Accusplit Stopwatch AX602FY User Manual
Have a look at the manual Accusplit Stopwatch AX602FY User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 150 Accusplit manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
b-1 ACCUSPLIT, Inc. 6120 Stoneridge Mall Rd., Suite 210 Pleasanton, CA 94588 USA 800-965-2008 • 925-226-0888 • FAX 925-463-0147 www.ACCUSPLIT.com • [email protected] 980-312 ACCUSPLIT® E X CLUSIVE AX602FY STOPWATCH OPERATING INSTRUCTIONS 2-3 ACCUSPLIT® AX602FY DIGITAL 100 MEMORY STOPWATCH WITH SPLIT AND LAP TIME MEASUREMENT AND STROKE/FREQUENCY MEASURING FUNCTIONS FEATURESThe Quartz Stopwatch is a digital stopwatch featuring memory and stroke/frequency measuring func- tions. In addition, the stopwatch is water resistant. Therefore, it is suitable for aquatic sports or use in rainy weather. • STOPWATCH The stopwatch can measure up to 10 hours in 1/100 seconds. • SPLIT TIME/LAP TIME MEASUREMENT Up to 100 split times and lap times can be measured. 2 • LARGE-SIZED THREE-ROW DISPLAY PANEL Total elapsed time, split time and lap time are displayed at the same time in separate rows, and they can be measured successively without releasing split or lap time measurement. • MEMORY FUNCTION Up to 100 measurements can be stored in memory, and they can be recalled after the measurement is over. • TIME/CALENDAR DISPLAY Year, month, date, hour, minutes, and seconds can be displayed while the stopwatch is not in use. • BATTERY LIFE INDICATOR Lithium battery CR2032 or equivalent is used. • ACCUSPLIT “X” CASE Exclusive professional case with no-fail buttons. 3
4-5 There are four buttons as indicated in the illustration. TIME/CALENDARdisplay STOPWATCHdisplay 4 STROKE/FREQUENCY MEASURING MODE STROKE/FREQUENCYMEASURING display A C B D 5 TIME/CALENDAR SETTING 1. Press “D” to show the time/calendar display. The time/calendar display mark will appear. 2. S1 – Press and hold “B” for 2 seconds until seconds display begins \ ashing. TIME/CALENDAR display mark A C B D Year Month and date Seconds Minutes Hour ACCUSPLIT products use a common setting procedure known as S1-S2-S3-S4. S1 (2 sec) - Enter set function OR S1 (4 sec) - Enter set function & clear the current settings S2 – Select eld to be set (selected eld will ash) S3 – Set eld to desired settings S4 – Exit setting function 6-7 6 7 STOPWATCH Press “D” in the TIME/CALENDAR display to show the STOPWATCH display. The STOPWATCH display mark will appear. The STOPWATCH can measure up to 10 hours in hours, minutes, seconds and 1/100 seconds. • Before using the stopwatch be sure to reset the digits to “0:00:00.00\ ”. When the stopwatch is stopped, press ”B” to reset. When the stopwatch is counting, press “A” to stop the measurement \ and then press “B”. A C B D STOPWATCH display mark Split time Lap time Total time (accumulated elapsed time) Split/lap number 3. S2 – Press “B” repeatedly to select the digits ( ashing) to be adjusted. With each press of “B,” the digits to be adjusted change over \ in the following order. 4. S3 – Press “A” to set the ashing digits or reset the seconds to “00”. • The digits move quickly if “A” is kept pressed. • When the seconds digits count any number from ”30” to “59” a\ nd “A” is pressed, one minute is added and the second digits are reset to “00”\ . 5. S4 – After all the adjustments are completed, press “A” repeatedly\ until watch exits set mode and returns to the TIME/CALENDAR display. Notes: 1. Hour digits are displayed in the 24-hour indication. 2. Year digits can be set from 1988 to 2027. The calendar adjusts automatica\ lly for odd and even months including February of leap years. seconds minutes hour year month date Note: The watch exits set mode automatically after setting date.
8-9 AAB • “Split time” refers to an elapsed time required to cover a distanc\ e from the start to a given point. • “Lap time” refers to an elapsed time required to cover a given sec\ tion of the whole distance. Lap time Split time Start 1. STANDARD MEASUREMENT Hour Seconds Minutes 1/100 seconds START STOPRESET 8 2. ACCUMULATED ELAPSED TIME MEASUREMENT 9 START STOPRESTART RESET STOP Restart and stop of the stopwatch can be repeated by pressing “A”. BA AA 10-11 10 3. SPLIT TIME/LAP TIME MEASUREMENT Note: When the number of stored measurements exceeds 90, ashing “FULL” appears, and when it exceeds 100, a warning sound starts beeping. B A B AB BSTART SPLIT-LAP 1 SPLIT-LAP 2 RESET STOP SPLIT-LAP 8 The split/lap time can be measured repeated by pressing “B”.Split/lap number Split time Lap time Accumulated elapsed time Finish time 11 The stopwatch can store up to 100 split times, 100 lap times and total e\ lapsed time. They are automatically entered into the memory. • With each press of “C”, the time stored is recalled. The time can be recalled successively by keeping the button pressed. • To stop the recall of the stored data, press “A”, “B”, or “D”. The measurements when the stopwatch was stopped will be shown. Then, press “B” to reset the digits to “00”. 4. HOW TO USE THE MEMORY FUNCTION B CC A C C “RECALL” more Finish time Reset to “00”
12-13 12 • The time stored in the memory can be recalled even while the stopwatch is measuring. Notes: 1. Even if the digits are reset to “00”, stored times are not eras\ ed and can be recalled by pressing “C” unless new measurement is started. 2. If the stopwatch is left untouched with the recalled times shown, the\ display will automatically return the STOPWATCH display in 1 to 20 minutes. • To measure the lap time and split time while the stored data are being recalled operate the buttons as follows. Press “B” to measure new lap time and split time. Press “A” to stop the measurement. Press “D” to return to the measurement mode.With each press of “C” When the stopwatch is stopped Split time and lap time are recalled starting with the rst ones. When the stopwatch is measuring The times are recalled starting with the last ones.BA 13 Press “D” to show the STROKE/FREQUENCY MEASURING display. Start the measurement by pressing “A” and stop the measurement by \ pressing “A” after the third stroke was made. The number of strokes per min\ ute will be displayed. STOKE/FREQUENCY MEASURING B Start MeasuringStop Reset A AB Start Stop STROKE/ FREQUENCY MEASURING mode The number of strokes per minute (23.2) 14-15 14 Notes: 1. During 1 second after the measurement has been started by pressing “\ A”, ashing “180.0” is displayed. If the measurement is stopped by pres\ sing “A” during this period, “Err” will appear. If the measurement is not stopped by pressing “A” after more than 18 seconds have elapsed, “Err”\ will automatically appear. Therefore, note that measurable number of strokes per minute is between 10 and 180. 2. If “B” is pressed while the measurement is stopped or “Err”\ is shown, the digits will be reset “0.0”. Even if the digits are not reset to “0.0” with the measurement stopped or “Err” shown on the display, the measurement can be started by pressing “A”. Error 15 NO-PROOF-OF-PURCHASE LIMITED WARRANTY See label on back of unit for details, or check http://support.ACCUSPLIT.com REGISTER NOW Please return your AX602FY Registration to the Repair Center address in the warranty, and we will let you know about future products. Email (preferred) User