    							Chapter 473
    Index of Symptom-to-FRU Error Message
    LCD-Related Symptoms
    Symptom / ErrorAction in Sequence
    LCD backlight doesnt work
    LCD is too dark
    LCD brightness cannot be adjusted
    LCD contrast cannot be adjustedEnter BIOS Utility to execute “Load Setup Defaults” on Exit screen, 
    then reboot system.
    Reconnect the LCD connectors.
    Keyboard (if contrast and brightness function key doesnt work).
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    Unreadable LCD screen 
    Missing pels in characters
    Abnormal screen 
    Wrong color displayedReconnect the LCD connector
    LCD inverter ID
    LCD cable
    LCD inverter
    LCD
    System board
    LCD has extra horizontal or vertical lines 
    displayed.LCD inverter ID
    LCD inverter
    LCD cable
    LCD
    System board
    Indicator-Related Symptoms
    Symptom / ErrorAction in Sequence
    Indicator incorrectly remains off or on, but system 
    runs correctlyReconnect the inverter board
    Inverter board
    System board
    Power-Related Symptoms
    Symptom / ErrorAction in Sequence
    Power shuts down during operation Power source (battery pack and power adapter). See “Power 
    System Check” on page 67. 
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board
    The system doesn’t power-on. Power source (battery pack and power adapter). See “Power 
    System Check” on page 67.
    Battery pack
    Power adapter
    Hard drive & battery connection board
    System board
    The system doesn’t power-off. Power source (battery pack and power adapter). See “Power 
    System Check” on page 67. 
    Hold and press the power switch for more than 4 seconds.  
    System board
    Battery can’t be charged See “Check the Battery Pack” on page 68. 
    Battery pack
    System board 
    						
    							74Chapter 4
    PCMCIA-Related Symptoms
    Symptom / ErrorAction in Sequence
    System cannot detect the PC Card (PCMCIA)  PCMCIA slot assembly
    System board
    PCMCIA slot pin is damaged. PCMCIA slot assembly
    Memory-Related Symptoms
    Symptom / ErrorAction in Sequence
    Memory count (size) appears different from 
    actual size.DIMM
    System board
    Speaker-Related Symptoms
    Symptom / ErrorAction in Sequence
    In Windows, multimedia programs, no sound 
    comes from the computer. Audio driver
    Speaker
    System board
    Internal speakers make noise or emit no sound. Speaker
    System board
    Power Management-Related Symptoms
    Symptom / ErrorAction in Sequence
    The system will not enter hibernation Keyboard (if control is from the keyboard)
    Hard disk drive
    System board
    The system doesnt enter hibernation mode and 
    four short beeps every minute.Press Fn+F4 and see if the computer enters hibernation mode.
    Touchpad
    Keyboard
    Hard disk connection board
    Hard disk drive
    System board
    The system doesn’t enter standby mode after 
    closing the LCDLCD cover switch
    System board
    The system doesnt resume from hibernation 
    mode.Hard disk connection board
    Hard disk drive
    System board
    The system doesnt resume from standby mode 
    after opening the LCD.LCD cover switch
    System board
    Battery fuel gauge in Windows doesn’t go higher 
    than 90%. Remove battery pack and let it cool for 2 hours.
    Refresh battery (continue use battery until power off, then charge 
    battery).
    Battery pack
    System board
    System hangs intermittently. See “Thermal & Fan Utility” on page 45. 
    Reconnect hard disk/CD-ROM drives. 
    Hard disk connection board
    System board 
    						
    							Chapter 475
    NOTE: If you cannot find a symptom or an error in this list and the problem remains, see “Undetermined 
    Problems” on page 77. Peripheral-Related Symptoms
    Symptom / ErrorAction in Sequence
    System configuration does not match the 
    installed devices. Enter BIOS Setup Utility to execute “Load Setup defaults”, then 
    reboot system.
    Reconnect hard disk/CD-ROM/diskette drives.
    External display does not work correctly. Press Fn+F5, LCD/CRT/Both display switching
    See “System Diagnostic Diskette” on page 45. 
    System board
    USB does not work correctly See “System Diagnostic Diskette” on page 45
    System board
    Print problems. Ensure the “Parallel Port” in the “System Devices” of BIOS Setup 
    Utility is set to Enabled.
    Onboard Devices Configuration
    Run printer self-test.
    Printer driver
    Printer cable
    Printer
    System Board
    Keyboard/Touchpad-Related Symptoms
    Symptom / ErrorAction in Sequence
    Keyboard (one or more keys) does not work. Reconnect the keyboard cable.
    Keyboard
    System board
    Touchpad does not work. Reconnect touchpad cable.
    Touchpad board
    System board
    Modem-Related Symptoms
    Symptom / ErrorAction in Sequence
    Internal modem does not work correctly. See “System Diagnostic Diskette” on page 45.
    Modem phone port
    modem combo board
    System board 
    						
    							76Chapter 4
    Intermittent Problems
    Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a 
    hardware defect, such as: cosmic radiation, electrostatic discharge, or software errors. FRU replacement 
    should be considered only when a recurring problem exists.
    When analyzing an intermittent problem, do the following:
    1.Run the advanced diagnostic test for the system board in loop mode at least 10 times.
    2.If no error is detected, do not replace any FRU.
    3.If any error is detected, replace the FRU.  Rerun the test to verify that there are no more errors.  
    						
