Accusplit Stopwatch AE602M100 LONG User Manual
Have a look at the manual Accusplit Stopwatch AE602M100 LONG User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 150 Accusplit manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Press [RECALL] again to view the average lap time. Press [RECALL] continually to review all the stored split/lap times. The sequence starts from the last record to the first record when the stopwatch is running and vice versa when the stopwatch has been stopped. [RECALL] [RECALL] [RECALL] 0: 00 05 120: 03 16 03 RECALL AVG LAP RU N{005} 0: 00 14 910: 00 02 050: 03 28 94 SPLIT LAP RU N{005}RECALL 0: 00 12 860: 00 01 600: 03 33 64 SPLIT LAP RU N{004}RECALL 0: 00 11 260: 00 01 780: 03 40 15 SPLIT LAP RU N{003}RECALL 0: 00 09 480: 00 01 850: 03 45 34 SPLIT LAP RU N{002}RECALL 9
[RECALL] After recalling the first record, press [RECALL] once more to exit from Recall mode and go back to chronograph mode. The RECALL icon will be OFF. [RECALL] During memory recall, you can press either [START], [STOP] or [LAP/SPLIT] to exit from chrono recall mode and jump to the chrono start/stop or lap state respectively. Data Mode (AE760M & AE790M Model only)Press [MODE] until you enter DATA mode The mode message DATA will be shown for one to two seconds before the number of free memories is to be shown. You can press [START] to scroll through all segments. The current segment will come first. 0: 00 07 630: 00 07 630: 03 48 01 SPLIT LAP RU N{001}RECALL 0: 03 50 110: 00 42 600: 03 50 11 SPLIT LAP RU N{005} FREE 95 LAP 2 0 0 12 - 1 9A 10: 15 30 {008}RECALL {002}SEG 10
The header consisting of the date/time stamp will be shown. The number of laps in the segment will appear in the upper left while the segment number is displayed in the middle left. If the segment shown is not your desired segment, press [START] to reach the desired segment. The current segment will be accessed first, then it will cycle back to the 1st, then 2nd and so on. When you have found the segment you want, you can press [RECALL] button consecutively to read the lap records from the first to the last lap. As you continue to press [RECALL] during the display of the last lap, you can advance to the next segment by pressing [START], The front page of the segment will be shown. Say the next segment is SEG 1. How to delete individual memory segments:- Search the desired segment first as described above. During the display of the segment front page, press [RESET] for 2 seconds to activate Delete One function. DELETE ONE will be shown in blinking and beep sound will be generated. A ready period of 2 seconds will be counted. At the end of the ready period, all the lap records of the corresponding segment will be erased. And a long beep sound will be heard. Then the display will show the next segment. If you dont want to delete the records, you can press any key to exit from delete ready state before the end of the ready period and resume the display of the segment front page. 0: 01 00 550: 00 12 860: 01 00 55 SPLIT LAP RU N{001}RECALL {002}SEG 2 0 0 12 - 1 8A 10: 00 15 {012}RECALL {001}SEG dELETE OnE 11
How to delete all memory segments:- Instead of deleting one segment, you can also delete all memory segments. When you enter the Data mode, you see the screen FREE XXX LAP. Press and hold the [RESET] for 3 seconds. You will hear Beep, beep, beep for 3 seconds, then a long Beep. At this point all data in the memory will be deleted and DELETE ALL will show on the display. If you dont want to delete the records, you can press any key to exit DELETE ALL state before the end of the ready period and resume the display of the segment front page. Timer ModePress [MODE] until you enter the Timer mode. 3 count-down operation modes are available on this stopwatch: - Count down repeat ( CR ) - Count down stop ( CS ) - Count down, then count up ( CU ) The timer is set at the factory to the count-down repeat (CR) mode. At entering timer mode, the mode message TIMER will be shown for a second before the timer counting is to be displayed. The upper line shows the programmable timer value (initially set at 0:00:00:0) while the middle line displays the current timer counting. Time of Day clock display is at the lower line of the display. CR indicates the current timer operating mode while the timer cycle counter is located at the upper left of the display. Before starting the timer, enter a countdown time first. Then press [START] to start timer running. When the timer counts down to zero, a 3 second beep ... beep sound will be generated for a timer setting within one minute; 15 second beep ... beep sound for 1 minute to 10 minutes setting and 30 second beep ... beep sound for over 10 minutes. Pressing any key will stop the beep sound. Under CR operation mode, the timer value will be reloaded and count down will star t again. The timer cycle counter will be increased by one and updated on the display. dELETE ALL 0: 00 00 0CR 0: 00 00 0A 12 : 58 20 {000} 12
Under CS operation mode, the timer, after counting down to 0:0000, will stay at 0:00000 until you press [RESET] to reload the timer value. Under CU operation mode, the timer, after counting down to 0:00000, will count up and stop at 19:59599. How to set the timer Press and hold [RECALL] for 2 seconds to activate timer setting. Timer setting starts with second digits, which are shown blinking. You can press [START] to advance the flashing digits. Or you can press [RESET] to select other digits. The setting is in sequence of second, minute, hour and timer operating mode (CR, CS and CU). NOTE: You can only set Hour, Minute and Seconds. The 1/10 second cannot be set. Press and hold [RECALL] for 2 seconds. Timer setting starts with second digits. Press [RESET] to move to minute digits. Press [RESET] further to go to hour digits. Hour digits can be adjusted from 0 to 19. Press [RESET] again to adjust the operating mode. Press [START] to switch the operating modes among CR, CS and CU. At the end of setting, press [RECALL] or [MODE] to leave setting mode. 0: 00 00 0CR 0: 00 00 0A 12 : 58 55 {000} 0: 00 00 0CR 0: 00 00 0A 12 : 58 57 {000} 0: 00 00 0CR 0: 00 00 0A 12 : 59 02 {000} 0: 00 00 0CR 0: 00 00 0A 12 : 59 11 {000} 13
