    							Chapter 365
    21.Remove the USB board from BTCB. 
    						
    							66Chapter 3
    Disassembly LCM module
    1.Remove six LCM bezel mylar.
    2.Loose 10 LCM bezel screws.
    3.Remove LCM bezel.
    4.Disconnect Inverter cable and Back LED board cable.
    5.Remove Inverter from BTCB.
    6.Loose four LCD scrws from the hinge.
    7.Disconnect CCD cable.
    8.Remove the LCD panel. 
    						
    							Chapter 367
    9.Loose four LCD hinge screws, then remove two hinges from LCD panel.
    Disassembling the External Modules
    Disassembling the HDD Module
    1.Remove the four screws holding the HDD (hard disk drive) foil; two on each side.
    2.Carefully take out the hard disk drive from the HDD foil. 
    						
    							68Chapter 3
    Disassembling the ODD Module
    1.Remove the two screws holding the optical bracket.
    2.Then remove the optical bracket from the optical disk drive. 
    						
    							Chapter 469
    Use the following procedure as a guide for computer problems.
    NOTE: The diagnostic tests are intended to test only Acer products. Non-Acer products, prototype cards, or 
    modified options can give false errors and invalid system responses.
    1.Obtain the failing symptoms in as much detail as possible.
    2.Verify the symptoms by attempting to re-create the failure by running the diagnostic test or by repeating 
    the same operation.
    3.Use the following table with the verified symptom to determine which page to go to.
    Symptoms (Verified)Go To
    Power failure. (The power indicator does not 
    go on or stay on.)“Power System Check” on page 71.
    POST does not complete. No beep or error 
    codes are indicated.“Power-On Self-Test (POST) Error Message” 
    on page 73
    “Undetermined Problems” on page 88
    POST detects an error and displayed 
    messages on screen.“Error Message List” on page 74
    Other symptoms (i.e. LCD display problems or 
    others).“Power-On Self-Test (POST) Error Message” 
    on page 73
    Symptoms cannot be re-created (intermittent 
    problems).Use the customer-reported symptoms and go 
    to “Power-On Self-Test (POST) Error 
    Message” on page 73
    “Intermittent Problems” on page 87
    “Undetermined Problems” on page 88
    Troubleshooting
    Chapter 4 
    						
    							70Chapter 4
    System Check Procedures
    External Diskette Drive Check
    Do the following to isolate the problem to a controller, driver, or diskette. A write-enabled, diagnostic diskette is 
    required.
    NOTE: Make sure that the diskette does not have more than one label attached to it. Multiple labels can cause 
    damage to the drive or cause the drive to fail. 
    Do the following to select the test device.
    1.Boot from the diagnostics diskette and start the diagnostics program.
    2.See if FDD Test is passed as the program runs to FDD Test.
    3.Follow the instructions in the message window.
    If an error occurs with the internal diskette drive, reconnect the diskette connector on the system board.
    If the error still remains:
    1.Reconnect the external diskette drive/DVD-ROM module.
    2.Replace the external diskette drive/CD-ROM module.
    3.Replace the main board.
    External CD-ROM Drive Check
    Do the following to isolate the problem to a controller, drive, or CD-ROM. Make sure that the CD-ROM does 
    not have any label attached to it. The label can cause damage to the drive or can cause the drive to fail.
    Do the following to select the test device:
    1.Boot from the diagnostics diskette and start the diagnostics program.
    2.See if CD-ROM Test is passed when the program runs to CD-ROM Test.
    3.Follow the instructions in the message window.
    If an error occurs, reconnect the connector on the System board. If the error still remains:
    1.Reconnect the external diskette drive/CD-ROM module.
    2.Replace the external diskette drive/CD-ROM module.
    3.Replace the main board.
    Keyboard or Auxiliary Input Device Check
    Remove the external keyboard if the internal keyboard is to be tested.
    If the internal keyboard does not work or an unexpected character appears, make sure that the flexible cable 
    extending from the keyboard is correctly seated in the connector on the system board.
    If the keyboard cable connection is correct, run the Keyboard Test. 
    If the tests detect a keyboard problem, do the following one at a time to correct the problem. Do not replace a 
    non-defective FRU:
    1.Reconnect the keyboard cables.
    2.Replace the keyboard.
    3.Replace the main board.
    The following auxiliary input devices are supported by this computer:
    ‰Numeric keypad
    ‰External keyboard
    If any of these devices do not work, reconnect the cable connector and repeat the failing operation.  
    						
