Acer Aspire 3690 Service Guide
Have a look at the manual Acer Aspire 3690 Service Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 720 Acer manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Chapter 473 Use the following procedure as a guide for computer problems. NOTE: The diagnostic tests are intended to test only Acer products. Non-Acer products, prototype cards, or modified options can give false errors and invalid system responses. 1.Obtain the failing symptoms in as much detail as possible. 2.Verify the symptoms by attempting to re-create the failure by running the diagnostic test or by repeating the same operation. 3.Use the following table with the verified symptom to determine which page to go to. Symptoms (Verified)Go To Power failure. (The power indicator does not go on or stay on.)“Power System Check” on page 69. POST does not complete. No beep or error codes are indicated.“Power-On Self-Test (POST) Error Message” on page 72 “Undetermined Problems” on page 84 POST detects an error and displayed messages on screen.“Error Message List” on page 73 Other symptoms (i.e. LCD display problems or others).“Power-On Self-Test (POST) Error Message” on page 72 Symptoms cannot be re-created (intermittent problems).Use the customer-reported symptoms and go to “Power-On Self-Test (POST) Error Message” on page 72 “Intermittent Problems” on page 83 “Undetermined Problems” on page 84 Troubleshooting Chapter 4
74Chapter 4 System Check Procedures External Diskette Drive Check Do the following to isolate the problem to a controller, driver, or diskette. A write-enabled, diagnostic diskette is required. NOTE: Make sure that the diskette does not have more than one label attached to it. Multiple labels can cause damage to the drive or cause the drive to fail. Do the following to select the test device. 1.Boot from the diagnostics diskette and start the diagnostics program. 2.See if FDD Test is passed as the program runs to FDD Test. 3.Follow the instructions in the message window. If an error occurs with the internal diskette drive, reconnect the diskette connector on the system board. If the error still remains: 1.Reconnect the external diskette drive/DVD-ROM module. 2.Replace the external diskette drive/CD-ROM module. 3.Replace the main board. External CD-ROM Drive Check Do the following to isolate the problem to a controller, drive, or CD-ROM. Make sure that the CD-ROM does not have any label attached to it. The label can cause damage to the drive or can cause the drive to fail. Do the following to select the test device: 1.Boot from the diagnostics diskette and start the diagnostics program. 2.See if CD-ROM Test is passed when the program runs to CD-ROM Test. 3.Follow the instructions in the message window. If an error occurs, reconnect the connector on the System board. If the error still remains: 1.Reconnect the external diskette drive/CD-ROM module. 2.Replace the external diskette drive/CD-ROM module. 3.Replace the main board. Keyboard or Auxiliary Input Device Check Remove the external keyboard if the internal keyboard is to be tested. If the internal keyboard does not work or an unexpected character appears, make sure that the flexible cable extending from the keyboard is correctly seated in the connector on the system board. If the keyboard cable connection is correct, run the Keyboard Test. If the tests detect a keyboard problem, do the following one at a time to correct the problem. Do not replace a non-defective FRU: 1.Reconnect the keyboard cables. 2.Replace the keyboard. 3.Replace the main board. The following auxiliary input devices are supported by this computer: TNumeric keypad TExternal keyboard
Chapter 475 If any of these devices do not work, reconnect the cable connector and repeat the failing operation. Memory check Memory errors might stop system operations, show error messages on the screen, or hang the system. 1.Boot from the diagnostics diskette and start the doagmpstotics program (please refer to main board. 2.Go to the diagnostic memory in the test items. 3.Press F2 in the test items. 4.Follow the instructions in the message window. NOTE: Make sure that the DIMM is fully installed into the connector. A loose connection can cause an error. Power System Check To verify the symptom of the problem, power on the computer using each of the following power sources: 1.Remove the battery pack. 2.Connect the power adapter and check that power is supplied. 3.Disconnect the power adapter and install the charged battery pack; then check that power is supplied by the battery pack. If you suspect a power problem, see the appropriate power supply check in the following list: T“Check the Power Adapter” on page 70 T“Check the Battery Pack” on page 71
