Home > 3M > Projector > 3M Multimedia Projector X15i Operators Guide

3M Multimedia Projector X15i Operators Guide

    Download as PDF Print this page Share this page

    Have a look at the manual 3M Multimedia Projector X15i Operators Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 307 3M manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    4
    
    Multifunctional settings
    ItemDescription
    SERVICE
    Selecting this item displays the SERVICE menu.Select an item using the buttons ▲/▼, and press the button ► or the ENTER button on the remote control to execute the item.FAN SPEED ó AUTO ADJUST ó GHOST ó FILTER MESSAG ó FACTORY RESET       FAN SPEEDUsing the buttons ▲/▼ switches the rotation speed of the cooling fans. The HIGH is the mode for use at highlands etc. Note that the projector is noisier when the HIGH is selected.
    HIGH ó NORMAL
    AUTO ADJUSTUsing the buttons ▲/▼ enables/disables the automatic adjustment.When DISABLE is selected, the automatic adjustment feature is disabled, although rough adjustment is automatically performed depending on the basic setting.
    ENABLE ó DISABLE
    • Depending on conditions, such as input image, signal cable to the projector, environment around the projector, etc., the automatic adjustment may not work correctly.  In such a case, please choose DISABLE to disable the automatic adjustment, and make adjustment manually.
    GHOST1.  Select a color element of ghost using the buttons ◄/►. .  Adjust the selected element using the buttons ▲/▼ to disappear ghost.
    FILTER MESSAGEUse the ▲/▼ button to set the timer for the interval to show the message for cleaning up the air filter. 50h ó 00h ó 00h ó 300h ó TURN OFFAfter selecting “50h”, “00h”, “00h”, or “300h”, the message “REMINDER ***HRS PASSED AFTER THE LAST FILTER CHECK” will appear after the timer reaches the interval time set by the menu. (40) When the “TURN OFF” is chosen, the air filter cleaning message will not appear.• Please check and clean the air filter periodically, even if there is no message. If the air filter becomes to be blocked by dust or others, the internal temperature will rise, which could cause malfunction, or reduce the lifetime of the projector.• It is recommended to choose “00h” in general. Please be careful with the operating environment of the projector and the condition of the air filter, especially when the “200h”, “300h or “TURN OFF” is chosen. FACTORY RESETSelecting RESET using the button ▲ performs this function. By this function, all the items in all of menus will collectively return to the initial se\
    tting. Note that the items LAMP TIME, FILTER TIME and LANGUAGE are not reset.
    RESET  CANCEL
    OPTION menu (continued) 
    						
    							
    4
    
    Maintenance
    Maintenance
    Lamp
     WARNING HIGH VOLTAGE HIGH TEMPERATURE HIGH PRESSURE
    ►The  projector  uses  a  high-pressure  mercury  glass  lamp.  The  lamp  can break 
    with  a  loud  bang,  or  burn  out,  if  jolted  or  scratched,  handled  while  hot,  or  worn over  time.  Note  that  each  lamp  has  a  different  lifetime,  and  some  may  burst  or burn  out  soon  after  you  start  using  them.  In  addition,  when  the  bulb  bursts,  it  is possible  for shards  of  glass  to  fly  into  the  lamp  housing,  and  for gas  containing mercury to escape from the projector’s vent holes.
    ►About disposal of a lamp  • This product contains a mercury lamp; do not 
    put in trash. Dispose of in accord with environmental laws.For lamp recycling, go to www.lamprecycle.org. (in the US) For product disposal, contact your local government agency or www.eiae.org (in the US) or www.epsc.ca (in Canada). For more information, call your dealer.
    • If  the  lamp  should  break  (it  will  make  a  loud  bang  when  it  does), 
    unplug  the  power  cord  from  the  outlet,  and  make  sure  to  request  a replacement  lamp  from  your  local  dealer.  Note  that  shards  of  glass could damage the projector’s internals, or cause injury during handling, so please do not try to clean the projector or replace the lamp yourself\
    .•  If  the  lamp  should  break  (it  will  make  a  loud  bang  when  it  does), ventilate  the  room  well,  and  make  sure  not  to  breathe  the  gas  that comes out of the projector vents, or get it in your eyes or mouth.• Before replacing the lamp, turn the projector off and unplug the power cord,  then  wait  at  least  45  minutes  for  the  lamp  to  cool  sufficiently. 
    Handling  the  lamp  while  hot  can  cause  burns,  as  well  as  damaging  the lamp.
    • Never unscrew except the appointed (marked by an arrow) screws.
    •  Do  not  open  the  lamp  door  while  the  projector  is  suspended  from above.  This  is  dangerous,  since  if  the  lamp’s  bulb  has  broken,  the shards  will  fall  out  when  the  cover  is  opened.  In  addition,  working  in high  places  is  dangerous,  so  ask  your  local  dealer  to  have  the  lamp replaced even if the bulb is not broken.•  Do  not  use  the  projector  with  the  lamp  door  removed.  At  the  lamp replacing,  make  sure  that  the  screws  are  screwed  in  firmly.  Loose screws could result in damage or injury.
    • Use only the lamp of the specified type.
    •  If  the  lamp  breaks  soon  after  the  first  time  it  is  used,  it  is  possible that  there  are  electrical  problems  elsewhere  besides  the  lamp.  If  this happens, contact your local dealer or a service representative.• Handle with care: jolting or scratching could cause the lamp bulb to bur\
    st during use.•  If  the  indicators  or  a  message  prompts  you  to  replace  the  lamp  (see the  section  "Related  Messages"  and  "Regarding  the  indicator  Lamps"), replace  the  lamp  as  soon  as  possible.  Using  the  lamp  for  long  periods of  time,  or  past  the  replacement  date,  could  cause  it  to  burst.  Do  not use old (used) lamps; this is a cause of breakage.
    Disconnect the plug from the power outlet 
    						
