Chapter 473 Error Message List No beep Error MessagesFRU/Action in Sequence No beep, power-on indicator turns off and LCD is blank.Power source (battery pack and power adapter). See “Power System Check” on page 67. Ensure every connector is connected tightly and correctly. Reconnect the DIMM. LED board. System board. No beep, power-on indicator turns on and LCD is blank.Power source (battery pack and power adapter). See “Power System Check” on page 67. Reconnect the LCD connector Hard disk drive LCD inverter ID LCD cable LCD Inverter LCD System board No beep, power-on indicator turns on and LCD is blank. But you can see POST on an external CRT. Reconnect the LCD connectors. LCD inverter ID LCD cable LCD inverter LCD System board No beep, power-on indicator turns on and a blinking cursor shown on LCD during POST.Ensure every connector is connected tightly and correctly. System board No beep during POST but system runs correctly. Speaker System board
74Chapter 4 Index of Symptom-to-FRU Error Message LCD-Related Symptoms Symptom / ErrorAction in Sequence LCD backlight doesnt work LCD is too dark LCD brightness cannot be adjusted LCD contrast cannot be adjustedEnter BIOS Utility to execute “Load Setup Default Settings”, then reboot system. Reconnect the LCD connectors. Keyboard (if contrast and brightness function key doesnt work). LCD inverter ID LCD cable LCD inverter LCD System board Unreadable LCD screen Missing pels in characters Abnormal screen Wrong color displayedReconnect the LCD connector LCD inverter ID LCD cable LCD inverter LCD System board LCD has extra horizontal or vertical lines displayed.LCD inverter ID LCD inverter LCD cable LCD System board Indicator-Related Symptoms Symptom / ErrorAction in Sequence Indicator incorrectly remains off or on, but system runs correctlyReconnect the inverter board Inverter board System board Power-Related Symptoms Symptom / ErrorAction in Sequence Power shuts down during operation Power source (battery pack and power adapter). See “Power System Check” on page 67. Battery pack Power adapter Hard drive & battery connection board System board The system doesn’t power-on. Power source (battery pack and power adapter). See “Power System Check” on page 67. Battery pack Power adapter Hard drive & battery connection board System board The system doesn’t power-off. Power source (battery pack and power adapter). See “Power System Check” on page 67. Hold and press the power switch for more than 4 seconds. System board Battery can’t be charged See “Check the Battery Pack” on page 69. Battery pack System board
Chapter 475 PCMCIA-Related Symptoms Symptom / ErrorAction in Sequence System cannot detect the PC Card (PCMCIA) PCMCIA slot assembly System board PCMCIA slot pin is damaged. PCMCIA slot assembly Memory-Related Symptoms Symptom / ErrorAction in Sequence Memory count (size) appears different from actual size.Enter BIOS Setup Utility to execute “Load Default Settings, then reboot system. DIMM System board Speaker-Related Symptoms Symptom / ErrorAction in Sequence In Windows, multimedia programs, no sound comes from the computer. Audio driver Speaker System board Internal speakers make noise or emit no sound. Speaker System board Power Management-Related Symptoms Symptom / ErrorAction in Sequence The system will not enter hibernation Keyboard (if control is from the keyboard) Hard disk drive System board The system doesnt enter hibernation mode and four short beeps every minute.See “Hibernation Mode” on page 24. Press Fn+F4 and see if the computer enters hibernation mode. Touchpad Keyboard Hard disk connection board Hard disk drive System board The system doesn’t enter standby mode after closing the LCDSee “Hibernation Mode” on page 24. LCD cover switch System board The system doesnt resume from hibernation mode.See “Hibernation Mode” on page 24. Hard disk connection board Hard disk drive System board The system doesnt resume from standby mode after opening the LCD.See “Standby Mode” on page 24. LCD cover switch System board Battery fuel gauge in Windows doesn’t go higher than 90%. Remove battery pack and let it cool for 2 hours. Refresh battery (continue use battery until power off, then charge battery). Battery pack System board
76Chapter 4 NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined Problems” on page 78. System hangs intermittently. See “Thermal & Fan Utility” on page 38. Reconnect hard disk/CD-ROM drives. Hard disk connection board System board Peripheral-Related Symptoms Symptom / ErrorAction in Sequence System configuration does not match the installed devices. Enter BIOS Setup Utility to execute “Load Default Settings”, then reboot system. Reconnect hard disk/CD-ROM/diskette drives. External display does not work correctly. Press Fn+F5, LCD/CRT/Both display switching See “System Diagnostic Diskette” on page 38. System board USB does not work correctly See “System Diagnostic Diskette” on page 38 System board Print problems. Ensure the “Parallel Port” in the “Onboard Devices Configuration” of BIOS Setup Utility is set to Enabled. Onboard Devices Configuration Run printer self-test. Printer driver Printer cable Printer System Board Serial or parallel port device problems. Ensure the “Serial Port” in the Devices Configuration” of BIOS Setup Utility is set to Enabled. Device driver Device cable Device System board Keyboard/Touchpad-Related Symptoms Symptom / ErrorAction in Sequence Keyboard (one or more keys) does not work. Reconnect the keyboard cable. Keyboard System board Touchpad does not work. Reconnect touchpad cable. Touchpad board System board Modem-Related Symptoms Symptom / ErrorAction in Sequence Internal modem does not work correctly. See “System Diagnostic Diskette” on page 38. Modem phone port modem combo board System board Power Management-Related Symptoms Symptom / ErrorAction in Sequence
Chapter 477 Intermittent Problems Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement should be considered only when a recurring problem exists. When analyzing an intermittent problem, do the following: 1. Run the advanced diagnostic test for the system board in loop mode at least 10 times. 2. If no error is detected, do not replace any FRU. 3. If any error is detected, replace the FRU. Rerun the test to verify that there are no more errors.
