Home > Accusplit > Stopwatch > Accusplit Stopwatch A940MXTBL User Manual

Accusplit Stopwatch A940MXTBL User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Accusplit Stopwatch A940MXTBL User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 150 Accusplit manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    980-301
    ACCUSPLIT A940MXT 
    Wrist-Worn Stopwatch with Split Memory
    Operating Instructions
    Congratulations on your purchase of an A940MXT stopwatch  
    for the wrist!  You’re about to enjoy the convenience of having  
    professional timing right at your fingertips when you need it,  
    plus a regular wristwatch whenever you don’t.   
    SETUP
    Most watches ship with a battery inter-
    rupt in place to save battery life.  Turn the 
    watch over and use a quarter or nickle 
    to twist open the battery compartment 
    hatch.  Remove clear plastic strip from 
    underneath the battery.  Replace the bat-
    tery, taking care to ensure that the posi-
    tive (+) terminal is facing up.  Replace the 
    battery compartment hatch and tighten 
    with the coin, making sure that the small 
    arrow points to the dot at the top of the 
    watch case when you are finished.  Peel 
    the simulated display sticker off the 
    watch face.  
    Your new watch has four modes of 
    operation: 1/100th second Memory 
    Stopwatch with Turbo features, a Dual 
    Set-Point Timer, plus two Time-of-Day/
    Date/Alarm modes. When the battery is 
    enabled, your watch will come to life in 
    stopwatch mode. Press the ( button to 
    cycle between the modes.  
    Your watch also has an Electro-Lumines-
    cent (EL) backlight.  Press the EL button 
    to activate the backlight.
    STOPWATCH MODE
    The watch features a professional timing 
    circuit with powerful stopwatch features.  
    This is how the display looks when in 
    stopwatch mode.
    0:32:29.38
    0:05:03.1 1
    ACCUSPLIT
    ∞  S1/S4                                                               S2             AOS
    L
    E L
    S3M
    940MXTURBO
    4SPLIT
    Master Reset
    Its a good idea to reset the stopwatch 
    each time before use.  Push S2 for 2 sec-
    onds to Reset**
    Event Timing
    Event timing is the simplest form of tim-
    ing. It is good when you want to mea-
    sure the total time from the start to the 
    finish of a particular event.
    S2 – Start
    S2 – Stop (Display shows “SPLIT”)
    S2 (2sec) – Reset**
    Dual Split Memory with Split Counter 
    When timing an activity with pauses  
    or repeated events, you will need to  
    use split timing with memories. 
    S2 – Start (Shows Running DUAL Time)
    S2 – Split* (Top shows CUM 1, Bottom  
      shows LAP 1)
    S2 – Split* (shows CUM 2, Bottom shows  
      LAP 2) 
    S2 – Split* (Top shows CUM 3, Bottom  
      shows LAP 3)
    S2 – Split* (Top shows CUM 4, Bottom  
      shows LAP 4)
    S2 (2sec) – Reset**
    *Split Counter always shows Current Split Note: You can always press S1/S4 to return  to Running Time.
    Memory Review (before Resetting)
    M – Review* (Bottom shows AVE LAP  
      Split, Top shows TOTAL ELAPSED TIME)
    M – Review (Shows last DUAL Split)
    M – Review (Shows next DUAL Split, in  
      reverse order)
    *Reviews at any time in reverse numerical order. Hold down for Rapid Review.
    STOPWATCH AND SPEED/RATE
    The advanced “Turbo” functions on 
    the watch calculate speed or rate once 
    distance has been input into the watch 
    (recall that Rate = Units/Time). 
    0 00 0.000
    ACCUSPLIT
    ∞  S1/S4                                                               S2             AOS
    L
    E L
    S3M
    940MXTURBO
    p-hr
    DIST
    Speed/Rate Function Setting
    S1(2sec) - Enter Turbo (Speed/Rate) Set  
      Function 
    S1(4sec) – Enter set function and Reset  
      Turbo fields to zero (as for DUAL 
     