76Chapter 4 Check the Power Adapter Unplug the power adapter cable from the computer and measure the output voltage at the plug of the power adapter cable. See the following figure 1.If the voltage is not correct, replace the power adapter. 2.If the voltage is within the range, do the following: TReplace the System board. TIf the problem is not corrected, see “Undetermined Problems” on page 84. TIf the voltage is not correct, go to the next step. NOTE: An audible noise from the power adapter does not always indicate a defect. 3.If the power-on indicator does not light up, check the power cord of the power adapter for correct continuity and installation. 4.If the operational charge does not work, see “Check the Battery Pack” on page 71. Pin 1: +19 to +20.5V Pin 2: 0V, Ground
Chapter 477 Check the Battery Pack To check the battery pack, do the following: From Software: 1.Check out the Power Management in control Panel 2.In Power Meter, confirm that if the parameters shown in the screen for Current Power Source and Total Battery Power Remaining are correct. 3.Repeat the steps 1 and 2, for both battery and adapter. 4.This helps you identify first the problem is on recharging or discharging. From Hardware: 1.Power off the computer. 2.Remove the battery pack and measure the voltage between battery terminals 1(+) and 6(ground). See the following figure 3.If the voltage is still less than 7.5 Vdc after recharging, replace the battery. To check the battery charge operation, use a discharged battery pack or a battery pack that has less than 50% of the total power remaining when installed in the computer. If the battery status indicator does not light up, remove the battery pack and let it return to room temperature. Re-install the battery pack. If the charge indicator still does not light up, replace the battery pack. If the charge indicator still does not light up, replace the DC/DC charger board. Touchpad Check If the touchpad doesn’t work, do the following actions one at a time to correct the problem. Do not replace a non-defective FRU: 1.Reconnect the touchpad cables. 2.Replace the touchpad. 3.Replace the system board. After you use the touchpad, the pointer drifts on the screen for a short time. This self-acting pointer movement can occur when a slight, steady pressure is applied to the touchpad pointer. This symptom is not a hardware problem. No service actions are necessary if the pointer movement stops in a short period of time.
78Chapter 4 Power-On Self-Test (POST) Error Message The POST error message index lists the error message and their possible causes. The most likely cause is listed first. NOTE: Perform the FRU replacement or actions in the sequence shown in FRU/Action column, if the FRU replacement does not solve the problem, put the original part back in the computer. Do not replace a non-defective FRU. This index can also help you determine the next possible FRU to be replaced when servicing a computer. If the symptom is not listed, see “Undetermined Problems” on page 84. The following lists the error messages that the BIOS displays on the screen and the error symptoms classified by function. NOTE: Most of the error messages occur during POST. Some of them display information about a hardware device, e.g., the amount of memory installed. Others may indicate a problem with a device, such as the way it has been configured. NOTE: If the system fails after you make changes in the BIOS Setup Utility menus, reset the computer, enter Setup and install Setup defaults or correct the error.
Chapter 479 Index of Error Messages Error Code List Error CodesError Messages 006 Equipment Configuration Error Causes: 1. CPU BIOS Update Code Mismatch 2. IDE Primary Channel Master Drive Error (THe causes will be shown before “Equipment Configuration Error”) 010 Memory Error at xxxx:xxxx:xxxxh (R:xxxxh, W:xxxxh) 070 Real Time Clock Error 071 CMOS Battery Bad 072 CMOS Checksum Error 110 System disabled. Incorrect password is specified. Battery critical LOW In this situation BIOS will issue 4 short beeps then shut down system, no message will show. Thermal critical High In this situation BIOS will shut down system, not show message. Error Message List Error MessagesFRU/Action in Sequence Failure Fixed Disk Reconnect hard disk drive connector. “Load Default Settings” in BIOS Setup Utility. Hard disk drive System board Stuck Key see “Keyboard or Auxiliary Input Device Check” on page 68. Keyboard error see “Keyboard or Auxiliary Input Device Check” on page 68. Keyboard Controller Failed see “Keyboard or