    							
    43
    
    Lamp (continued)
    A lamp has a finite product life. Using the lamp for long periods of time could 
    cause the pictures darker or the color tone poor. Note that each lamp has a 
    different lifetime, and some may burst or burn out soon after you start usi\
    ng them. 
    Preparation of a new lamp and early replacement are recommended. 
    To prepare a new lamp, contact your dealer and tell the lamp type number.
    Type number = 78-6969-9812-5.
    . Turn the projector off, and unplug the power cord. Allow the lamp to cool for 
    at least 45 minutes.
    . Prepare a new lamp.  
    If the projector is mounted on the ceiling, or if the lamp has broken, a\
    lso ask 
    the dealer to replace the lamp.
    In the case of replacement by yourself,
    3. After making sure that the projector has cooled 
    adequately, slowly turn over the projector, so 
    that the bottom is facing up.
    4. Please loosen the screw (marked by arrow). Then, unhook 
    the claws of the lamp door and remove the lamp door.
    5. Loosen the  screws (marked by arrow) of the lamp, 
    and slowly pick up the lamp by the handles.
    6. Insert the new lamp, and retighten firmly two 
    screws that are loosened in the previous 
    process to lock it in place.
    7. Interlocking the  tabs of the lamp door to 
    the projector, position the lamp door on the 
    projector, and push the center point of two 
    claws to fix the lamp door. Then retighten firmly 
    the screw of the lamp door.
    8. Slowly turn the projector so that the top is facing up.
    9. Turn the projector on and reset the lamp time using 
    the LAMP TIME function in the OPTION menu (40). 
    () Press the MENU button to display a menu. Only when the EASY MENU has 
    appeared, please perform the next step ().
    (2) Point at the “Go To Advance Menu …” in the menu using ▼/▲ button, then 
    press the ► button. 
    (3) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then 
    press the ► button.
    (4) Point at the ”LAMP TIME” using ▼/▲ button, then press the ► button. A dialog will appear.
    (5) Press the ▲ button to select “RESET” on the dialog. It performs resetting the lamp time.
    Maintenance
    NOTE  • Please reset the lamp time only when you have replaced the lamp, 
    for a suitable indication about the lamp.
    Claws of lamp door
    Screw marked by arrow
    Screws marked by arrow
    Tabs
    Center pointof claws 
    						
