressing [MR] again will show the second set of data. “ 2 ” “ ” “ ” for 1 second and then “ 1.00” “ 108” “ 108.00” Continue to press [MR] until the total values from the memory are shown: “ 3 ” “ TotAL ” “ 175.50 ” After 2 seconds the scale will return to normal ope ration. If [MC/ ] is pressed when the total is shown- “ 3 ” “ 498” “ 175.50” as in the above example, all data in the memory will be erased. The displays will show Zero and it will return to normal weighing after 2 secon ds.
16 | P a g e © Adam Equipment Company 2009 4.0 RS-232 INTERFACE The Scale includes a RS-232 output as standard. The RS-232 allows a record to be sent to a serial printer as work is do ne on the scale. 4.1 RS-232 OUTPUT The RS-232 interface is bi-directional with command s that function similar to some of the front panel keys and other commands to input data into the scale for coin weights, denominations and symbols used. The parameters for the RS-232 interface are: The scale does not require RTS/CTS signals to be u sed. 4.2 PRINTING The scale will output data when the following keys are pressed. [M+] outputs the current record at the same time as the results are stored in the memory. See Section 3.4. Baud Rate: 300, 600, 1200, 2400, 4800 or 9600 baud Parity: None, Odd or Even Data bits: 8 or 7 Stop bit: 1 Data: ASCII Connector: d-subminiature 9 pin socket (DE 9S) Mating connector: d-subminiature 9 pin plug (DE 9P) Pin 2 RXD Data Input Pin 3 TXD Signal Output Pin 5 RTS Output
17 | P a g e © Adam Equipment Company 2009 A display produced as shown in the previous example is as follows: “ 0.20 ” “ 285” “ 57.00” Press [M+] “ 1 ” “ 285” “ 57.00” Printed record shows as follows: Any time the [Total / ] key is pressed the current totals held in memory ar e printed. After the 2 nd weighing in the previous sample, the printed recor d shows as follows: Date: 2009/01/05 Time: 12:23:15 Record 1 Denomination 0.20 Quantity 285 Value € 57.00 . . . . . . . . . . . Date: 2009/01/05 Time: 12:23:15 Total Quantity 498 Total Value € 175.50
18 | P a g e © Adam Equipment Company 2009 The [MC/ ] key is active when the total values are displayed. If [MC/ ] is pressed the memory will be cleared. After 2 seconds the scale will return to normal ope ration. The [Print] key will record a list of all sets of data stored in the memory and the total amounts. For the sample above, the print ed record is: Date: 2009/01/05 Time: 12:23:15 Record 1 Denomination 0.20 Quantity 285 Value € 57.00 Record 2 Denomination 1.00 Quantity 108 Value € 108.00 Record 3 Denomination 0.10 Quantity 105 Value € 10.50 . . . . . . . . . . . Total Quantity 498 Total Value € 175.50