    							ItemDescription
    VOLUMEVolume Adjustment :Press the VOLUME / button.
    MUTESet/Clear Mute Mode :Press the MUTE button. No sound is heard in the
    MUTE mode.
    AUTO
    Automatic Adjustment at RGB Input :Press the AUTO button. Horizontal
    position(H.POSIT), vertical position (V.POSIT),clock phase (H.PHASE), and
    horizontal size(H.SIZE) are automatically adjusted. Use with the window at
    maximum size in the application display.
    Automatic Adjustment at Video Input :Press the AUTO button. A signal
    type appropriate for the input signal is selected automatically. Valid only
    when AUTO is set for VIDEO on the menu.
    • This operation requires approximately 10 seconds. It may not function correctly with
    some input signals.
    BLANK
    ON/OFFSet/Clear Blank Mode:Press the BLANK button. No image is displayed in
    the Blank mode. The screen color is as set in BLANK on the Image menu.
    MENU
    ON/OFF (
    *)
    Menu Display Start/Stop:Press the MENU button.• The menu display is terminated automatically after approximately 10 seconds of
    inactivity.
    MENU
    SELECT
    Select Menu Type:Press the MENU SELECT button. Allows the user to
    select the normal menu or the single menu. Only the selected item is
    displayed on the single menu, and other items are displayed with the  and
    buttons as with the normal menu.
    • Valid only when the Setup menu is used. Push the MENU SELECT button after
    selecting items such as BRIGHTNESS.
    • The MENU SELECT button may operate as the mouse control button. Refer to
    page 4.
    Normal menu Single menu
    KEYSTONE
    (
    *)Set / Clear KEYSTONE Mode :Press the KEYSTONE  button.
    Adjust KEYSTONE :Press the / button.
    ENGLISH-11
    ENGLISH
    ENGLISH-11
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Items indicated by (*) may be used from the control panel.
    Table 3. Basic Operation (continued)
    CONTRAST-2
    BRIGHT
    CONTRAST
    V POSIT
    H POSIT
    H PHASE
    H SIZE
    COLOR BAL R
    COLOR BAL B
    ASPECT0
    -2
    +1 
    0
    0 100
    100
    800SETUP INPUT OPT.IMAGE(MENU SELECT) 
    						
    							ENGLISH-12ENGLISH-12
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Setup MenuThe following adjustments and settings are possible when SETUP is selected at the top of the menu. Part of the
    Setup menu differs between RGB input and video input. Select an item with the  and buttons, and start
    operation. Use the Single menu to reduce menu size (see Table 3, MENU SELECT).
    VIDEO/S-VIDEOCOMPONENT
    RGB
    BRIGHT
    CONTRAST
    V POSIT
    H POSIT
    H PHASE
    H SIZE
    COLOR BAL R
    COLOR BAL B
    ASPECT0
    -2
    +1 
    0
    0 100
    100
    800SETUP INPUT OPT.IMAGEBRIGHT
    CONTRAST
    SHARPNESS
    COLOR
    TINT
    COLOR BAL  R
    COLOR BAL  B
    ASPECT0
    +1
    +1
    0
    0
    0
    0SETUP INPUT OPT.IMAGEBRIGHT
    CONTRAST
    COLOR
    H PHASE
    COLOR BAL  R
    COLOR BAL  B
    ASPECT0
    +1
    +1
    0
    0
    0SETUP INPUT OPT.IMAGE
    Table 4. Setup Menu
    ItemDescriptionRGBVIDEO
    S-VIDEOCOMPONENT
    480i
    575i
    480P720P
    1080i
    BRIGHTDark ↔Light✔✔✔✔
    CONTRASTWeak ↔Strong✔✔✔✔
    V POSITDown ↔Up✔---
    H POSITLeft ↔Right✔---
    H PHASELeft ↔Right
    • Adjust to eliminate flicker.✔-✔✔
    H SIZE
    Small ↔Large• The image may not be displayed correctly if the horizontal
    size is excessive. In such cases, press the RESET button,
    and initialize the horizontal size.✔---
    SHARPNESSSoft ↔Clear-✔--
    COLORLight ↔Dark-✔✔✔
    TINTRed ↔Green• Valid only when NTSC or NTSC 4.43 signal is received.-✔--
    COLOR BAL RLight ↔Dark✔✔✔✔
    COLOR BAL BLight ↔Dark✔✔✔✔
    ASPECT
    Select Image Aspect Ratio :
    4:3[ ] 
    ↔16:9[ ]
    Select Position of Image:
    Press the  button while 16:9[]
    is selected.
    Center
    →Down →Up (→Center )
    ✔--✔
    Select Image Aspect Ratio:
    4:3[ ]
    ↔16:9[ ]↔4:3small[ ]
    Select Position of Image :
    Press the  button 
    while 16:9[ ] / 4:3 small[ ] is selected.
    Center
    →Down→Up (→Center )• 4:3 small may not be displayed correctly with some input
    signals.
    -✔✔- 
    						