    							
    44
    
    If  the  air  filter  becomes  clogged  by  dust  or  the  like,  internal  temperatures  rise  and  could cause a fire, a burn and/or malfunction to the projector. When the indicators or a message prompts you to clean the air filter, clean the air filter as soon as possible.Please check and clean the air filter periodically, even if there is no message.Please replace the air filter when it is damaged or too soiled. Preparation of a new air filter is recommended.To prepare a new air filter, contact your dealer and tell the air filter type number.
    Type number = 78-8118-9584-2
    And  also  when  you  replace  the  lamp,  please  replace  the  air  filter.  An  air  filter  of specified type will come together with a replacement lamp for this projector .
    . Turn the projector off, and unplug the power cord. Allow the lamp to cool for at least 45 minutes.
    . Disconnect all the connectors and adapters that were connected to the pr\
    ojector’s ports. Then slowly turn the projector so that the lens-side is facing up. Please be careful for a projector not to fall. While the projector is placed lens-side up, hold the projector.
    3. Remove the filter cover and the air filter. Hold the knobs while pulling out it.
    4. Apply a vacuum cleaner to the vent of the projector for the air filter. And then slowly turn the projector bottom up.
    Maintenance
    Usual filter cover
    Filter cover’s  knobs
    Filter cover’s  knobs
    Air filter’s knob
    Air filter
    Filter cover for bottom-up use
    WARNING  ►Before caring, make sure the power switch is off and the power 
    cable is not plugged in, then allow the projector to cool sufficiently. The care in a 
    high temperature state of the projector could cause an electric shock, a\
     burn and/or malfunction to the projector.►Use only the air filter of the specified type. Do not use the projector with the air filter and the filter cover removed. It could result in a fire and/or malfunction to the projector.►The air filter should be cleaned periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn and/or malfunction to the projector.
    NOTE  • Please replace the air filter when it is damaged or too soiled, and also when you replace the lamp.• Please reset the filter time only when you have cleaned or replaced the air filter , for a suitable indication about the air filter. (40)
    • The projector may display the message such as “CHECK THE AIR FLOW” or turn off the projector, to prevent the internal heat level rising. 
    						
    							
    45
    
    Maintenance
    Air filter (continued)
    5. Apply a vacuum cleaner to the air filter and filter cover. 
    Then set a new or cleaned air filter into place. 
    In case of the filter cover for bottom-up use, remove the air filter from the filter 
    cover and clean each. After cleaning, reattach the cleaned filter to the filter cover.
    Please replace the air filter when it is damaged or too soiled.
    6. Position the air filter and filter cover into place.
    7. Slowly turn the projector so that the top is facing up, except for the c\
    ase of 
    bottom-up use.
    8. Turn the projector on and reset the filter time using the FILTER TIME function 
    in the OPTION menu (40). 
    () Press the MENU button to display a menu. When the EASY MENU has 
    appeared, please skip the next step ().
    (2) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then 
    press the ► button.
    (3) Point at the “FILTER TIME” using ▼/▲ button, then press the ► button. A 
    dialog will appear.
    (4) Press the ▲ button to select “RESET” on the dialog. It performs resetting the 
    filter time. 
    ClawsAir filter
    Rail of air filter
    Filter cover for bottom-up use
    Usual filter coverPush the points of “PUSH” word with claws to fix the air filter.Interlocking the tabs, snap the filter cover into place.
    Filter cover for bottom-up useInterlocking the tabs, snap the filter cover into place.
    Tabs
    Tabs 
    						
    							
    46
    
    Maintenance
    WARNING  ►Do not take care of the projector during use or immediately after 
    use. Handling while the projector is in a high temperature could cause a\
     burn and/
    or malfunction to the projector. Before operating, make sure that the power switch is 
    off, that the power cord is not plugged in, and that the projector is cool\
     adequately.
    ►Never try to care for the inside of the projector personally. Doing is so 
    dangerous. 
    ►Avoid wetting the projector or inserting liquids in the projector. It could result 
    in a fire, an electric shock, and/or malfunction to the projector. 
    • Don’t put a container containing water, cleaner or chemicals near the 
    projector. 
    • Don’t use aerosols or sprays.
    CAUTION  ►Please take right care of the projector according to the 
    following. Incorrect care could cause not only an injury but adverse influence 
    such as discoloration, peeling paint, etc. 
    • Do not use cleaner or chemicals other than those listed below. 
    • Do not polish or wipe with hard objects.
    Inside of the projector
    In order to ensure the safe use of your projector, please have it cleaned and 
    inspected by your dealer about once every year.
    Caring for the lens
    If the lens is flawed, soiled or fogged, it could cause deterioration of display 
    quality. Please take care of the lens, being cautious of the handling.
    . Turn the projector off, and unplug the power cord. Allow the projector to cool 
    sufficiently.
    . After making sure that the projector is cool adequately, lightly wipe the lens 
    with a commercially available lens-cleaning wipe. Do not touch the lens 
    directly with your hand.
    Caring for the cabinet and remote control
    Incorrect care could have adverse influence such as discoloration, peeling paint, 
    etc.
    . Turn the projector off, and unplug the power cord. Allow the projector to cool 
    sufficiently.
    . After making sure that the projector is cool adequately, lightly wipe with gauze 
    or a soft cloth. 
    If soiling is severe, dip soft cloth in water or a neutral cleaner dilut\
    e in water, 
    and wipe lightly after wringing well. Then, wipe lightly with a soft, dry cloth.
    Other care  
    						
