11 TECHNICAL RS-232C Communication (continued) Names Operation Type HeaderCommand Data CRC Action Type Setting Code OVER SCAN Get BE EF 03 06 00 91 70 02 00 09 22 00 00 Increment BE EF 03 06 00 F7 70 04 00 09 22 00 00 Decrement BE EF 03 06 00 26 71 05 00 09 22 00 00 OVER SCAN Reset Execute BE EF 03 06 00 EC D9 06 00 27 70 00 00 V POSITION Get BE EF 03 06 00 0D 83 02 00 00 21 00 00 Increment BE EF 03 06 00 6B 83 04 00 00 21 00 00 Decrement BE EF 03 06 00 BA 82 05 00 00 21 00 00 V POSITION Reset Execute BE EF 03 06 00 E0 D2 06 00 02 70 00 00 H POSITION Get BE EF 03 06 00 F1 82 02 00 01 21 00 00 Increment BE EF 03 06 00 97 82 04 00 01 21 00 00 Decrement BE EF 03 06 00 46 83 05 00 01 21 00 00 H POSITION Reset Execute BE EF 03 06 00 1C D3 06 00 03 70 00 00 H PHASE Get BE EF 03 06 00 49 83 02 00 03 21 00 00 Increment BE EF 03 06 00 2F 83 04 00 03 21 00 00 Decrement BE EF 03 06 00 FE 82 05 00 03 21 00 00 H SIZE Get BE EF 03 06 00 B5 82 02 00 02 21 00 00 Increment BE EF 03 06 00 D3 82 04 00 02 21 00 00 Decrement BE EF 03 06 00 02 83 05 00 02 21 00 00 H SIZE Reset Execute BE EF 03 06 00 68 D2 06 00 04 70 00 00 AUTO ADJUST Execute BE EF 03 06 00 91 D0 06 00 0A 20 00 00 COLOR SPACE Set AUTO BE EF 03 06 00 0E 72 01 00 04 22 00 00 RGB BE EF 03 06 00 9E 73 01 00 04 22 01 00 SMPTE240 BE EF 03 06 00 6E 73 01 00 04 22 02 00 REC709 BE EF 03 06 00 FE 72 01 00 04 22 03 00 REC601 BE EF 03 06 00 CE 70 01 00 04 22 04 00 Get BE EF 03 06 00 3D 72 02 00 04 22 00 00 COMPONENT Set COMPONENT BE EF 03 06 00 4A D7 01 00 17 20 00 00 SCART RGB BE EF 03 06 00 DA D6 01 00 17 20 01 00Get BE EF 03 06 00 79 D7 02 00 17 20 00 00 VIDEO FORMAT Set AUTO BE EF 03 06 00 9E 75 01 00 00 22 0A 00 NTSC BE EF 03 06 00 FE 71 01 00 00 22 04 00PAL BE EF 03 06 00 6E 70 01 00 00 22 05 00 SECAM BE EF 03 06 00 6E 75 01 00 00 22 09 00 NTSC4.43 BE EF 03 06 00 5E 72 01 00 00 22 02 00 M-PAL BE EF 03 06 00 FE 74 01 00 00 22 08 00 N-PAL BE EF 03 06 00 0E 71 01 00 00 22 07 00 Get BE EF 03 06 00 0D 73 02 00 00 22 00 00 © 3M 2004 3M™ Digital Projector X45/SX55 Downloaded From projector-manual.com 3M Manuals
12 RS-232C Communication (continued) Names Operation Type HeaderCommand Data CRC Action Type Setting Code FRAME LOCK Set TURN OFF BE EF 03 06 00 CB D6 01 00 14 30 00 00 TURN ON BE EF 03 06 00 5B D7 01 00 14 30 01 00Get BE EF 03 06 00 F8 D6 02 00 14 30 00 00 KEYSTONE V Get BE EF 03 06 00 B9 D3 02 00 07 20 00 00 Increment BE EF 03 06 00 DF D3 04 00 07 20 00 00 Decrement BE EF 03 06 00 0E D2 05 00 07 20 00 00 KEYSTONE V Reset Execute BE EF 03 06 00 08 D0 06 00 0C 70 00 00 WHISPER Set NORMAL BE EF 03 06 00 3B 23 01 00 00 33 00 00 WHISPER BE EF 03 06 00 AB 22 01 00 00 33 01 00Get BE EF 03 06 00 08 23 02 00 00 33 00 00 MIRROR Set NORMAL BE EF 03 06 00 C7 D2 01 00 01 30 00 00 H:INVERT BE EF 03 06 00 57 D3 01 00 01 30 01 00V:INVERT BE EF 03 06 00 A7 D3 01 00 01 30 