    							65Chapter 3
    HDD Disassembly
    1.Remove the four screws securing the HDD bracket.
    2.Remove the HDD from the HDD bracket. 
    						
    							Chapter 366
    ODD Disassembly
    1.Remove the two screws securing the ODD bracket.
    2.Remove the ODD bracket from the ODD. 
    						
    							67Chapter 3 
    						
    							Chapter 467
    Use the following procedure as a guide for computer problems.
    NOTE: The diagnostic tests are intended to test this model.  Non-Acer products, prototype cards, or modified 
    options can give false errors and invalid system responses.
    1.Duplicate symptom and obtain the failing symptoms in as much detail as possible.
    2.Distinguish symptom. Verify the symptoms by attempting to re-create the failure by running the diagnostic 
    test or by repeating the same operation.
    3.Disassemble and assemble the unit without any power sources.
    4.If any problem occurs, you can perform visual inspection before you fellow this chapter’s instructions. You 
    can check the following:
    power cords are properly connected and secured;
    there are no obvious shorts or opens;
    there are no obviously burned or heated components;
    all components appear normal.
    5.Use the following table with the verified symptom to determine which page to go to.
    Symptoms (Verified)Go To
    Power failure. (The power indicator does not go 
    on or stay on.)“Power System Check” on page 69.
    POST does not complete. No beep or error 
    codes are indicated.“Power-On Self-Test (POST) Error Message” on 
    page 71
    “Undetermined Problems” on page 83
    POST detects an error and displayed messages 
    on screen.“Error Message List” on page 72
    Other symptoms (i.e. LCD display problems or 
    others).“Power-On Self-Test (POST) Error Message” on 
    page 71
    Symptoms cannot be re-created (intermittent 
    problems).Use the customer-reported symptoms and go to 
    “Power-On Self-Test (POST) Error Message” on 
    page 71
    “Intermittent Problems” on page 82
    “Undetermined Problems” on page 83
    Troubleshooting
    Chapter 4 
    						
    							68Chapter 4
    System Check Procedures
    External Diskette Drive Check
    If an error occurs with the internal diskette drive, reconnect the diskette connector on the system board.
    If the error still remains:
    1.Reconnect the external diskette drive/DVD-ROM module.
    2.Replace the external diskette drive/CD-ROM module.
    3.Replace the main board.
    External CD-ROM Drive Check
    Do the following to isolate the problem to a controller, drive, or CD-ROM. Make sure that the CD-ROM does 
    not have any label attached to it. The label can cause damage to the drive or can cause the drive to fail.
    Do the following to select the test device:
    1.Boot from the diagnostics diskette and start the diagnostics program.
    2.See if CD-ROM Test is passed when the program runs to CD-ROM Test.
    3.Follow the instructions in the message window.
    If an error occurs, reconnect the connector on the System board. If the error still remains:
    1.Reconnect the external diskette drive/CD-ROM module.
    2.Replace the external diskette drive/CD-ROM module.
    3.Replace the main board.
    Keyboard or Auxiliary Input Device Check
    Remove the external keyboard if the internal keyboard is to be tested.
    If the internal keyboard does not work or an unexpected character appears, make sure that the flexible cable 
    extending from the keyboard is correctly seated in the connector on the system board.
    If the keyboard cable connection is correct, run the Keyboard Test.
    If the tests detect a keyboard problem, do the following one at a time to correct the problem. Do not replace a 
    non-defective FRU:
    1.Reconnect the keyboard cables.
    2.Replace the keyboard.
    3.Replace the main board.
    The following auxiliary input devices are supported by this computer:
    TNumeric keypad
    TExternal keyboard
    If any of these devices do not work, reconnect the cable connector and repeat the failing operation. 
    Memory check
    Memory errors might stop system operations, show error messages on the screen, or hang the system.
    1.Boot from the diagnostics diskette and start the doagmpstotics program (please refer to main board.
    2.Go to the diagnostic memory in the test items.
    3.Press F2 in the test items.
    4.Follow the instructions in the message window.
    NOTE: Make sure that the DIMM is fully installed into the connector. A loose connection can cause an error. 
    						