    							
    47
    
    Troubleshooting
    Troubleshooting
    Related messages
    When the unit's power is on, messages such as those shown below may be 
    displayed. When any such message is displayed on the screen, please resp\
    ond 
    as described below. If the same message is displayed after the treatment, or if a 
    message other than the following appears, please contact your dealer or \
    service 
    company.
    Although these messages will be automatically disappeared around several\
     
    minutes, it will be reappeared every time the power is turned on.
    MessageDescription
    NO INPUT IS DETECTEDON ***
    There is no input signal. 
    Please confirm the signal input connection, and the status 
    of the signal source.
    SYNC IS OUT OF RANGEON ***  fH  *****kHz  fV  *****Hz
    The horizontal or vertical frequency of the input 
    signal is not within the specified range. 
    Please confirm the specs for this unit or the signal source specs.
    CHECK THE AIR FLOW
    The internal portion temperature is rising. 
    Please turn the power OFF, and allow the unit to cool 
    down at least 20 minutes. After having confirmed the 
    following items, please turn the power ON again. 
     • Is there blockage of the air passage aperture? 
     • Is the air filter dirty? 
     • Does the peripheral temperature exceed 35°C?
     • If the same indication is displayed after the treatment, 
    please set the HIGH at the FAN SPEED of the item 
    SERVICE of the OPTION menu.
    REMINDER
    *** HRS PASSED AFTER THE 
    LAST FILTER CHECK. 
    FILTER MAINTENANCE IS ESSENTIAL
     TO REMOVE WARNING MESSAGE,
    RESET FILTER TIMER.
    SEE MANUAL FURTHER INFO.
    A note of precaution when cleaning the air filter. 
    Please immediately turn the power OFF, and clean or 
    change the air filter by referring to the “Air Filter” section 
    of this manual. After you have cleaned or changed the air 
    filter, please be sure to reset the filter timer (40).  
    						
    							
    48
    
    Troubleshooting
    Regarding the indicator lamps
    Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP 
    indicator have the meanings as described in the table below. Please respond 
    in accordance with the instructions within the table. If the same indica\
    tion is 
    displayed after the treatment, or if an indication other than the follow\
    ing is 
    displayed, please contact your dealer or service company.
    POWER 
    indicator
    LAMP 
    indicator
    TEMP 
    indicatorDescription
    Lighting
    In Orange
    Turned
    off
    Turned
    off
    The projector is in a standby state.
    Please refer to the section “Power On/Off”. (17)
    Blinking
    In Green
    Turned
    off
    Turned
    off
    The projector is warming up.
    Please wait.
    Lighting
    In Green
    Turned
    off
    Turned
    off
    The projector is in an on state.
    Ordinary operations may be performed.
    Blinking
    In Orange
    Turned
    off
    Turned
    off
    The projector is cooling down.
    Please wait.
    Blinking
    In Red
    (discre-
    tionary)
    (discre-
    tionary)
    The projector is cooling down. A certain error 
    has been detected.
    Please wait until the POWER indicator finishes blink, 
    and then perform the proper response measure using 
    the item descriptions below as reference.
    Blinking
    In Red
    or
    Lighting
    In Red
    Lighting
    In Red
    Turned
    off
    The lamp does not light, and there is a 
    possibility that interior portion has become 
    heated.
    Please turn the power off, and allow the unit to cool 
    down at least 0 minutes. After the projector has 
    sufficiently cooled down, please make confirmation of 
    the following items, and then turn the power on again.
    • Is there blockage of the air passage aperture?
    • Is the air filter dirty?
    • Does the peripheral temperature exceed 35°C?
    If the same indication is displayed after the treatment, 
    please change the lamp by referring to the section 
    “Lamp”. (42)
    Blinking
    In Red
    or
    Lighting
    In Red
    Blinking
    In Red
    Turned
    off
    The lamp door has not been properly fixed 
    (attached).
    Please turn the power off, and allow the unit to cool 
    down at least 45 minutes. After the projector has 
    sufficiently cooled down, please make confirmation of 
    the attachment state of the lamp door. After performing 
    any needed maintenance, turn the power on again. If 
    the same indication is displayed after the treatment, 
    please contact your dealer or service company. 
    						