    							ENGLISH-13
    ENGLISH
    ENGLISH-13
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Input MenuThe following functions are available when INPUT is selected on the
    menu. Select an item with the and buttons, and start or stop
    operation with the and buttons. The function indicated (**) are
    effective on video input mode only, not on RGB input mode.
    Table 5. Input Menu
    EXECUTE
    CANCELAUTO
    RGB
    VIDEO
    HDTV SETUP INPUT OPT.IMAGE
    ItemDescription
    AUTO
    Automatic Adjustment at RGB Input: Select the EXECUTE with the
    button.Horizontal position (H.POSIT), vertical position (V.POSIT), clock
    phase (H.PHASE), and horizontal size (H.SIZE) are automatically adjusted.
    Use with the window at maximum size in the application display.
    Automatic Adjustment at Video Input: Select the 
    EXECUTEwith the 
    button. A signal type appropriate for the input signal is selected
    automatically. Valid only when AUTO is set for VIDEO on the menu.
    • This operation requires approximately 10 seconds. It may not function correctly with
    some input signals. Pressing the AUTO button in this case may correct this problem.
    • This function is the same as for the AUTO function in Basic operation.
    RGB
    Displays RGB Input Frequency:Displays the horizontal and vertical sync
    signal frequencies for RGB input.
    • Valid only at RGB input.
    VIDEO (**)
    Select Video Signal Type:Select the signal type with the  and 
    buttons. Select NTSC, PAL, SECAM, NTSC4.43, M-PAL, or N-PAL as
    appropriate for the input signal. The selection of AUTO enables and
    executes the function AUTO (Automatic Adjustment at Video Input), except
    for the N-PAL input.
    • Use this function when the image becomes unstable (eg. the image becomes
    irregular, or lacks color) at VIDEO/S-VIDEO input.
    • Automatic Adjustment requires approximately 10 seconds. It may not function
    correctly with some input signals. Pressing the AUTO button in this case may correct
    this problem except for the N-PAL input.
    • For the COMPONENT VIDEO input, this function is not effective and the signal type
    is distinguished automatically. 
    HDTV
    Select HDTV mode:Select the 1035i mode or 1080i mode suitable for the
    input signal with the  /  button.
    • When the selected HDTV mode is incompatible with the input signal, the image
    may be incorrect (eg. the display position or color is incorrect). 
    						
    							ENGLISH-14ENGLISH-14
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Image Menu
    The following adjustments and settings are available when IMAGE is
    selected on the menu. Select an item with the and buttons, and 
    start or stop operation with the and buttons.
    Table 6. Image Menu
    BLANK
    MIRROR
    START UP
    GAMMA
    COLOR TEMP
    SETUP INPUT OPT.IMAGE
    ItemDescription
    BLANKSelect Blank Screen Color:Select color with the  /  button.• The image is cleared and the entire screen is displayed in the selected color, when
    BLANK mode is set with BLANK ON, or when there is no signal for 5 minutes.
    MIRRORSelect Mirror Status:Select mirror status with  /  button.
    START UP
    Setup Initial Screen Display:Select TURN ON with the  button.
    Clear Initial Screen Display:Select TURN OFF with the  button.
    • Note that if TURN OFF is selected the blank screen is displayed in blue when there
    is no signal.
    GAMMASelect Gamma mode:Select the gamma mode with the  /  button.
    NORMAL 
    ↔CINEMA ↔DYNAMIC
    COLOR
    TEMPSelect Color Temperature:
    Select the color temperature mode with the  /  button.
    NORMAL 
    ↔LOW 
    						
