4 Multifunctional settings ItemDescription SERVICE Selecting this item displays the SERVICE menu.Select an item using the buttons ▲/▼, and press the button ► or the ENTER button on the remote control to execute the item.FAN SPEED ó AUTO ADJUST ó GHOST ó FILTER MESSAG ó FACTORY RESET FAN SPEEDUsing the buttons ▲/▼ switches the rotation speed of the cooling fans. The HIGH is the mode for use at highlands etc. Note that the projector is noisier when the HIGH is selected. HIGH ó NORMAL AUTO ADJUSTUsing the buttons ▲/▼ enables/disables the automatic adjustment.When DISABLE is selected, the automatic adjustment feature is disabled, although rough adjustment is automatically performed depending on the basic setting. ENABLE ó DISABLE • Depending on conditions, such as input image, signal cable to the projector, environment around the projector, etc., the automatic adjustment may not work correctly. In such a case, please choose DISABLE to disable the automatic adjustment, and make adjustment manually. GHOST1. Select a color element of ghost using the buttons ◄/►. . Adjust the selected element using the buttons ▲/▼ to disappear ghost. FILTER MESSAGEUse the ▲/▼ button to set the timer for the interval to show the message for cleaning up the air filter. 50h ó 00h ó 00h ó 300h ó TURN OFFAfter selecting “50h”, “00h”, “00h”, or “300h”, the message “REMINDER ***HRS PASSED AFTER THE LAST FILTER CHECK” will appear after the timer reaches the interval time set by the menu. (40) When the “TURN OFF” is chosen, the air filter cleaning message will not appear.• Please check and clean the air filter periodically, even if there is no message. If the air filter becomes to be blocked by dust or others, the internal temperature will rise, which could cause malfunction, or reduce the lifetime of the projector.• It is recommended to choose “00h” in general. Please be careful with the operating environment of the projector and the condition of the air filter, especially when the “200h”, “300h or “TURN OFF” is chosen. FACTORY RESETSelecting RESET using the button ▲ performs this function. By this function, all the items in all of menus will collectively return to the initial se\ tting. Note that the items LAMP TIME, FILTER TIME and LANGUAGE are not reset. RESET CANCEL OPTION menu (continued)
4 Maintenance Maintenance Lamp WARNING HIGH VOLTAGE HIGH TEMPERATURE HIGH PRESSURE ►The projector uses a high-pressure mercury glass lamp. The lamp can break with a loud bang, or burn out, if jolted or scratched, handled while hot, or worn over time. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. In addition, when the bulb bursts, it is possible for shards of glass to fly into the lamp housing, and for gas containing mercury to escape from the projector’s vent holes. ►About disposal of a lamp • This product contains a mercury lamp; do not put in trash. Dispose of in accord with environmental laws.For lamp recycling, go to www.lamprecycle.org. (in the US) For product disposal, contact your local government agency or www.eiae.org (in the US) or www.epsc.ca (in Canada). For more information, call your dealer. • If the lamp should break (it will make a loud bang when it does), unplug the power cord from the outlet, and make sure to request a replacement lamp from your local dealer. Note that shards of glass could damage the projector’s internals, or cause injury during handling, so please do not try to clean the projector or replace the lamp yourself\ .• If the lamp should break (it will make a loud bang when it does), ventilate the room well, and make sure not to breathe the gas that comes out of the projector vents, or get it in your eyes or mouth.• Before replacing the lamp, turn the projector off and unplug the power cord, then wait at least 45 minutes for the lamp to cool sufficiently. Handling the lamp while hot can cause burns, as well as damaging the lamp. • Never unscrew except the appointed (marked by an arrow) screws. • Do not open the lamp door while the projector is suspended from above. This is dangerous, since if the lamp’s bulb has broken, the shards will fall out when the cover is opened. In addition, working in high places is dangerous, so ask your local dealer to have the lamp replaced even if the bulb is not broken.• Do not use the projector with the lamp door removed. At the lamp replacing, make sure that the screws are screwed in firmly. Loose screws could result in damage or injury. • Use only the lamp of the specified type. • If the lamp breaks soon after the first time it is used, it is possible that there are electrical problems elsewhere besides the lamp. If this happens, contact your local dealer or a service representative.• Handle with care: jolting or scratching could cause the lamp bulb to bur\ st during use.• If the indicators or a message prompts you to replace the lamp (see the section "Related Messages" and "Regarding the indicator Lamps"), replace the lamp as soon as possible. Using the lamp for long periods of time, or past the replacement date, could cause it to burst. Do not use old (used) lamps; this is a cause of breakage. Disconnect the plug from the power outlet
