    02B0 Diskette drive A/B error Drive A: or B: is present but fails the BIOS POST diskette tests.
    Check the drive is defined with the proper diskette type in BIOS 
    Setup Utility
    Check if the diskette drive is attached correctly.
    See “External Diskette Drive Check” on page 70. 
    02B2 Incorrect Drive A type - run SETUP Type of floppy drive A: not correctly identified in Setup.
    Main board
    02D0 System cache error - Cache disabled RAM cache failed and BIOS disabled the cache. 
    On older boards, check the cache jummpers. You may have to 
    replace the cache.
    Main board
    02F0 CPU ID CPU socket number for Multi-Processor error.
    Main board
    02F4 EISA CMOS not writeable System unable to write to EISA CMOS.
    Main board
    02F5 DMA Test Failed System unable to write to DMA (Direct Memory Access) registers.
    Main board
    02F6 Software NMI Failed System unable to generate software NMI (Non-Maskable Interrupt).
    Main board
    02F7 Fail-Safe Timer NMI Failed Fail-Safe Timer takes too long.
    Main board
    device Address Conflict Specific device has an address conflict.
    Enter the BIOS Setup Utility and verify the parameters (try loading 
    the default settings); then save and restart the computer.
    RTC battery
    Main board
    Failing Bits: nnnn Memery test failed.
    DIMM
    BIOS ROM
    Main board
    Invalid System Configuration Data Error with NVRAM (CMOS) data.
    Enter the BIOS Setup Utility and verify the parameters (try loading 
    the default settings); then save and restart your computer.
    Main board
    I/O device IRQ conflict I/O device has IRQ (Interrupt Request) conflict.
    Enter the BIOS Setup Utility and verify the parameters (try loading 
    the default settings); then save and restart the computer.
    RTC battery
    Main board
    Operating system not found Operating system cannot be found on the boot device.
    Enter the BIOS Setup Utility and verify the parameters (try loading 
    the default settings); then save and restart the computer.
    Recover hard disk.
    Reinstall the operating system.
    Parity Check 1 
    nnnnParity error found on system bus. BIOS attempts to locate the 
    address and display it on the screen. If it cannot locate the address, 
    it displays.
    Parity Check 2 
    nnnnParity error found on I/O bus. BIOS attempts to locate the address 
    and display it on the screen. If it cannot locate the address, it 
    displays .
    Error Message List
    Error MessagesFRU/Action in Sequence 
    						
    							76Chapter 4
    Error Message List
    No beep Error MessagesFRU/Action in Sequence
    No beep, power-on indicator turns off and LCD is 
    blank.Power source (battery pack and power adapter). See “Power 
    System Check” on page 71. 
    Ensure every connector is connected tightly and correctly.
    Reconnect the DIMM.
    LED board.
    Main board.
    No beep, power-on indicator turns on and LCD is 
    blank.Power source (battery pack and power adapter). See “Power 
    System Check” on page 71. 
    Reconnect the LCD connector
    Hard disk drive
    LCD inverter ID
    LCD cable
    LCD Inverter
    LCD
    Main board
    No beep, power-on indicator turns on and LCD is 
    blank.  But you can see POST on an external 
    CRT. Reconnect the LCD connectors.
    LCD inverter ID
    LCD  cable 
    LCD inverter
    LCD
    Main board
    No beep, power-on indicator turns on and a 
    blinking cursor shown on LCD during POST.Ensure every connector is connected tightly and correctly.
    Main board
    No beep during POST but system runs correctly. Speaker
    Main board 
    						
    							Chapter 477
    Index of Symptom-to-FRU Error Message
    LCD-Related Symptoms
    Symptom / ErrorAction in Sequence
    LCD backlight doesnt work
    LCD is too dark
    LCD brightness cannot be adjusted
    LCD contrast cannot be adjustedEnter BIOS Utility to execute “Load Setup Defaults” on Exit screen, 
    then reboot system.
    Reconnect the LCD connectors.
    Keyboard (if contrast and brightness function key doesnt work).
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    Main board
    Unreadable LCD screen 
    Missing pels in characters
    Abnormal screen 
    Wrong color displayedReconnect the LCD connector
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    Main board
    LCD has extra horizontal or vertical lines 
    displayed.LCD inverter ID
    LCD inverter
    LCD cable
    LCD
    Main board
    Indicator-Related Symptoms
    Symptom / ErrorAction in Sequence
    Indicator incorrectly remains off or on, but 
    system runs correctlyReconnect the inverter board
    Inverter board
    Main board
    Power-Related Symptoms
    Symptom / ErrorAction in Sequence
    Power shuts down during operation Power source (battery pack and power adapter). See “Power 
    System Check” on page 71. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    Main board
    The system doesn’t power-on. Power source (battery pack and power adapter). See “Power 
    System Check” on page 71.
    Battery pack
    Power adapter
    Hard drive & battery connection board
    Main board
    The system doesn’t power-off. Power source (battery pack and power adapter). See “Power 
    System Check” on page 71. 
    Hold and press the power switch for more than 4 seconds.  
    Main board
    Battery can’t be charged See “Check the Battery Pack” on page 72. 
    Battery pack
    Main board 
    						