    							Chapter 471
    Memory check
    Memory errors might stop system operations, show error messages on the screen, or hang the system.
    1.Boot from the diagnostics diskette and start the doagmpstotics program (please refer to main board.
    2.Go to the diagnostic memory in the test items.
    3.Press F2 in the test items.
    4.Follow the instructions in the message window.
    NOTE: Make sure that the DIMM is fully installed into the connector. A loose connection can cause an error.
    Power System Check
    To verify the symptom of the problem, power on the computer using each of the following power sources:
    1.Remove the battery pack.
    2.Connect the power adapter and check that power is supplied.
    3.Disconnect the power adapter and install the charged battery pack; then check that power is supplied by 
    the battery pack.
    If you suspect a power problem, see the appropriate power supply check in the following list:
    ‰“Check the Power Adapter” on page 71
    ‰“Check the Battery Pack” on page 71
    Check the Power Adapter
    Unplug the power adapter cable from the computer and measure the output voltage at the plug of the power 
    adapter cable. See the following figure
    1.If the voltage is not correct, replace the power adapter.
    2.If the voltage is within the range, do the following:
    zReplace the System board.
    zIf the problem is not corrected, see “Undetermined Problems” on page 88.
    zIf the voltage is not correct, go to the next step.
    NOTE: An audible noise from the power adapter does not always indicate a defect.
    3.If the power-on indicator does not light up, check the power cord of the power adapter for correct 
    continuity and installation.
    4.If the operational charge does not work, see “Check the Battery Pack” on page 71. 
    Check the Battery Pack 
    To check the battery pack, do the following:
    From Software:
    1.Check out the Power Management in control Panel
    2.In Power Meter, confirm that if the parameters shown in the screen for Current Power Source and Total 
    Battery Power Remaining are correct.
    3.Repeat the steps 1 and 2, for both battery and adapter.
    4.This helps you identify first the problem is on recharging or discharging. 
    Pin 1: +19 to +20.5V
    Pin 2: 0V, Ground 
    						
    							72Chapter 4
    From Hardware:
    1.Power off the computer. 
    2.Remove the battery pack and measure the voltage between battery terminals 1(+) and 6(ground). See the 
    following figure
    3.If the voltage is still less than 7.5 Vdc after recharging, replace the battery. 
    To check the battery charge operation, use a discharged battery pack or a battery pack that has less than 50% 
    of the total power remaining when installed in the computer. 
    If the battery status indicator does not light up, remove the battery pack and let it return to room temperature. 
    Re-install the battery pack.
    If the charge indicator still does not light up, replace the battery pack. If the charge indicator still does not light 
    up, replace the DC/DC charger board. 
    Touchpad Check
    If the touchpad doesn’t work, do the following actions one at a time to correct the problem. Do not replace a 
    non-defective FRU:
    1.Reconnect the touchpad cables.
    2.Replace the touchpad.
    3.Replace the system board.
    After you use the touchpad, the pointer drifts on the screen for a short time. This self-acting pointer movement 
    can occur when a slight, steady pressure is applied to the touchpad pointer. This symptom is not a hardware 
    problem. No service actions are necessary if the pointer movement stops in a short period of time. 
    						
    							Chapter 473
    Power-On Self-Test (POST) Error Message 
    The POST error message index lists the error message and their possible causes. The most likely cause is 
    listed first.
    NOTE: Perform the FRU replacement or actions in the sequence shown in FRU/Action column, if the FRU 
    replacement does not solve the problem, put the original part back in the computer. Do not replace a 
    non-defective FRU.
    This index can also help you determine the next possible FRU to be replaced when servicing a computer.
    If the symptom is not listed, see “Undetermined Problems” on page 88.
    The following lists the error messages that the BIOS displays on the screen and the error symptoms classified 
    by function. 
    NOTE: Most of the error messages occur during POST. Some of them display information about a hardware 
    device, e.g., the amount of memory installed. Others may indicate a problem with a device, such as the 
    way it has been configured. 
    NOTE: If the system fails after you make changes in the BIOS Setup Utility menus, reset the computer, enter 
    Setup and install Setup defaults or correct the error.  
    						
    							74Chapter 4
    Index of Error Messages
    Error Code List
    Error Message List
    Error CodesError Messages
    006 Equipment Configuration Error
    Causes:
    1. CPU BIOS Update Code Mismatch
    2. IDE Primary Channel Master Drive Error
    (THe causes will be shown before “Equipment 
    Configuration Error”)
    010 Memory Error at xxxx:xxxx:xxxxh (R:xxxxh, 
    W:xxxxh) 
    070 Real Time Clock Error
    071 CMOS Battery Bad
    072 CMOS Checksum Error
    110 System disabled.
    Incorrect password is specified.
     Battery critical LOW
    In this situation BIOS will issue 4 short beeps 
    then shut down system, no message will show.
     Thermal critical High
    In this situation BIOS will shut down system, 
    not show message.
    Error MessagesFRU/Action in Sequence
    Failure Fixed Disk Reconnect hard disk drive connector.
    “Load Default Settings” in BIOS Setup Utility.
    Hard disk drive
    System board
    Stuck Key see “Keyboard or Auxiliary Input Device 
    Check” on page 70. 
    Keyboard error see “Keyboard or Auxiliary Input Device 
    Check” on page 70. 
    Keyboard Controller Failed see “Keyboard or Auxiliary Input Device 
    Check” on page 70. 
    Keyboard locked - Unlock key switch Unlock external keyboard
    Monitor type does not match CMOS - Run 
    SetupRun “Load Default Settings” in BIOS Setup 
    Utility.
    Shadow RAM Failed at offset: nnnn BIOS ROM
    System board
    System RAM Failed at offset: nnnn DIMM
    System board
    Extended RAM Failed at offset: nnnn DIMM
    System board
    System battery is dead - Replace and run 
    SetupReplace RTC battery and Run BIOS Setup 
    Utility to reconfigure system time, then reboot 
    system. 
    						