43 Lamp (continued) A lamp has a finite product life. Using the lamp for long periods of time could cause the pictures darker or the color tone poor. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start usi\ ng them. Preparation of a new lamp and early replacement are recommended. To prepare a new lamp, contact your dealer and tell the lamp type number. Type number = 78-6969-9812-5. . Turn the projector off, and unplug the power cord. Allow the lamp to cool for at least 45 minutes. . Prepare a new lamp. If the projector is mounted on the ceiling, or if the lamp has broken, a\ lso ask the dealer to replace the lamp. In the case of replacement by yourself, 3. After making sure that the projector has cooled adequately, slowly turn over the projector, so that the bottom is facing up. 4. Please loosen the screw (marked by arrow). Then, unhook the claws of the lamp door and remove the lamp door. 5. Loosen the screws (marked by arrow) of the lamp, and slowly pick up the lamp by the handles. 6. Insert the new lamp, and retighten firmly two screws that are loosened in the previous process to lock it in place. 7. Interlocking the tabs of the lamp door to the projector, position the lamp door on the projector, and push the center point of two claws to fix the lamp door. Then retighten firmly the screw of the lamp door. 8. Slowly turn the projector so that the top is facing up. 9. Turn the projector on and reset the lamp time using the LAMP TIME function in the OPTION menu (40). () Press the MENU button to display a menu. Only when the EASY MENU has appeared, please perform the next step (). (2) Point at the “Go To Advance Menu …” in the menu using ▼/▲ button, then press the ► button. (3) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then press the ► button. (4) Point at the ”LAMP TIME” using ▼/▲ button, then press the ► button. A dialog will appear. (5) Press the ▲ button to select “RESET” on the dialog. It performs resetting the lamp time. Maintenance NOTE • Please reset the lamp time only when you have replaced the lamp, for a suitable indication about the lamp. Claws of lamp door Screw marked by arrow Screws marked by arrow Tabs Center pointof claws
44 If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn and/or malfunction to the projector. When the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible.Please check and clean the air filter periodically, even if there is no message.Please replace the air filter when it is damaged or too soiled. Preparation of a new air filter is recommended.To prepare a new air filter, contact your dealer and tell the air filter type number. Type number = 78-8118-9584-2 And also when you replace the lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector . . Turn the projector off, and unplug the power cord. Allow the lamp to cool for at least 45 minutes. . Disconnect all the connectors and adapters that were connected to the pr\ ojector’s ports. Then slowly turn the projector so that the lens-side is facing up. Please be careful for a projector not to fall. While the projector is placed lens-side up, hold the projector. 3. Remove the filter cover and the air filter. Hold the knobs while pulling out it. 4. Apply a vacuum cleaner to the vent of the projector for the air filter. And then slowly turn the projector bottom up. Maintenance Usual filter cover Filter cover’s knobs Filter cover’s knobs Air filter’s knob Air filter Filter cover for bottom-up use WARNING ►Before caring, make sure the power switch is off and the power cable is not plugged in, then allow the projector to cool sufficiently. The care in a high temperature state of the projector could cause an electric shock, a\ burn and/or malfunction to the projector.►Use only the air filter of the specified type. Do not use the projector with the air filter and the filter cover removed. It could result in a fire and/or malfunction to the projector.►The air filter should be cleaned periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn and/or malfunction to the projector. NOTE • Please replace the air filter when it is damaged or too soiled, and also when you replace the lamp.• Please reset the filter time only when you have cleaned or replaced the air filter , for a suitable indication about the air filter. (40) • The projector may display the message such as “CHECK THE AIR FLOW” or turn off the projector, to prevent the internal heat level rising.