    							
    49
    
    Troubleshooting
    Regarding the indicator lamps (continued)
    POWER 
    indicator
    LAMP 
    indicator
    TEMP 
    indicatorDescription
    Blinking
    In Red
    or
    Lighting
    In Red
    Turned
    off
    Blinking
    In Red
    The cooling fan is not operating.
    Please turn the power off, and allow the unit to cool 
    down at least 0 minutes. After the projector has 
    sufficiently cooled down, please make confirmation 
    that no foreign matter has become caught in the fan, 
    etc. and then turn the power on again.
    If the same indication is displayed after the treatment, 
    please contact your dealer or service company.
    Blinking
    In Red
    or
    Lighting
    In Red
    Turned
    off
    Lighting
    In Red
    There is a possibility that the interior portion 
    has become heated.
    Please turn the power off, and allow the unit to cool 
    down at least 0 minutes. After the projector has 
    sufficiently cooled down, please make confirmation of 
    the following items, and then turn the power on again.
    • Is there blockage of the air passage aperture?
    • Is the air filter dirty?
    • Does the peripheral temperature exceed 35°C?
    If the same indication is displayed after the treatment, 
    please set the HIGH at the FAN SPEED of the item 
    SERVICE of the OPTION menu. (41)
    Lighting
    In Green
    Alternative
    blinking in Red
    There is a possibility that the interior portion 
    has become overcooled.
    Please use the unit within the usage temperature 
    parameters (5°C to 35°C). After the treatment, resent 
    the power to ON.
    Lighting
    In Green
    Simultaneous
    blinking in Red
    It is time to clean the air filter.
    Please immediately turn the power OFF, and clean 
    or change the air filter by referring to the section “Air 
    Filter”. After cleaning or changed the air filter, please 
    be sure to reset the filter timer. After the treatment, 
    resent the power to ON.
    NOTE  • When the interior portion has become overheated, for safety 
    purposes, the power source is automatically turned off, and the indicator lamps 
    may also be turned off. In such a case, press the “” (OFF) side of the power 
    switch, and wait at least 45 minutes. After the projector has sufficiently cooled 
    down, please make confirmation of the attachment state of the lamp and lamp 
    door, and then turn the power on again. 
    						
    							
    50
    
    Troubleshooting
    Phenomena that may easily be mistaken for machine defects
    WARNING  ►Never use the projector if abnormal operations such as 
    smoke, strange odor, excessive sound, damaged casing or elements or cables, 
    penetration of liquids or foreign matter, etc. should occur. In such cases, 
    immediately turn off the power switch and then disconnect the power plug from 
    the power outlet. After making sure that the smoke or odor has stopped, contact 
    your dealer or service company.
    . Before requesting repair, please check in 
    accordance with the following chart. This 
    operation sometimes resolves your problem.
    If the situation cannot be corrected, 
    . The projector’s microprocessor may need to be reset. Please push the restart 
    switch by using a pin or similar.
    3. Some setting may be wrong. Please use the FACTORY RESET function of 
    SERVICE menu in the OPTION menu (41) to reset all settings to factory 
    default.
    Then, if the problem is not removed after maintenance, please contact yo\
    ur dealer 
    or service company.
    PhenomenonCases not involving a machine defectReference
    page 
    Power does not 
    come on.
    The electrical power cord is not plugged in.
    Correctly connect the power cord.6
    The power switch is not set to the on position.
    Set the power switch to [ | ] (On).7
    The main power source has been interrupted during 
    operation such as by a power outage (blackout), etc.
    Please turn the power off, and allow the unit to cool down at 
    least 20 minutes. After the projector has sufficiently cooled 
    down, please turn the power on again.
    7, 8
    Either there is no lamp and/or lamp door, or either of 
    these has not been properly fixed.
    Please turn the power off, and allow the unit to cool down at 
    least 45 minutes. After the projector has sufficiently cooled 
    down, please make confirmation of the attachment state of 
    the lamp and lamp door, and then turn the power on again.
    4, 43 
    						
    All 3M manuals Comments (0)