Home > 3M > Projector > 3M Multimedia Projector Mp7730 Operators Manual

3M Multimedia Projector Mp7730 Operators Manual

Here you can view all the pages of manual 3M Multimedia Projector Mp7730 Operators Manual. The 3M manuals for Projector are available online for free. You can easily download all the documents as PDF.

Page 21

213M™ Multimedia Projector MP7730
© 3M IPC 2000
Operation Menu
Auto Off
Mirror
Normal V-Inv (Vertically Inverted) H-Inv (Horizontally
Inverted)H/V-Inv (Horizontally and
   Vertically Inverted)
LanguageEnglish (En)     French (Fr)      Deutsch (De)     Italian (It)     Español (Es)
Swedish (Sv)    Dutch (Ne)
00:00:00 00:60:00
Will turn off the power in 60 minutes.
Will restore the projector to factory default settings. Will invert image to display properly according to position of projector.
Reset
Off On...

Page 22

3M™ Multimedia Projector MP773022© 3M IPC 2000
Shutdown
1. Press the STANDBY/ON button. The Shutdown screen will display. Select the YES option (press arrow
button or mini-joystick) to turn off.
2. The fan will continue to run for approximately 90 seconds.
3.Disconnect power cord from wall socket.
4. Disconnect cables if moving projector to new location.
Do not unplug power cord before pressing the STANDBY/ON button. After the
STANDBY/ON button is pressed, the fan rotates for about 90 seconds to cool...

Page 23

233M™ Multimedia Projector MP7730
© 3M IPC 2000
Optional Video  Module
Features
Optional Video Module Connections
Laser Disc
S-VHS
RED WHTOUT
OUT
IN
IN IN IN
VCR
RED WHT YEL
OUT OUT OUT
Audio L
Audio R
Video
Audio L
Audio R
OUT
IN
Cable
The Optional Video Module makes it possible to hook the MP7730 to a laser disc, VCR, or other
video devices. Two versions will be available: an NTSC Package (with RCA connectors and televi-
sion tuner), and a PAL package (with a SCART connector and no television tuner)....

Page 24

3M™ Multimedia Projector MP773024© 3M IPC 2000
L
o
c
k
MP7630
D
L
PA
 
T
E
X
A
S
 
I
N
S
T
R
U
M
E
N
T
S
 
P
R
O
D
U
C
T
Attaching the Optional Video Module to the MP7730
STANDBY/ONMP7630
M
E
N
U
E
X
IT
1. Precisely align the two metal tabs on the bottom of the module and insert into the corresponding
slots on the back of the projector.
2. Slowly push the module to fit with the unit. Make sure that the module plugs into the AV con
nection on the projector.
3. Plug the correct cable into the corresponding...

Page 25

253M™ Multimedia Projector MP7730
© 3M IPC 2000
Image Sub-Menu
This menu is only available when the input signal is from Video, S-Video, TV or CATV.
}
System Image Ratio
Color
-123-
Tint4:9 (Normal)AutoPAL-MPAL-NSECAM
16:9 (Video)
-123-
Optional Video  Module
Color
Tint
Image Ratio
System
Auto PAL-M PAL-N SECAM4:9 (Normal) 16:9 (Video) Red Green           (Source is video or S-video) Less  More 

Page 26

3M™ Multimedia Projector MP773026© 3M IPC 2000
Operation
1. Go into the menu system and move to the Source sub-menu. Use the Menu key on the control pad
or remote control unit to scroll through items in the sub-menu. Select the Tuner items and press
     or       keys to prompt out of the tuner menu.
Optional Video  Module
Volume Source
15
Treble8
Bass8
Mute
Tuner               Press  to select
PCVideo
OffOn
S-VideoTuner
}
2. Use the Menu key on the control pad or remote control unit to scroll through...

Page 27

273M™ Multimedia Projector MP7730
© 3M IPC 2000
3. After leaving the menu system, press the Scan button to scan all existing channels in that region.
 Note: Scan function must be done for the first use in certain regions to catch all the channels
in the local CATV system.
Optional Video  Module
START SCANNING?
Ye s N o
After the “Start scanning” dialog box prompt, use the channel up/down key to select “Ye s” or “No.”
Press Return key to set.
Function (Must be performed with remote control unit)
Channel...

Page 28

3M™ Multimedia Projector MP773028© 3M IPC 2000
Source Menu
Optional Video  Module
Volume Source
15
Treble8
Bass8
Mute
Tuner               Press  to select
PCVideo
OffOn
S-VideoTuner
} 

Page 29

293M™ Multimedia Projector MP7730
© 3M IPC 2000
Use and Replacement of Lamp Lamp
The projector lamp has a normal operating time of approximately 1200 to 1500 hours, called the lamp
life. During the normal lamp life, the picture will be bright and the colors clear. If the lamp is used
beyond the normal lamp life, the picture will become dark and the colors poor. Always replace lamps
with new ones. Using an old lamp in the projector could cause a malfunction. When the power is
turned on, the LAMP indicator...

Page 30

3M™ Multimedia Projector MP773030© 3M IPC 2000
Lamp Replacement
 Note: For maximum lamp life, do not shock, handle or scratch the lamp glass when it is hot.
Also, do not use an old or previously used lamp as a replacement lamp.
WARNINGTo reduce the risk of electrical shock, always turn off projector and disconnect
power cord before changing lamp.
To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes before replacing the
lamp.
To reduce the risk of cuts to fingers and...
Start reading 3M Multimedia Projector Mp7730 Operators Manual

Related Manuals for 3M Multimedia Projector Mp7730 Operators Manual

All 3M manuals