      SPLIT timing)
    S2 – Select field to be Set (field will  
      flash)
    S3 – Set field to Desired Setting
    S4 – Exit Setting Function
    When a Distance or Sample Count Is set 
    In Turbo Set Up mode, “SPD” (Speed) 
    indicator will be illuninated at bottom of 
    display.  The number you enter should 
    correspond to the Distance or Sample 
    Count you want to use for the Speed 
    or Rate Computation. “P-HR” in display 
    means watch is set to compute “per 
    Hour” rate, and “P-Mn” means watch is 
    set to compute a “per Minute” rate. 
    If you want the watch to compute in “per 
    Sec” rate, divide the Distance or Sample 
    Count (Strokes, Strides, Units, etc.) by 
    60, then enter it. 
    For example, let’s say that you are at a 
    race track with a course that is one mile 
    long. If you set the Distance to 1.00 and 
    the rate to “P-HR,” and then time several 
    laps, the Average Speed recorded by the 
    watch will be in miles per hour. 
    Speed/Rate Function Operation 
    S2 – Start (Shows Running LAP Time)
    S2 – Split* (Top and Bottom show  
      SPEED/RATE 1/LAP 1)
    S2 – Split* (Top and Bottom show  
      SPEED/RATE 2/LAP 2)
    S2 – Split* (Top and Bottom show  
      SPEED/RATE 3/LAP 3)
    S2 (2sec) – Reset LAP and SPEED/RATE  
      to zero**
    *For only chance to view Total Average Speed/Rate, push M.
    Memory Review (before Resetting)
    M – Review* (Bottom shows AVE  
      TOTAL SPEED/RATE, Top shows TOTAL 
     
      ELAPSED TIME)
    M – Review* (Bottom shows AVE LAP  
      Split, Top shows TOTAL ELAPSED TIME)
    M – Review (Shows last SPEED/RATE  
      and LAP Split)
    M – Review (Shows next SPEED/RATE  
      and LAP Split, in reverse order)
    *Reviews at any time in reverse numerical order. Hold down for Rapid Review.
    **Reset before 30 hrs. (end of range) and rollover.
    ACCUSPLIT, Inc.  •  6120 Stoneridge Mall Rd., Suite 210  •  Pleasanton, CA 94588 USA
    800-965-2008  •  925-226-0888  •  FAX 925-463-0147  •  www.ACCUSPLIT.com  •  [email protected]
    0:32:29.38
    0:05:03.1 1
    ACCUSPLIT
    ∞  S1/S4                                                               S2             AOS
    L
    E L
    S3M
    925MXTURBO
    4
    SPLIT
    S1/S4
    L
    S2
    S3 & MEL Backlight Button
    Split Counter
    Split  Time                                        Lap Time
    Turbo Set upDisplay 
    						
    							
    DUAL SET-POINT TIMER 
    The watch has a count-down timer that 
    alarms when time is elapsed.  The timer 
    has two set-points, so that you can set 
    alternating intervals for training. This is 
    how the display looks in Timer Mode.
    0:00: 10
    0:00:08.8
    ACCUSPLIT
    ∞  S1/S4                                                               S2             AOS
    L
    E L
    S3M
    940MXTURBO
    5   2
    STOP
    Timer Set Instructions
    S1 (2 sec) - Enter set function OR  
    S1 (4sec) - Enter set function & clear the  
      current settings
    S2 select field to be set (selected field  
      will flash)
    S3 Set field to desired settings
    S4 exit setting function
    Fields to set are Hours, tens of minutes, 
    minutes, tens of seconds, and seconds 
    for First Inteval (Set Point), then same se-
    quence for Second Interval, then repeat.  
    The timer intreprets 0:00:00 as 30:00:00, 
    so set both Set Points to the same value 
    if you want  to repeatedly countdown 
    only one interval.
    Count Down or Count Up Timer Operat-
    ing Instructions
    S2 - Start.   
      Top line of display shows which Set 
     
