    9.Pull the RF cable through the opening in the lower case as shown.
    10. Remove the screw holding the RF board to the lower case.
    11 . Take out the RF board from the lower case, then de tach the RF cable from the RF board as shown.
    12. Remove the RJ-11 jack from the lower case.
    NOTE:  RF board on selected models only.
    13. Remove the screw fastening the main board to the lower case.
    14. Detach the main board from the lower case as shown.
    15. Turn the main board over, then remove th e DC-in connector from the board as shown. 
    						
    							66Chapter 3
    Disassembling the Upper Case Assembly
    1.Turn the upper case over.
    2. Remove the two screws fastening the button board.
    3. Detach the button board with FFC from the upper case as shown.
    4. Remove the two screws fastening the LED board.
    5. Detach the LED board with FFC from the upper case as shown.
    6. Remove the two screws fastening the left speaker.
    7. Remove the left speaker from the upper case as shown. 
    						
    							Chapter 367
    Disassembling the LCD Module
    1.Remove the four screw rubbers as shown.
    2. Then remove the four screws fastening the LCD bezel.
    3. Detach the LCD bezel from the LCD module carefully.
    4. Remove the four screws holding the LCD to the LCD panel.
    5. Detach the CCD cable connector from the CCD board.
    6. Take out the CCD module from the LCD panel.
    7. Remove the screw fastening the CCD board to the CCD bracket.
    8. Lift out the LCD from the LCD panel as shown.
    9. Detach the two inverter cable con nectors from the inverter board.
    10. Remove the four screws fastening t he left LCD bracket and detach it.
    11 . Remove the four screws fastening the  right LCD bracket and detach it.
    12. Disconnect the LCD cable from the rear side of the LCD. 
    						
    							Chapter 369
    Disassembling the External Modules
    Disassembling the HDD Module
    1.Remove the four screws holding the HDD ( hard disk drive) case; two on each side.
    2. Carefully slide out the hard disk drive from the HDD case.
    Disassembling the ODD Module
    1.Remove the three screws holding the optical bracket.
    2. Then remove the optical bracket from the optical disk drive. 
    						
    							Chapter 471
    Use the following procedure as a guide for computer problems.
    NOTE: The diagnostic tests are intended to test only Acer  products. Non-Acer products, prototype cards, or 
    modified options can give false e rrors and invalid system responses.
    1. Obtain the failing symptoms in as much detail as possible.
    2. Verify the symptoms by attempting to re-create the fa ilure by running the diagnostic test or by repeating 
    the same operation.
    3. Use the following table with the verified symptom to determine which page to go to.
    Symptoms (Verified)Go To
    Power failure (The power indicator does not go 
    on or stay on). “Power System Check” on page 73
    POST does not complete. No beep or error 
    codes are indicated. “Power-On Self-Test (POST) Error Message” on 
    page 76
    “Undetermined Problems” on page 88
    POST detects an error and displayed messages 
    on screen. “Error Message List” on page 77
    Other symptoms (i.e. LCD display problems or 
    others). “Power-On Self-Test (POST) Error Message” on 
    page 76
    Symptoms cannot be re-created (intermittent 
    problems). Use the customer-reported symptoms and go to 
    “Power-On Self-Test (POST) Error Message” on 
    page 76
    “Intermittent Problems” on page 87
    “Undetermined Problems” on page 88
    Troubleshooting
    Chapter 4 
    						
    							72Chapter 4
    System Check Procedures
    External Diskette Drive Check
    Do the following to isolate the problem to a controller, driver, or diskette. A write-enabled, diagnostic diskette is 
    required.
    NOTE:  Make sure that the diskette does not have more than on e label attached to it. Multiple labels can cause 
    damage to the drive or cause the drive to fail. 
    Do the following to select the test device:
    1. Boot from the diagnostics diskette and start the diagnostics program.
    2. See if FDD Test is passed as the program runs to FDD Test.
    3. Follow the instructions in the message window.
    If an error occurs with the internal diskette drive,  reconnect the diskette connector on the system board.
    If the error still remains:
    1. Reconnect the external diskette drive/DVD-ROM module.
    2. Replace the external diskette drive/CD-ROM module.
    3. Replace the main board.
    External CD-ROM Drive Check
    Do the following to isolate the problem to a controller,  drive, or CD-ROM. Make sure that the CD-ROM does 
    not have any label attached to it. The label can caus e damage to the drive or can cause the drive to fail.
    Do the following to select the test device:
    1. Boot from the diagnostics diskette and start the diagnostics program.
    2. See if CD-ROM Test is passed when  the program runs to CD-ROM Test.
    3. Follow the instructions in the message window.
    If an error occurs, reconnect the connector on  the System board. If the error still remains:
    1. Reconnect the external diskette drive/CD-ROM module.
    2. Replace the external diskette drive/CD-ROM module.
    3. Replace the main board.
    Keyboard or Auxiliary Input Device Check
    Remove the external keyboard if the internal keyboard is to be tested.
    If the internal keyboard does not work or an unexpected  character appears, make sure that the flexible cable 
    extending from the keyboard is correctly se ated in the connector on the system board.
    If the keyboard cable connection is  correct, run the Keyboard Test. 
    If the tests detect a keyboard problem, do the following  one at a time to correct the problem. Do not replace a 
    non-defective FRU:
    1. Reconnect the keyboard cables.
    2. Replace the keyboard.
    3. Replace the main board.
    The following auxiliary input devices are supported by this computer:
    TNumeric keypad
    TExternal keyboard 
    						
    							Chapter 473
    If any of these devices do not work, reconnect the cable connector and repeat the failing operation. 
    Memory check
    Memory errors might stop system operations, show error messages on the screen, or hang the system.
    1.Boot from the diagnostics diskette and start the doa gmpstotics program (please refer to main board).
    2. Go to the diagnostic memory in the test items.
    3. Press F2 in the test items.
    4. Follow the instructions in the message window.
    NOTE:  Make sure that the DIMM is fully installed into  the connector. A loose connection can cause an error.
    Power System Check
    To verify the symptom of the problem, power on the co mputer using each of the following power sources:
    1. Remove the battery pack.
    2. Connect the power adapter and check that power is supplied.
    3. Disconnect the power adapter and install the charged ba ttery pack; then check that power is supplied by 
    the battery pack.
    If you suspect a power problem, see the appropriate power supply check in the following list:
    T“Check the Power Adapter” on page 74
    T“Check the Battery Pack” on page 75 
    						
    							74Chapter 4
    Check the Power Adapter
    Unplug the power adapter cable from the computer and measure the output voltage at the plug of the power 
    adapter cable. See the following figure:
    1. If the voltage is not correct, replace the power adapter.
    2. If the voltage is within the range, do the following:
    TReplace the System board.
    TIf the problem is not corrected, s ee “Undetermined Problems” on page 88.
    TIf the voltage is not correct, go to the next step.
    NOTE:  An audible noise from the power adapter does not always indicate a defect.
    3. If the power-on indicator does not light up, check the power cord of the power adapter for correct 
    continuity and installation.
    4. If the operational charge does not work, see “Check the Battery Pack” on page 75. 
    Pin 1: +19 to +20.5V
    Pin 2: 0V, Ground 
    						