02 00 H&V:INVERT BE EF 03 06 00 37 D2 01 00 01 30 03 00 Get BE EF 03 06 00 F4 D2 02 00 01 30 00 00 VOLUME Get BE EF 03 06 00 31 D3 02 00 01 20 00 00 Increment BE EF 03 06 00 57 D3 04 00 01 20 00 00 Decrement BE EF 03 06 00 86 D2 05 00 01 20 00 00 MUTE Set TURN OFF BE EF 03 06 00 46 D3 01 00 02 20 00 00 TURN ON BE EF 03 06 00 D6 D2 01 00 02 20 01 00 Get BE EF 03 06 00 75 D3 02 00 02 20 00 00 LANGUAGE Set ENGLISH BE EF 03 06 00 F7 D3 01 00 05 30 00 00 FRANÇAIS BE EF 03 06 00 67 D2 01 00 05 30 01 00 DEUTSCH BE EF 03 06 00 97 D2 01 00 05 30 02 00ESPAÑOL BE EF 03 06 00 07 D3 01 00 05 30 03 00ITALIANO BE EF 03 06 00 37 D1 01 00 05 30 04 00 NORSK BE EF 03 06 00 A7 D0 01 00 05 30 05 00 NEDERLANDS BE EF 03 06 00 57 D0 01 00 05 30 06 00 PORTUGUÊS BE EF 03 06 00 C7 D1 01 00 05 30 07 00 BE EF 03 06 00 37 D4 01 00 05 30 08 00 BE EF 03 06 00 A7 D5 01 00 05 30 09 00 BE EF 03 06 00 57 D5 01 00 05 30 0A 00 SVENSKA BE EF 03 06 00 C7 D4 01 00 05 30 0B 00 PУCCKИЙ BE EF 03 06 00 F7 D6 01 00 05 30 0C 00 SUOMI BE EF 03 06 00 67 D7 01 00 05 30 0D 00 POLSKI BE EF 03 06 00 97 D7 01 00 05 30 0E 00 Get BE EF 03 06 00 C4 D3 02 00 05 30 00 00 © 3M 2004 3M™ Digital Projector X45/SX55 Downloaded From projector-manual.com 3M Manuals
13 TECHNICAL RS-232C Communication (continued) Names Operation Type HeaderCommand Data CRC Action Type Setting Code MENU POSITION H Get BE EF 03 06 00 04 D7 02 00 15 30 00 00 Increment BE EF 03 06 00 62 D7 04 00 15 30 00 00 Decrement BE EF 03 06 00 B3 D6 05 00 15 30 00 00 MENU POSITION H Reset Execute BE EF 03 06 00 DC C6 06 00 43 70 00 00 MENU POSITION V Get BE EF 03 06 00 40 D7 02 00 16 30 00 00 Increment BE EF 03 06 00 26 D7 04 00 16 30 00 00 Decrement BE EF 03 06 00 F7 D6 05 00 16 30 00 00 MENU POSITION V Reset Execute BE EF 03 06 00 A8 C7 06 00 44 70 00 00 OSD BRIGHT Get BE EF 03 06 00 A8 D5 02 00 18 30 00 00 Increment BE EF 03 06 00 CE D5 04 00 18 30 00 00 Decrement BE EF 03 06 00 1F D4 05 00 18 30 00 00 BLANK Set My Screen BE EF 03 06 00 FB CA 01 00 00 30 20 00 ORIGINAL BE EF 03 06 00 FB E2 01 00 00 30 40 00BLUE BE EF 03 06 00 CB D3 01 00 00 30 03 00 WHITE BE EF 03 06 00 6B D0 01 00 00 30 05 00 BLACK BE EF 03 06 00 9B D0 01 00 00 30 06 00 Get BE EF 03 06 00 08 D3 02 00 00 30 00 00 BLANK On/Off Set TURN OFF BE EF 03 06 00 FB D8 01 00 20 30 00 00 TURN ON BE EF 03 06 00 6B D9 01 00 20 30 01 00Get BE EF 03 06 00 C8 D8 02 00 20 30 00 00 START UP Set My Screen BE EF 03 06 00 CB CB 01 00 04 30 20 00 ORIGINAL BE EF 03 06 00 0B D2 01 00 04 30 00 00 TURN OFF BE EF 03 06 00 9B D3 01 00 04 30 01 00 Get BE EF 03 06 00 38 D2 02 00 04 30 00 00 My Screen LOCK Set TURN OFF BE EF 03 06 00 3B EF 01 00 C0 30 00 00 TURN ON BE EF 03 06 00 AB EE 01 00 C0 30 01 00Get BE EF 03 06 00 08 EF 02 00 C0 30 00 00 Message Set TURN OFF BE EF 03 06 00 8F D6 01 00 17 30 00 00 TURN ON BE EF 03 06 00 1F D7 01 00 17 30 01 00Get BE