    							78Chapter 4
    PCMCIA-Related Symptoms
    Symptom / ErrorAction in Sequence
    System cannot detect the PC Card (PCMCIA)  PCMCIA slot assembly
    Main board
    PCMCIA slot pin is damaged. PCMCIA slot assembly
    Memory-Related Symptoms
    Symptom / ErrorAction in Sequence
    Memory count (size) appears different from 
    actual size.DIMM
    Main board
    Speaker-Related Symptoms
    Symptom / ErrorAction in Sequence
    In Windows, multimedia programs, no sound 
    comes from the computer. Audio driver
    Speaker
    Main board
    Internal speakers make noise or emit no sound. Speaker
    Main board
    Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence
    The system will not enter hibernation Keyboard (if control is from the keyboard)
    Hard disk drive
    Main board
    The system doesnt enter hibernation mode and 
    four short beeps every minute.Press Fn+F4 and see if the computer enters hibernation mode.
    Touchpad
    Keyboard
    Hard disk connection board
    Hard disk drive
    Main board
    The system doesn’t enter standby mode after 
    closing the LCDLCD cover switch
    Main board
    The system doesnt resume from hibernation 
    mode.Hard disk connection board
    Hard disk drive
    Main board
    The system doesnt resume from standby mode 
    after opening the LCD.LCD cover switch
    Main board
    Battery fuel gauge in Windows doesn’t go higher 
    than 90%. Remove battery pack and let it cool for 2 hours.
    Refresh battery (continue use battery until power off, then charge 
    battery).
    Battery pack
    Main board
    System hangs intermittently. Reconnect hard disk/CD-ROM drives. 
    Hard disk connection board
    Main board 
    						
    							Chapter 479
    NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined 
    Problems” on page 81. Peripheral-Related Symptoms
    Symptom / ErrorAction in Sequence
    System configuration does not match the 
    installed devices. Enter BIOS Setup Utility to execute “Load Setup defaults”, then 
    reboot system.
    Reconnect hard disk/CD-ROM/diskette drives.
    External display does not work correctly. See “System Diagnostic Diskette” on page 48
    See if there is an error beep. If there is an erro beep, then change 
    main board.
    Power off. Then check if RAM CPU BIOS are well-connected.
    Press Fn+F5 three times slowly
    LCD FPC
    LCD inverter
    LCD
    USB does not work correctly See “System Diagnostic Diskette” on page 48
    Main board
    Print problems. Ensure the “Parallel Port” in the “System Devices” of BIOS Setup 
    Utility is set to Enabled.
    Onboard Devices Configuration
    Run printer self-test.
    Printer driver
    Printer cable
    Printer
    Main board
    Keyboard/Touchpad-Related Symptoms
    Symptom / ErrorAction in Sequence
    Keyboard (one or more keys) does not work. Reconnect the keyboard cable.
    Keyboard
    Main board
    Touchpad does not work. Reconnect touchpad cable.
    Touchpad board
    Main board
    Modem-Related Symptoms
    Symptom / ErrorAction in Sequence
    Internal modem does not work correctly.See “System Diagnostic Diskette” on page 48.
    Modem phone port
    modem combo board
    Main board 
    						
    							80Chapter 4
    Intermittent Problems
    Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a 
    hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement 
    should be considered only when a recurring problem exists.
    When analyzing an intermittent problem, do the following:
    1.Run the advanced diagnostic test for the main board in loop mode at least 10 times.
    2.If no error is detected, do not replace any FRU.
    3.If any error is detected, replace the FRU.  Rerun the test to verify that there are no more errors.  
    						
    							Chapter 481
    Undetermined Problems
    The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, 
    whether a short circuit is suspected, or whether the system is inoperative.  
    Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
    NOTE: Verify that all attached devices are supported by the computer.
    NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power 
    System Check” on page 71):
    1.Power-off the computer.
    2.Visually check them for damage. If any problems are found, replace the FRU.
    3.Remove or disconnect all of the following devices:
    !Non-Acer devices
    !Printer, mouse, and other external devices
    !Battery pack
    !Hard disk drive
    !DIMM 
    !CD-ROM/Diskette drive Module
    !PC Cards
    4.Power-on the computer.
    5.Determine if the problem has changed.
    6.If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
    7.If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
    !Main board
    !LCD assembly 
    						
    							82Chapter 4
    Index of AFlash BIOS Error Message
    Error MessageAction in Sequence
    Hardware Error  See “System Diagnostic Diskette” on page 48
    VPD Checksum Error Reboot the system and then restest with this diskette.
    BIOS Update Program Error Turn off the power and restart the system.
    System Error Make sure this AFlash BIOS diskette for this model.
    Without AC adapter make sure to connect AC adapter
    Battery Low make sure to install a highly charged battery, and reboot 
    system. 
    						
    							Chapter 583
    Top View
    Jumper and Connector Locations
    Chapter 5 
    						
    							84Chapter 5
    SW1 Settings (Lid switch)
    SW2 Settings 
    E-JP1 LCD Connector F-JP2 Power Button Board Connetor
    G-JP5 SODIMM Connector H-JP6 Microphone Jack
    I-JP8 Earphones Jack J-JP7, JP9 Speaker Connector
    K-JP10  Main Board to Touch Pad Board FFC 
    connectorL-JP11 Main Board to Touch Pad Board FPC Connector
    M-JP12 JP12 Keyboard Connector
    Setting
    Switch 1 NONE 
    Switch 2 STAND BY
    Switch 3 HIBERNATE
    Switch 4 ON/OFF BUTTON
    SW2Setting
    POWER BUTTON ON:SYSTEM ON
    OFF: SYSTEM OFF 
    						