      Point (1 or 2) you are timing. The 
     
      middle line shows the Time Interval for 
     
      the current Set Point.  The bottom line 
     
      of display shows the Time Remaining 
     
      (count down) for this Set Point.
    S2 - Stop  (Display also shows “STOP”)
    S2 (2sec) - Reset to beginning
    At end of the first time Interval, alarm 
    sounds for 5 seconds, and then the 
    watch begins counting down from the 
    second Set Point.  The timing cycle 
    repeats (Set Point #1, then Set Point #2, 
    etc.) until manually stopped.
    TIME OF DAY MODE
    The watch keeps track of two complete 
    sets of time/day/date/alarm info (T1 and 
    T2). “T2” shows when the watch is in 
    Time-of-Day mode #2. This is how the 
    display looks in Time-of-Day Mode:
        3-30 th
    9:25:44
    ACCUSPLIT
    ∞  S1/S4                                                               S2             AOS
    L
    E L
    S3M
    940MXTURBO
    T2
    Setting the Time of Day, Day-Date,  
    and Alarms
    Press (repeatedly until you are in T1 or  
      T2, as desired.
    S1 (2 sec) - Enter Set function
    S2 - select field to be set (field will flash)
    S3 - Set field to desired settings
    Using Time of Day, Day, Date &  
    Alarm Functions 
    S3 - Alternates between Alarm & Day- 
      Date Display
      Any button - Stops alarm sound
    	 While	in	 Alarm	Display:
    S2 - Changes Alarm & chime arm status:  
      Each press rotates through Alarm only 
     
      (display shows 
    1), Hourly chime  
      (display shows 
    +), or Both, then  
      neither.
    Power Reset:
    • Push and hold S2 and S3 - Display 
     
      turns OFF
    •  Release all - Display shows all 
     
      segments ON then displays stopwatch 
     
      at 0:00:00.00
    Changing the Battery
    When Low-Battery Indicator is “ON,” 
    replace the unit’s battery with a new Type 
    CR2016 Lithium cell, or equivalent.  
    PERFORMANCE SPECIFICATIONS
    Stopwatch Performance Function  
    & Features
    • 50 Dual Distance Split Automatic 
     
    REGISTER NOW.  Please return your A940MXT  registration to the Repair Center address in the warranty, and we will let you know about future 
    products.
     Memory
    •  Hour, Minute, Second to 1/100 Sec
    •  Speed & Rate Computations (Hr & 
     
      Min) (TURBO)
    •  Computers & Recalls Ave Speed/Rate 
     
      (TURBO)
    •  30 Hour Range
    •  Computers & Recalls Average Lap Split
    •  Anytime Memory Review
    •  Rapid Memory Review
    •  FIFS (First In First Saved) Memory
    •  LIFO (last in First out) Memory
    •  Display True Split Count
    •  1-Button Rapid Split & Reset Action
    •  Dual Split Timing
    •  Split Counter to 999 with Rollover
    •  Return to Running Dual Split
    Timer Performance Function & Features
    • 
    Dual Set-Point Timer Interval Memories
    •  Auto Repeat of Dual Interval Timer
    •  Display “1” or “2” for work or Rest 
     
      part of Cycle
    •  Display Current Cycle Count
    •  30 Hour Range (0:00:00=30:00:00)
    •  Hours, Minutes, Seconds Setting
    •  Hours, Minutes, Seconds, 1/10 Sec 
     
      Timing Display
    Time of Day and Time of Day Alarm  
    Functions and Features
    • Time Day-Month, Day, Alarm
    •  2nd Time, Date-Month, Day, Alarm
    •  Hourly Chime
    General Performance Features
    • 5 year NO-PROOF OF PURCHASE 
     
      Warranty
    •  NO-FAIL, Million – Cycle Switches
    •  Bold, Easy-to-Read Digits
    •  60 degree Comfort Viewing Angle
    •  Water Resistant
    •  Shock Resistant
    •  32,768Hz Quarts Crystal accuracy 
     
      to +or- 0.01 sec/hr
    •  1.5 Year Battery Life
    •  Low-Battery Indicator
    •  Accurate Temp: 5C-35C (41F-95F)
    •  Operating Temp: -10C0-60C (14F-140F)
    Assembled in China.  © ACCUSPLIT 2006
    Email __________________________
    User ___________________________
    _______________________________
    _______________________________
    Set Point Number  (1 or 2)
    Set Point  for timer
    Number of Cycles  Completed
    Time Remaining
    Watch is in Countdown Timer Mode
    Month, Date, and Day
    Time
    Indicates Watch in Time-of-Day Mode 2
    NO-PROOF-OF-PURCHASE LIMITED WARRANTYSee label on back of unit for details, or check  
    http://support.ACCUSPLIT.com 
    						
    All Accusplit manuals Comments (0)

    Related Manuals for Accusplit Stopwatch A940MXTBL User Manual