EF 03 06 00 BC D6 02 00 17 30 00 00 AUTO SEARCH Set TURN OFF BE EF 03 06 00 B6 D6 01 00 16 20 00 00 TURN ON BE EF 03 06 00 26 D7 01 00 16 20 01 00Get BE EF 03 06 00 85 D6 02 00 16 20 00 00 AUTO POWER OFF Get BE EF 03 06 00 08 86 02 00 10 31 00 00 Increment BE EF 03 06 00 6E 86 04 00 10 31 00 00 Decrement BE EF 03 06 00 BF 87 05 00 10 31 00 00 © 3M 2004 3M™ Digital Projector X45/SX55 Downloaded From projector-manual.com 3M Manuals
14 RS-232C Communication (continued) Names Operation Type HeaderCommand Data CRC Action Type Setting Code LAMP TIME Get BE EF 03 06 00 C2 FF 02 00 90 10 00 00 LAMP TIME Reset Execute BE EF 03 06 00 58 DC 06 00 30 70 00 00 FILTER TIME Get BE EF 03 06 00 C2 F0 02 00 A0 10 00 00 FILER TIME Reset Execute BE EF 03 06 00 98 C6 06 00 40 70 00 00 MAGNIFY Get BE EF 03 06 00 7C D2 02 00 07 30 00 00 Increment BE EF 03 06 00 1A D2 04 00 07 30 00 00 Decrement BE EF 03 06 00 CB D3 05 00 07 30 00 00 FREEZE Set NORMAL BE EF 03 06 00 83 D2 01 00 02 30 00 00 FREEZE BE EF 03 06 00 13 D3 01 00 02 30 01 00 Get BE EF 03 06 00 B0 D2 02 00 02 30 00 00 © 3M 2004 3M™ Digital Projector X45/SX55 Downloaded From projector-manual.com 3M Manuals
3M Austin Center Building A145-5N-01 6801 River Place Blvd. Austin, TX 78726-90003M Canada P.O. Box 5757 London, Ontario N6A 4T13M Mexico, S.A. de C.V. Apartado Postal 14-139 Mexico, D.F. 07000 Mexico 3M Europe Boulevard de lOise 95006 Cerge Pontoise Cedex France Litho in Japan © 3M 2004 78-6970-9390-0 Rev. A Let us help you make the most of your next presentation. We offer every\ thing from presentation supplies to tips for better mee tings. And were the only transparency manufacturer that offers a recycling program for your used \ transparencies. For late-breaking news, handy referenc e and free product samples, call us toll-free in the continental United States and Canada, 24 hours a day\ , or visit our Internet Website. QR62261 Intended Use Before operating this machine, please read this entire manual thoroughly\ . The 3MTM Multimedia Projectors are designed, built, a nd tested for use indoors, using 3M lamps, 3M ceiling mount hardware, and nominal local voltages. The use of other replacement lamps, outdoor operation, or different volt\ ages has not been tested and could damage the projector peripheral equipment and/or create a potentially unsafe operating condition. 3M Multimedia projectors and Wall Display Systems are designed to operat\ e in a normal office environment. 16 to 29C (60 to 85 F) 10- 80 %RH (without condensation) 0- 1828 m (0-6000 feet) above sea level The ambient operating environment should be free of airborne smoke, grea\ se, oil and other contaminates that can affect the oper ation or performance of the projector. Use of this product in adverse conditions will void the product warranty\ . Downloaded From projector-manual.com 3M Manuals