Home > Accusplit > Stopwatch > Accusplit Stopwatch AX602FY User Manual

Accusplit Stopwatch AX602FY User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Accusplit Stopwatch AX602FY User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 150 Accusplit manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							b-1
    ACCUSPLIT, Inc.
    6120 Stoneridge Mall Rd., Suite 210 Pleasanton, CA 94588 USA
    800-965-2008  •  925-226-0888  •  FAX 925-463-0147
    www.ACCUSPLIT.com  •  [email protected]
    980-312
    ACCUSPLIT®
    E X CLUSIVE
    AX602FY
    STOPWATCH
    OPERATING
    INSTRUCTIONS
    2-3
    ACCUSPLIT® AX602FY 
    DIGITAL 100 MEMORY STOPWATCH 
    WITH SPLIT AND LAP TIME MEASUREMENT AND 
    STROKE/FREQUENCY MEASURING FUNCTIONS
    FEATURESThe Quartz Stopwatch is a digital 
    stopwatch featuring memory and 
    stroke/frequency measuring func-
    tions. In addition, the stopwatch 
    is water resistant. Therefore, it is 
    suitable for aquatic sports or use 
    in rainy weather.
    •  STOPWATCH
      The stopwatch can measure up  
      to 10 hours in 1/100 seconds.
    •   SPLIT TIME/LAP TIME 
     MEASUREMENT
      Up to 100 split times and lap 
      times can be measured.
    2
    •   LARGE-SIZED THREE-ROW DISPLAY PANEL
      Total elapsed time, split time and lap time are displayed at the same 
      time in separate rows, and they can be measured successively 
      without releasing split or lap time measurement.
    •   MEMORY FUNCTION
      Up to 100 measurements can be stored in memory, and they can be 
      recalled after the measurement is over.
    •   TIME/CALENDAR DISPLAY
      Year, month, date, hour, minutes, and seconds can be displayed while 
      the stopwatch is not in use.
    •   BATTERY LIFE INDICATOR
      Lithium battery CR2032 or equivalent is used.
    •   ACCUSPLIT “X” CASE
      Exclusive professional case with no-fail buttons.
    3 
    						
    							4-5
    There are four buttons as 
    indicated in the illustration.
    TIME/CALENDARdisplay
    STOPWATCHdisplay
    4
    STROKE/FREQUENCY MEASURING MODE
    STROKE/FREQUENCYMEASURING display
    A
    C
    B
    D
    5
    TIME/CALENDAR SETTING
    1. Press “D” to show the time/calendar display. The time/calendar display 
        mark will appear.
    2. S1 – Press and hold “B” for 2 seconds until seconds display begins \
     ashing. TIME/CALENDAR display mark
    A
    C
    B
    D
    Year
    Month and date
    Seconds
    Minutes
    Hour
    ACCUSPLIT products use a common setting procedure known as S1-S2-S3-S4.
    S1  (2 sec) - Enter set function OR 
    S1  (4 sec) - Enter set function & 
      clear the current settings
    S2 – Select  eld to be set 
      (selected  eld will  ash)
    S3 – Set  eld to desired settings
    S4 – Exit setting function
    6-7
    6
    7
    STOPWATCH
    Press “D” in the TIME/CALENDAR display to show the STOPWATCH display. 
    The STOPWATCH display mark will appear.
    The STOPWATCH can measure up to 10 hours in hours, minutes, seconds and 
    1/100 seconds.
      •  Before using the stopwatch be sure to reset the digits to “0:00:00.00\
    ”.
        When the stopwatch is stopped, press ”B” to reset.
        When the stopwatch is counting, press “A” to stop the measurement \
        and then press “B”.
    A
    C
    B
    D
    STOPWATCH display mark Split time
    Lap time
    Total time (accumulated 
    elapsed time)
    Split/lap number
    3. S2 – Press “B” repeatedly to select the digits ( ashing) to be adjusted. 
        With each press of “B,” the digits to be adjusted change over \
    in the 
      following order. 
    4. 
    S3 – Press “A” to set the  ashing digits or reset the seconds to “00”.
      •  The digits move quickly if “A” is kept pressed.
      •  When the seconds digits count any number from ”30” to “59” a\
    nd “A” is 
        pressed, one minute is added and the second digits are reset to “00”\
    .
    5.  S4  – After all the adjustments are completed, press “A” repeatedly\
     until watch 
      exits set mode and returns to the TIME/CALENDAR  display.
    Notes:
    1. Hour digits are displayed in the 24-hour indication.
    2. Year digits can be set from 1988 to 2027. The calendar adjusts automatica\
    lly for 
    odd and even months including February of leap years.
     seconds  minutes  hour  year  month  date
        Note:  The watch exits set mode automatically after setting date. 
    						