45 Maintenance Air filter (continued) 5. Apply a vacuum cleaner to the air filter and filter cover. Then set a new or cleaned air filter into place. In case of the filter cover for bottom-up use, remove the air filter from the filter cover and clean each. After cleaning, reattach the cleaned filter to the filter cover. Please replace the air filter when it is damaged or too soiled. 6. Position the air filter and filter cover into place. 7. Slowly turn the projector so that the top is facing up, except for the c\ ase of bottom-up use. 8. Turn the projector on and reset the filter time using the FILTER TIME function in the OPTION menu (40). () Press the MENU button to display a menu. When the EASY MENU has appeared, please skip the next step (). (2) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then press the ► button. (3) Point at the “FILTER TIME” using ▼/▲ button, then press the ► button. A dialog will appear. (4) Press the ▲ button to select “RESET” on the dialog. It performs resetting the filter time. ClawsAir filter Rail of air filter Filter cover for bottom-up use Usual filter coverPush the points of “PUSH” word with claws to fix the air filter.Interlocking the tabs, snap the filter cover into place. Filter cover for bottom-up useInterlocking the tabs, snap the filter cover into place. Tabs Tabs
46 Maintenance WARNING ►Do not take care of the projector during use or immediately after use. Handling while the projector is in a high temperature could cause a\ burn and/ or malfunction to the projector. Before operating, make sure that the power switch is off, that the power cord is not plugged in, and that the projector is cool\ adequately. ►Never try to care for the inside of the projector personally. Doing is so dangerous. ►Avoid wetting the projector or inserting liquids in the projector. It could result in a fire, an electric shock, and/or malfunction to the projector. • Don’t put a container containing water, cleaner or chemicals near the projector. • Don’t use aerosols or sprays. CAUTION ►Please take right care of the projector according to the following. Incorrect care could cause not only an injury but adverse influence such as discoloration, peeling paint, etc. • Do not use cleaner or chemicals other than those listed below. • Do not polish or wipe with hard objects. Inside of the projector In order to ensure the safe use of your projector, please have it cleaned and inspected by your dealer about once every year. Caring for the lens If the lens is flawed, soiled or fogged, it could cause deterioration of display quality. Please take care of the lens, being cautious of the handling. . Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. . After making sure that the projector is cool adequately, lightly wipe the lens with a commercially available lens-cleaning wipe. Do not touch the lens directly with your hand. Caring for the cabinet and remote control Incorrect care could have adverse influence such as discoloration, peeling paint, etc. . Turn the projector off, and unplug the power cord. Allow the projector to cool sufficiently. . After making sure that the projector is cool adequately, lightly wipe with gauze or a soft cloth. If soiling is severe, dip soft cloth in water or a neutral cleaner dilut\ e in water, and wipe lightly after wringing well. Then, wipe lightly with a soft, dry cloth. Other care
47 Troubleshooting Troubleshooting Related messages When the unit's power is on, messages such as those shown below may be displayed. When any such message is displayed on the screen, please resp\ ond as described below. If the same message is displayed after the treatment, or if a message other than the following appears, please contact your dealer or \ service company. Although these messages will be automatically disappeared around several\ minutes, it will be reappeared every time the power is turned on. MessageDescription NO INPUT IS DETECTEDON *** There is no input signal. Please confirm the signal input connection, and the status of the signal source. SYNC IS OUT OF RANGEON *** fH *****kHz fV *****Hz The horizontal or vertical frequency of the input signal is not within the specified range. Please confirm the specs for this unit or the signal source specs. CHECK THE AIR FLOW The internal portion temperature is rising. Please turn the power OFF, and allow the unit to cool down at least 20 minutes. After having confirmed the following items, please turn the power ON again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? • If the same indication is displayed after the treatment, please set the HIGH at the FAN SPEED of the item SERVICE of the OPTION menu. REMINDER *** HRS PASSED AFTER THE LAST FILTER CHECK. FILTER MAINTENANCE IS ESSENTIAL TO REMOVE WARNING MESSAGE, RESET FILTER TIMER. SEE MANUAL FURTHER INFO. A note of precaution when cleaning the air filter. Please immediately turn the power OFF, and clean or change the air filter by referring to the “Air Filter” section of this manual. After you have cleaned or changed the air filter, please be sure to reset the filter timer (40).