    							Chapter 469
    Power System Check
    To verify the symptom of the problem, power on the computer using each of the following power sources:
    1.Remove the battery pack.
    2.Connect the power adapter and check that power is supplied.
    3.Disconnect the power adapter and install the charged battery pack; then check that power is supplied by 
    the battery pack.
    If you suspect a power problem, see the appropriate power supply check in the following list:
    T“Check the Battery Pack” on page 70 
    						
    							70Chapter 4
    Check the Battery Pack
    To check the battery pack, do the following:
    From Software:
    1.Check out the Power Management in control Panel
    2.In Power Meter, confirm that if the parameters shown in the screen for Current Power Source and Total 
    Battery Power Remaining are correct.
    3.Repeat the steps 1 and 2, for both battery and adapter.
    4.This helps you identify first the problem is on recharging or discharging.
    From Hardware:
    1.Power off the computer. 
    2.Remove the battery pack and measure the voltage between battery terminals 1(+) and 6(ground). See the 
    following figure
    3.If the voltage is still less than 7.5 Vdc after recharging, replace the battery. 
    To check the battery charge operation, use a discharged battery pack or a battery pack that has less than 50% 
    of the total power remaining when installed in the computer. 
    If the battery status indicator does not light up, remove the battery pack and let it return to room temperature. 
    Re-install the battery pack.
    If the charge indicator still does not light up, replace the battery pack. If the charge indicator still does not light 
    up, replace the DC/DC charger board. 
    Touchpad check
    If the touchpad doesn’t work, do the following actions one at a time to correct the problem. Do not replace a 
    non-defective FRU:
    1.After rebooting, run Tracking Pad PS2 Mode Driver. For example, run Syn touch driver.
    2.Run utility with the PS/2 mouse function and check if the mouse is working.
    3.If the PS/2 mouse does not work, then check if the main board to switch board FPC is connected O.K.
    4.If the main board to switch board FPC is connected well, then check if the FCC on touch pad PCB 
    connects properly.
    5.If the FFC on touch pad PCB connects properly, then check if LS851 JP1 Pin6=5V are pulese. If yes, then 
    replace switch board. If no, then go to next step.
    6.Replace touch pad PCB.
    7.If the touch pad still does not work, then replace FPC on Track Pad PCB.
    After you use the touchpad, the pointer drifts on the screen for a short time. This self-acting pointer movement 
    can occur when a slight, steady pressure is applied to the touchpad pointer. This symptom is not a hardware 
    problem. No service actions are necessary if the pointer movement stops in a short period of time. 
    						
    							Chapter 471
    Power-On Self-Test (POST) Error Message
    The POST error message index lists the error message and their possible causes. The most likely cause is 
    listed first.
    NOTE: Perform the FRU replacement or actions in the sequence shown in FRU/Action column, if the FRU 
    replacement does not solve the problem, put the original part back in the computer. Do not replace a 
    non-defective FRU.
    This index can also help you determine the next possible FRU to be replaced when servicing a computer.
    If the symptom is not listed, see “Undetermined Problems” on page 83.
    The following lists the error messages that the BIOS displays on the screen and the error symptoms classified 
    by function. 
    NOTE: Most of the error messages occur during POST. Some of them display information about a hardware 
    device, e.g., the amount of memory installed. Others may indicate a problem with a device, such as the 
    way it has been configured.
    NOTE: If the system fails after you make changes in the BIOS Setup Utility menus, reset the computer, enter 
    Setup and install Setup defaults or correct the error.  
    						
    							72Chapter 4
    Index of Error Messages
    Error Message List
    Error MessagesFRU/Action in Sequence
    Struck Key See “Keyboard or Auxiliary Input Device Check” on page 68
    System CMOS checksum bad - Default 
    configuration usedRTC battery
    Run BIOS Setup Utility to reconfigure system, then reboot system.
    Real time clock error RTC battery
    Run BIOS Setup Utility to reconfigure system time, then reboot 
    system.
    Main board
    Previous boot incomplete - Default configuration 
    used“Load Default Settings” in BIOS Setup Utility.
    RTC battery
    Main baord
    Invalid System Configuration Data “Load Default Settings” in BIOS Setup Utility.
    Main board
    Operating system not found Enter Setup and see if fixed disk and drive A are properly identified.
    Dikette drive
    Hard disk drive
    Main board 
    						
    							Chapter 473
    Error Message List
    No beep Error MessagesFRU/Action in Sequence
    Power-on indicator turns off and LCD is blank. Power source (battery pack and power adapter.) See “Power 
    System Check” on page 69
    Ensure every connector is connected tightly and correctly.
    Reconnect the DIMM.
    Main board.
    Power-on indicator turns on and LCD is blank. Power source (battery pack and power adapter.) See “Power 
    System Check” on page 69
    Reconnect the LCD connector
    Hard disk drive
    LCD cable
    LCD inverter
    LCD
    Main board
    Power-on indicator turns on and LCD is blank. 
    But you can see POST on an external CRT.Reconnect the LCD connectors.
    LCD cable
    LCD inverter
    LCD
    Main board
    Power-on indicator turns on and a blinking cursor 
    shown on LCD during POST.Ensure every connector is connected tightly and correctly.
    Main board 
    						