78Chapter 4 Undetermined Problems The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, whether a short circuit is suspected, or whether the system is inoperative. Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU). NOTE: Verify that all attached devices are supported by the computer. NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power System Check” on page 67): 1. Power-off the computer. 2. Visually check them for damage. If any problems are found, replace the FRU. 3. Remove or disconnect all of the following devices: !Non-Acer devices !Printer, mouse, and other external devices !Battery pack !Hard disk drive !DIMM !CD-ROM/Diskette drive Module !PC Cards 4. Power-on the computer. 5. Determine if the problem has changed. 6. If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU. 7. If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU: !System board !LCD assembly
Chapter 479 Index of AFlash BIOS Error Message Error MessageAction in Sequence Hardware Error See “System Diagnostic Diskette” on page 38 VPD Checksum Error Reboot the system and then restest with this diskette. BIOS Update Program Error Turn off the power and restart the system. System Error Make sure this AFlash BIOS diskette for this model. Without AC adapter make sure to connect AC adapter Battery Low make sure to install a highly charged battery, and reboot system.
80Chapter 4 Index of PQA Diagnostic Error Code, Message Error CodeMessageAction in Sequence 16XXX Backup battery error Backup battery 01XXX CPU or main board error Reload BIOS default setting. System board 02XXX Memory error DIMM System board 03XXX Keyboard error Reset Keyboard Keyboard System board 04XXX Video error System board 05XXX Parallel Port error System board 06XXX Serial port or main board error System board 07XXX Diskette drive error Diskette drive System board 08XXX Hard disk error Reload BIOS default setting Hard disk System board 09XXX CD-ROM error Reset CD-ROM cable CD-ROM drive System board 10XXX Co-processor error System board 11XXX Pointing device error Reset Keyboard Keyboard System board 12XXX Cache test error System board
Chapter 581 To p Vi e w VR1PH3 PH2PH1 CN13 CN8 U2 CN7 CN2 CN5 CN4 CN3 CN6 CN1 CN9 CN10 CN12 CN15 SW1 CN16 CN18 CN26 CN19 CN11 CN14 CN17 Jumper and Connector Locations Chapter 5
82Chapter 5 PCB 01200-S SW1 Settings VR1 Volume Control CN1 PS/2 Port PH3 Microphone-in Port CN9 LCD Cover Switch Connector PH2 Line-in Port CN10 LED/Inverter Board Connector PH1 Line-out Port CN12 External CD/DVD-ROM Module Connector CN13 Cardbus Socket CN15 Internal Keyboard Connector CN8 FAN Connector SW1 See SW1 Setting listed below U2 FIR CN16 Finger Print Check CN7 USB Port CN18 HDD Connector CN2 VGA Port CN26 Battery Connector CN5 LAN Connector (RJ45) CN19 Debug Board CN4 Parallel Port CN11 LCD FPC Connector CN3 Serial Port CN14 RTC Batteru Connector CN6 Modem Connector (RJ11) CN17 TouchPad Connector SW4Setting Switch 1 ON: Enable password check OFF: Disable password check Switch 2 ON: Enable BootBlock Erasable OFF: Disable BootBlock Erasable Switch 3 OFF: US keyboard ON: Japanese keyboard OFF: Europe keyboard OFF: US International keyboard Switch 4 OFF: US keyboard OFF: Japanese keyboard ON: Europe keyboard OFF: US International keyboard