Pacer ModePress [MODE] until you enter the Pacer mode. In the Pacer mode, you can set the standard pacer speed from 5 to 240 beats per minute in the following values: 5, 10, 20, 30, 40, 50, 60, 80, 100, 120, 150, 180, 200, 240 In Pacer mode, the display will be:- The digits are flashing to indicate that the pace count is ready for setting. Press [RESET] to select the pace count. Once the desired pace count is selected, press [START] to confirm the setting and start the pace count. The display will show the elapsed time on the upper line, the pace count number on the middle and the pace count value on the lower display. Press [STOP] to stop the pace count. The STOP indicator is ON to show the status and the display freezes. To restar t the pace count, press [START] again. Or press [RESET] to reset the time elapsed and the pace count number as follows:- Stroke MeasurementPress [MODE] until you enter the Stroke Measurement mode. The display will be as follows. 0: 00 51 85C - 00 51P - 60 0: 00 00 00C - 00 00P - 60 PACER P - 5 STROkE 0. 0 14
In the Stroke Measurement mode, the duration of 3 strokes is taken and the stroke frequency (counts per minute) is calculated. As the stroke frequency falls out of the range of 10 - 180, Err will appear to show the error condition. Press [START] to start the measurement. During the 1st second, 180.0 will be shown and flashing as below. At the end of the first second, the display will become steady. If measurement is stopped in the first second (stroke frequency > 180), error signal Err will be shown. After the first second has elapsed, the instantaneous measurement reading will be shown. When you press [STOP], the display will show the steady stroke measurement reading. If the measurement lasts for more than 18 seconds (stroke frequency < 10), an error signal Err will be displayed. When the measurement is stopped, press [RESET] to reset the displayed reading to 0.0. Speed Mode (AE760M100 & AE790M500 Model only)Press [MODE] until you enter the Speed mode. The display will be as follows. (Note that the default setting is KM. Hence KM icon will be ON.) The upper line shows the distance or speed. The lap time is in the middle line, while the total time is displayed on the lower line. In the Speed mode, you can record a number of lap times and speeds for covering the distance you program into the chronograph.. Before starting to use the Speed mode, you need to enter the distance as explained below. Otherwise, the speed measurement wont work. STROkE 180. 0 0. 0 0 0 0: 00 00 000: 00 00 00LAP STOP {000}DIST KM 15
Distance SettingPress [RECALL] for 2 seconds to enter setting mode, the unit icon flashes. Press [START] to toggle between KM and MILE. To select the following digits, press [RESET]. The far right digit will blink and you can set the distance from the least significant digit to the most significant digit. The distance can be set in the range 0.000 to 1999.999 km (or ML). Press [RECALL] OR [MODE] to exit from the setting mode. As an example, the distance is set at 400m. Speed Mode RunningPress [START] to start the Speed timer. The STOP indicator is OFF. The maximum time can be up to 19 hr. 59 min. 59.99 sec. While the timer is running, press [LAP/SPLIT] to record the lap time and the corresponding speed (in km/hr or mph) will be displayed on the upper line. The lap counter (shown on the upper left corner) will advance by one. 0 0 0. 0 0 0 0: 00 00 000: 00 00 00LAP STOP {000}DIST KM 0. 4 0 0 0: 00 00 000: 00 00 00LAP STOP {000}DIST KM 2 5. 7 6 0 0: 01 05 350: 01 05 35LAP RU N {001}DIST KM 0. 0 0 0 0: 00 00 000: 00 05 35LAP RU N {000}DIST KM 16
Press [LAP/SPLIT] to record more lap times and show different speeds. Note that as the speed exceeds the value 1999.999 km/hr or 1999.999 mph, Err will be shown and no storage will be made for that record. [LAP/SPLIT] [LAP/SPLIT] To stop the speed measurement, press [STOP] to stop the timer. Before star ting again, you can reset the timer by pressing [RESET]. Note: When you reset the Speed timer, the speed measurement starts again from a reset state, and all speed records in memory will be cleared (provided that the storage is not under segmented run memory mode). The Recall function is similar to chronograph recall. If segmented run memory is selected, the DATA mode can be accessed and records storing both the speed and elapsed time can be retrieved. 2 2. 0 6 0 0: 01 05 250: 02 01 15LAP RU N {002}DIST KM 2 5. 7 3 0 0: 00 55 950: 02 57 10LAP RU N {003}DIST KM 2 5. 7 3 0 0: 00 59 130: 03 48 23LAP STOP {003}DIST KM 0. 4 0 0 0: 00 00 000: 00 00 00LAP STOP {000}DIST KM 17
Lap Time & Speed RecallSimilar to the Chrono Recall mode, during speed measurement or Stop state, you can press [RECALL] to recall the speed/lap memories. The Mode message will be shown for one to two seconds as the Mode message display is displayed. The Speed and Lap time will be displayed on the upper and the middle lines. The lower line shows the current time counting. During Data recall, the fastest speed will be reviewed first, then the slowest speed and average speed. Further presses of [RECALL] will retrieve the memories in ascending order or reverse order depending on whether the speed measurement is stopped or under operation respectively. During Recall, the Recall indicator is ON. (Note: Speed mode and Chrono mode will not run simultaneously. When Chrono mode is active, Speed mode should be in reset state and vice versa.) RECALL 18