Auxiliary Input Device Check” on page 68. Keyboard locked - Unlock key switch Unlock external keyboard Monitor type does not match CMOS - Run Setup Run “Load Default Settings” in BIOS Setup Utility. Shadow RAM Failed at offset: nnnn BIOS ROM System board System RAM Failed at offset: nnnn DIMM System board Extended RAM Failed at offset: nnnn DIMM System board System battery is dead - Replace and run Setup Replace RTC battery and Run BIOS Setup Utility to reconfigure system time, then reboot system. System CMOS checksum bad - Default configuration usedRTC battery Run BIOS Setup Utility to reconfigure system time, then reboot system. System timer error RTC battery Run BIOS Setup Utility to reconfigure system time, then reboot system. System board
80Chapter 4 Real time clock error RTC battery Run BIOS Setup Utility to reconfigure system time, then reboot system. System board Previous boot incomplete - Default configuration usedRun “Load Default Settings” in BIOS Setup Utility. RTC battery System board Memory size found by POST differed from CMOSRun “Load Default Settings” in BIOS Setup Utility. DIMM System board Diskette drive A error Check the drive is defined with the proper diskette type in BIOS Setup Utility See “External Diskette Drive Check” on page 68. Incorrect Drive A type - run SETUP Check the drive is defined with the proper diskette type in BIOS Setup Utility System cache error - Cache disabled System board CPU ID: System board DMA Test Failed DIMM System board Software NMI Failed DIMM System board Fail-Safe Timer NMI Failed DIMM System board Device Address Conflict Run “Load Default Settings” in BIOS Setup Utility. RTC battery System board Allocation Error for device Run “Load Default Settings” in BIOS Setup Utility. RTC battery System board Failing Bits: nnnn DIMM BIOS ROM System board Fixed Disk n None Invalid System Configuration Data BIOS ROM System board I/O device IRQ conflict Run “Load Default Settings” in BIOS Setup Utility. RTC battery System board Operating system not found Enter Setup and see if fixed disk and drive A: are properly identified. Diskette drive Hard disk drive System board Error Message List Error MessagesFRU/Action in Sequence
Chapter 481 Error Message List No beep Error MessagesFRU/Action in Sequence No beep, power-on indicator turns off and LCD is blank.Power source (battery pack and power adapter). See “Power System Check” on page 69.. Ensure every connector is connected tightly and correctly. Reconnect the DIMM. LED board. System board. No beep, power-on indicator turns on and LCD is blank.Power source (battery pack and power adapter). See “Power System Check” on page 69.. Reconnect the LCD connector Hard disk drive LCD inverter ID LCD cable LCD Inverter LCD System board No beep, power-on indicator turns on and LCD is blank. But you can see POST on an external CRT. Reconnect the LCD connectors. LCD inverter ID LCD cable LCD inverter LCD System board No beep, power-on indicator turns on and a blinking cursor shown on LCD during POST.Ensure every connector is connected tightly and correctly. System board No beep during POST but system runs correctly. Speaker System board
82Chapter 4 Phoenix BIOS Beep Codes CodeBeepsPOST Routine Description 02h Verify Real Mode 03h Disable Non-Maskable Interrupt (NMI) 04h Get CPU type 06h Initialize system hardware 08h Initialize chipset with initial POST values 09h Set IN POST flag 0Ah Initialize CPU registers 0Bh Enable CPU cache 0Ch Initialize caches to initial POST values 0Eh Initialize I/O component 0Fh Initialize the local bus IDE 10h Initialize Power Management 11h Load alternate registers with initial POST values 12h Restore CPU control word during warm boot 13h Initialize PCI Bus Mastering devices 14h Initialize keyboard controller 16h 1-2-2-3 BIOS ROM checksum 17h Initialize cache before memory autosize 18h 8254 timer initialization 1Ah 8237 DMA controller initialization 1Ch Reset Programmable Interrupt Controller 20h 1-3-1-1 Test DRAM refresh 22h 1-3-1-3 Test 8742 Keyboard Controller 24h Set ES segment register to 4 GB 26h Enable A20 line 28h Autosize DRAM 29h Initialize POST Memory Manager 2Ah Clear 215 KB base RAM 2Ch 1-3-4-1 RAM failure on address line xxxx 2Eh 1-3-4-3 RAM failure on data bits xxxx of low byte of memory bus 2Fh Enable cache before system BIOS shadow 30h 1-4-1-1 RAM failure on data bits xxxx of high byte of memory bus 32h Test CPU bus-clock frequency 33h Initialize Phoenix Dispatch Manager 36h Warm start shut down 38h Shadow system BIOS ROM 3Ah Autosize cache 3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 42h Initialize interrupt vectors 45h POST device initialization