    							8-9
    AAB
      •  “Split time” refers to an elapsed time required to cover a distanc\
    e from 
        the start to a given point.
      •  “Lap time” refers to an elapsed time required to cover a given sec\
    tion 
        of the whole distance.
    Lap time
    Split time
    Start
    1. STANDARD MEASUREMENT
        Hour  Seconds
                Minutes        1/100 seconds
    START
    STOPRESET
    8
    2. ACCUMULATED ELAPSED TIME MEASUREMENT
    9
    START STOPRESTART
    RESET STOP
    Restart and stop 
    of the stopwatch  can be repeated by pressing “A”.
    BA
    AA
    10-11
    10
    3. SPLIT TIME/LAP TIME MEASUREMENT
    Note:  When the number of stored measurements 
          exceeds 90,  ashing “FULL” appears, and when 
          it exceeds 100, a warning sound starts beeping.
    B
    A B
    AB
    BSTART SPLIT-LAP 1 SPLIT-LAP 2
    RESET STOP
    SPLIT-LAP 8
    The split/lap time can 
    be measured repeated  by pressing “B”.Split/lap number Split time
    Lap time
    Accumulated 
    elapsed time
    Finish time
    11
    The stopwatch can store up to 100 split times, 100 lap times and total e\
    lapsed 
    time. They are automatically entered into the memory.
      •  With each press of “C”, the time stored is recalled. The time can be 
        recalled successively by keeping the button pressed.
      •  To stop the recall of the stored data, press “A”, “B”, or “D”. The 
        measurements when the stopwatch was stopped will be shown. 
        Then, press “B” to reset the digits to “00”.
    4. HOW TO USE THE MEMORY FUNCTION
    B
    CC
    A
    C
    C
    “RECALL” more
    Finish time
    Reset to “00” 
    						
    							12-13
    12
      •  The time stored in the memory can be recalled even while the stopwatch 
      is measuring.
    Notes:
    1. Even if the digits are reset to “00”, stored times are not eras\
    ed and can be 
      recalled by pressing “C” unless new measurement is started.
    2. If the stopwatch is left untouched with the recalled times shown, the\
     display 
      will automatically return the STOPWATCH display in 1 to 20 minutes.
      •  To measure the lap time and split time while the stored data are being    
        recalled operate the buttons as follows.
        Press “B” to measure new lap time and split time.
        Press “A” to stop the measurement.
        Press “D” to return to the measurement mode.With each press of “C”
    When the stopwatch is stopped Split time and lap time are recalled starting with the  rst ones.
    When the stopwatch is measuring The times are recalled starting with  the last ones.BA
    13
    Press “D” to show the STROKE/FREQUENCY MEASURING display.
    Start the measurement by pressing “A” and stop the measurement by \
    pressing 
    “A” after the third stroke was made. The number of strokes per min\
    ute will be 
    displayed. STOKE/FREQUENCY MEASURING
    B Start
    MeasuringStop Reset
    A AB
    Start Stop
    STROKE/
    FREQUENCY 
    MEASURING  mode The number 
    of strokes 
    per minute  (23.2)
    14-15
    14
    Notes:
    1. During 1 second after the measurement has been started by pressing “\
    A”, 
       ashing “180.0” is displayed. If the measurement is stopped by pres\
    sing 
      “A”  during this period, “Err” will appear. If the measurement is not stopped 
      by pressing “A” after more than 18 seconds have elapsed, “Err”\
     will
      automatically appear. Therefore, note that measurable number of strokes 
      per minute is between 10 and 180.
    2. If “B” is pressed while the measurement is stopped or “Err”\
     is shown, the 
      digits will be reset “0.0”. Even if the digits are not reset to “0.0” with the 
      measurement stopped or “Err” shown on the display, the measurement 
      can be started by pressing “A”.
    Error
    15
    NO-PROOF-OF-PURCHASE  LIMITED WARRANTY See label on back of unit for details, or check 
    http://support.ACCUSPLIT.com
    REGISTER NOW Please return 
    your AX602FY Registration to 
    the Repair Center address in the 
    warranty, and we will let you 
    know about future products. Email (preferred)
    User 
    						
    All Accusplit manuals Comments (0)

    Related Manuals for Accusplit Stopwatch AX602FY User Manual