48 Troubleshooting Regarding the indicator lamps Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the table below. Please respond in accordance with the instructions within the table. If the same indica\ tion is displayed after the treatment, or if an indication other than the follow\ ing is displayed, please contact your dealer or service company. POWER indicator LAMP indicator TEMP indicatorDescription Lighting In Orange Turned off Turned off The projector is in a standby state. Please refer to the section “Power On/Off”. (17) Blinking In Green Turned off Turned off The projector is warming up. Please wait. Lighting In Green Turned off Turned off The projector is in an on state. Ordinary operations may be performed. Blinking In Orange Turned off Turned off The projector is cooling down. Please wait. Blinking In Red (discre- tionary) (discre- tionary) The projector is cooling down. A certain error has been detected. Please wait until the POWER indicator finishes blink, and then perform the proper response measure using the item descriptions below as reference. Blinking In Red or Lighting In Red Lighting In Red Turned off The lamp does not light, and there is a possibility that interior portion has become heated. Please turn the power off, and allow the unit to cool down at least 0 minutes. After the projector has sufficiently cooled down, please make confirmation of the following items, and then turn the power on again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? If the same indication is displayed after the treatment, please change the lamp by referring to the section “Lamp”. (42) Blinking In Red or Lighting In Red Blinking In Red Turned off The lamp door has not been properly fixed (attached). Please turn the power off, and allow the unit to cool down at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp door. After performing any needed maintenance, turn the power on again. If the same indication is displayed after the treatment, please contact your dealer or service company.
49 Troubleshooting Regarding the indicator lamps (continued) POWER indicator LAMP indicator TEMP indicatorDescription Blinking In Red or Lighting In Red Turned off Blinking In Red The cooling fan is not operating. Please turn the power off, and allow the unit to cool down at least 0 minutes. After the projector has sufficiently cooled down, please make confirmation that no foreign matter has become caught in the fan, etc. and then turn the power on again. If the same indication is displayed after the treatment, please contact your dealer or service company. Blinking In Red or Lighting In Red Turned off Lighting In Red There is a possibility that the interior portion has become heated. Please turn the power off, and allow the unit to cool down at least 0 minutes. After the projector has sufficiently cooled down, please make confirmation of the following items, and then turn the power on again. • Is there blockage of the air passage aperture? • Is the air filter dirty? • Does the peripheral temperature exceed 35°C? If the same indication is displayed after the treatment, please set the HIGH at the FAN SPEED of the item SERVICE of the OPTION menu. (41) Lighting In Green Alternative blinking in Red There is a possibility that the interior portion has become overcooled. Please use the unit within the usage temperature parameters (5°C to 35°C). After the treatment, resent the power to ON. Lighting In Green Simultaneous blinking in Red It is time to clean the air filter. Please immediately turn the power OFF, and clean or change the air filter by referring to the section “Air Filter”. After cleaning or changed the air filter, please be sure to reset the filter timer. After the treatment, resent the power to ON. NOTE • When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “” (OFF) side of the power switch, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp door, and then turn the power on again.
50 Troubleshooting Phenomena that may easily be mistaken for machine defects WARNING ►Never use the projector if abnormal operations such as smoke, strange odor, excessive sound, damaged casing or elements or cables, penetration of liquids or foreign matter, etc. should occur. In such cases, immediately turn off the power switch and then disconnect the power plug from the power outlet. After making sure that the smoke or odor has stopped, contact your dealer or service company. . Before requesting repair, please check in accordance with the following chart. This operation sometimes resolves your problem. If the situation cannot be corrected, . The projector’s microprocessor may need to be reset. Please push the restart switch by using a pin or similar. 3. Some setting may be wrong. Please use the FACTORY RESET function of SERVICE menu in the OPTION menu (41) to reset all settings to factory default. Then, if the problem is not removed after maintenance, please contact yo\ ur dealer or service company. PhenomenonCases not involving a machine defectReference page Power does not come on. The electrical power cord is not plugged in. Correctly connect the power cord.6 The power switch is not set to the on position. Set the power switch to [ | ] (On).7 The main power source has been interrupted during operation such as by a power outage (blackout), etc. Please turn the power off, and allow the unit to cool down at least 20 minutes. After the projector has sufficiently cooled down, please turn the power on again. 7, 8 Either there is no lamp and/or lamp door, or either of these has not been properly fixed. Please turn the power off, and allow the unit to cool down at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp door, and then turn the power on again. 4, 43