    							Chapter 477
    Undetermined Problems
    The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, 
    whether a short circuit is suspected, or whether the system is inoperative.  
    Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU).
    NOTE: Verify that all attached devices are supported by the computer.
    NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power 
    System Check” on page 67):
    1.Power-off the computer.
    2.Visually check them for damage. If any problems are found, replace the FRU.
    3.Remove or disconnect all of the following devices:
    ❑Non-Acer devices
    ❑Printer, mouse, and other external devices
    ❑Battery pack
    ❑Hard disk drive
    ❑DIMM 
    ❑CD-ROM/Diskette drive Module
    ❑PC Cards
    4.Power-on the computer.
    5.Determine if the problem has changed.
    6.If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.
    7.If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:
    ❑System board
    ❑LCD assembly 
    						
    							78Chapter 4
    Index of AFlash BIOS Error Message
    Error MessageAction in Sequence
    Hardware Error  See “System Diagnostic Diskette” on page 45
    VPD Checksum Error Reboot the system and then restest with this diskette.
    BIOS Update Program Error Turn off the power and restart the system.
    System Error Make sure this AFlash BIOS diskette for this model.
    Without AC adapter make sure to connect AC adapter
    Battery Low make sure to install a highly charged battery, and reboot 
    system. 
    						
    							Chapter 479
    Index of PQA Diagnostic Error Code, Message
    Error CodeMessageAction in Sequence
    16XXX Backup battery error Backup battery
    01XXX CPU or main board error Reload BIOS default setting.
    System board
    02XXX Memory error DIMM
    System board
    03XXX Keyboard error Reset Keyboard
    Keyboard
    System board
    04XXX Video error System board
    05XXX Parallel Port error System board
    06XXX Serial port or main board error System board
    07XXX Diskette drive error Diskette drive
    System board
    08XXX Hard disk error Reload BIOS default setting
    Hard disk
    System board
    09XXX CD-ROM error Reset CD-ROM cable
    CD-ROM drive
    System board
    10XXX Co-processor error System board
    11XXX Pointing device error Reset Keyboard
    Keyboard
    System board
    12XXX Cache test error System board 
    						
    							Chapter 581
    To p  V i e w
    PCB 01200-S
    SW2 POWER.-BTN
    JP2 LCD
    SW2 Power On/Off button JP1 It is software debug only, normally 
    shiping on this connector
    JP2 LCD connector JP7 FDD connector
    SW1 LID switch JP6 Internal keyboard connector
    JP3 System Board connector JP4 Switch board connector
    PIN NOSignalPIN NOSignal
    1. ON/OFF BTN# 2. ON/OFF BTN#
    3. GND 4. GND
    PIN NOSignalPIN NOSignal
    1. +5VALW 2. GND
    3. +5VALW 4. GND
    5. NC 6. NC
    7. 20 INVT_PWN 8. DISPOFF#
    9. +5VALW 10. LCDDVDD
    Jumper and Connector Locations
    Chapter 5 
    						
    							82Chapter 5
    SW1 LID-SW
    JP3 HEADERX.PRT
    JP1 DEBUG-9.PRT
    11. +5VALW 12. LCDVDD
    13. +3VS 14. LCDDVGA
    15. +3VS 16. LCDDVGA
    17. GND 18. GND
    19. NC 20. L LCD0
    21. GND 22. L LCD1
    23. PID0 24. GND
    25. PID1 26. L LCD2
    27. PID2 28. L LCD3
    29. PID3 30. GDN
    31. ENVDD 32. L LCD4
    33. DISPOFF# 34. L LCD5
    35. L LCD15 36. GDN
    37. L LCD14 38. L LCD6
    39. GND 40. L LCD7
    41. L LCD13 42. GDN
    43. L LCD12 44. L LCD8
    45. GND 46. L LCD9
    47. L LCD11 48. GDN
    49. L LCD10 50. NC
    PIN NOSignalPIN NOSignal
    1. GND 2. GND
    3. LID_SW# 4. LID_SW#
    PIN NOSignalPIN NOSignal
    1. +5VALW 2. ACIN
    3. HDD_LED# 4. CD_FDD_LED#
    5. CAPS_LED# 6. ARROW_LED#
    7. NUM_LED# 8. GND
    9. +5VS 10. +3VS
    PIN NOSignalPIN NOSignal
    1. +5V 2. GND
    3. RXD0F# 4. TXD0F#
    5. DSR0F 6. RTS0F
    7. CTS0F 8. DTR0F
    9. RI0F 10. D0F
    PIN NOSignalPIN NOSignal 
    						
    All Acer manuals Comments (0)