Acer Aspire 5538 Service Guide
Here you can view all the pages of manual Acer Aspire 5538 Service Guide. The Acer manuals for Notebook are available online for free. You can easily download all the documents as PDF.
Page 171
161Chapter 4 ODD Failure If the ODD fails, perform the following actions one at a time to correct the problem. Do not replace a non- defective FRUs: ODD Not Operating Correctly If the ODD exhibits any of the following symptoms it may be faulty: • Audio CDs do not play when loaded • DVDs do not play when loaded • Blank discs do not burn correctly • DVD or CD play breaks up or jumps • Optical drive not found or not active: • Not shown in My Computer or the BIOS setup • LED does not flash when the...
Page 172
Chapter 4162 4.Navigate to Start´ Control Panel´ System and Maintenance´ System´ Device Manager. a.Double-click lDE ATA/ATAPI controllers. If a device displays a down arrow, right-click on the device and click Enable. b.Double-click DVD/CD-ROM drives. If the device displays a down arrow, right-click on the device and click Enable. c.Check that there are no yellow exclamation marks against the items in l D E ATA / ATA P I c o n t r o l l e r s. If a device has an exclamation mark, right-click on the...
Page 173
163Chapter 4 a.Navigate to Start´ Control Panel´ System and Maintenance´ System´ Device Manager. b.Double-click IDE ATA/ATAPI controllers, then right-click ATA Device 0. c.Click Properties and select the Advanced Settings tab. Ensure that the Enable DMA box is checked and click OK. d.Repeat for the other ATA Devices shown if applicable. Drive Not Detected If Windows cannot detect the drive, perform the following actions one at a time to correct the problem. 1.Restart the computer and press F2 to enter...
Page 174
Chapter 4164 USB Failure (Right side) If the rightside USB port fails, perform the following actions one at a time to correct the problem. Do not replace a non-defective FRUs:
Page 175
165Chapter 4 Wireless Function Failure If the WLAN/WiMAX fails, perform the following actions one at a time to correct the problem. Do not replace a non-defective FRUs: Start Reconnect the Antenna to the cardCheck Antenna to WLAN/WiMAX C ard Check AntennaSwap the Antenna Check WLAN/Wi MAX CardSwap WL AN/ WiMAX Card Check Function BoardSwap Function Board Swap Mainboard OK OK OK OK NG NG NG NG
Page 176
Chapter 4166 Bluetooth Function Failure If the Bluetooth fails, perform the following actions one at a time to correct the problem. Do not replace a non- defective FRUs: Easy Button Failure If the Media Board fails, perform the following actions one at a time to correct the problem. Do not replace a non-defective FRUs: Start Reconnect the cable to the moduleCheck BT cable connected Check BT cableSwap the cable Check BT ModuleSwap BT Module Check Function BoardSwap Function Board Swap Mainboard OK OK OK...
Page 177
167Chapter 4 Thermal Unit Failure If the Thermal Unit fails, perform the following actions one at a time to correct the problem. Do not replace a non-defective FRUs: Start Reconnect the cable to the MainboardCheck Fan pow er cable Check FanSwap the Therm al Module CPU Heatink w ell seat ed?Seat it well Check CPUSwap CPU Swap Mainboard OK OK OK OK NG NG NG NG
Page 178
Chapter 4168 External Mouse Failure If an external Mouse fails, perform the following actions one at a time to correct the problem. 1.Try an alternative mouse. 2.If the mouse uses a wireless connection, insert new batteries and confirm there is a good connection. See the mouse user manual. 3.If the mouse uses a USB connection, try an alternate USB port. 4.Try an alternative program to verify mouse operation. Reinstall the program experiencing mouse failure. 5.Restart the computer. 6.Remove any recently...
Page 179
169Chapter 4 Undetermined Problems The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, whether a short circuit is suspected, or whether the system is inoperative. Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU). NOTE: Verify that all attached devices are supported by the computer. NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power On Issue” on...
Page 180
Chapter 4170 POST Code Tables These tables describe the POST codes and descriptions during the POST. Sec NO_EVICTION_MODE_DEBUG EQU 1 (CommonPlatform\sec\Ia32\SecCore.inc) Memory DEBUG_BIOS equ 1 (Chipset\Alviso\MemoryInitAsm\IA32\IMEMORY.INC) Post CodeDescription 0xC2 MTRR setup 0xC3 Enable cache 0xC4 Establish cache tags 0xC5 Enter NEM, Place the BSP in No Fill mode, set CR0.CD = 1, CR0.NW = 0. 0xCF Cache Init Finished Post CodeDescription 0xA0 First memory check point 0x01 Enable MCHBAR 0x02 Check for...