    							ENGLISH-15
    ENGLISH
    ENGLISH-15
    O O O O
    P P P P
    E E E E
    R R R R
    A A A A
    T T T T
    I I I I
    O O O O
    N N N N
    S S S S
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Options Menu
    The following adjustments and settings are available when OPT. is
    selected on the menu. Select an item with the and buttons, and
    start or stop operation with the  and buttons. 
    Table 7. Options Menu
    VOLUMEMENU COLORLANGUAGE
    AUTO OFF
    SYNC ON G
    WHISPER16
    SETUP INPUT OPT.IMAGE
    ItemDescription
    VOLUMEReduce ↔Increase 
    MENU COLORSelect Menu Background Color:Select with the  /  button.
    LANGUAGESelect Menu Display Language:Select with the  /  button.
    AUTO OFF
    Set AUTO OFF:Set 1~99 minutes with the  /  button. The system
    automatically enters the standby mode when a signal is not received for
    the set time.
    Clear AUTO OFF:Select STOP (0 min.) with the  button. When
    STOP is selected the system does not enter the standby mode even if
    no signal is received.
    SYNC ON G
    SYNC ON G Valid:Select TURN ON with the  button.
    SYNC ON G Invalid:Select TURN OFF with the  button.
    • May not be displayed correctly with some input signals when SYNC ON G is
    valid. In such cases, remove the signal connector so that no signal is received,
    set SYNC ON G to invalid, and reconnect the signal.
    WHISPER
    Set / Crear WHISPER Mode: Press the  /  button.  When the
    WHISPER is selected, the WHISPER mode is active. In the WHISPER
    mode, acoustic noise level from the unit is reduced, and brightness level
    on screen is a little lower. 
    						
    							ENGLISH-16
    O
    O
    O
    O
    P
    P
    P
    P
    E
    E
    E
    E
    R
    R
    R
    R
    A
    A
    A
    A
    T
    T
    T
    T
    I
    I
    I
    I
    O
    O
    O
    O
    N
    N
    N
    N
    S
    S
    S
    S
     
     
     
     
    (
    (
    (
    (
    c
    c
    c
    c
    o
    o
    o
    o
    n
    n
    n
    n
    t
    t
    t
    t
    i
    i
    i
    i
    n
    n
    n
    n
    u
    u
    u
    u
    e
    e
    e
    e
    d
    d
    d
    d
    )
    )
    )
    )
    No Signal MenuThe same adjustments and settings are available with the Image and
    Options menus when the MENU button is pressed during display of the
    “NO INPUT IS DETECTED ON ***” or “SYNC IS OUT OF RANGE
    ON ***” message while no signal is received.Select an item with the
    and buttons, and start or stop operation with the and buttons.
    Table 8. No Signal Menu
    VOLUME
    BLANK
    MIRROR
    START UP
    MENU COLORLANGUAGE AUTO OFF
    SYNC ON G WHISPER 16
    ItemDescription
    VOLUME
    Reduce ↔Increase • When this function is used, audio input is automatically switched t\
    o video. The
    audio input can be switched by moving the DISK PAD left and right during\
     the
    display of the volume adjustment bar. The volume adjustment bar is displ\
    ayed by
    pressing VOLUME  /  button.
    BLANK
    Select Blank Screen Color:
    Select the color with the  /  button.• When the blank mode is set with BLANK ON, by absence of a signal, o\
    r by
    input of a non-standard signal, the image is cleared and the complete sc\
    reen is
    displayed in the selected color.
    MIRRORSelect Mirror Status:Select the mirror status with the  /  button.
    START UP
    Setup Initial Screen Display: Select the TURN ON with the  button.
    Clear Initial Screen Display: Select the TURN OFF with the  button.
    • Note that if TURN OFF is selected the blank screen is displayed in \
    blue when
    there is no signal.
    MENU COLORSelect Menu Background Color: Select the color with the  / 
    button.
    LANGUAGESelect Menu Display Language: Select the language with the  / 
    button.
    AUTO OFF
    Set AUTO OFF: Set 1~99 minutes with the  /  button. The system
    automatically enters the standby mode when a signal is not received for
    the set time.
    Clear AUTO OFF: Select the STOP (0 min.) with the  button. When
    the STOP is selected the system does not enter the standby mode even
    if no signal is received.
    SYNC ON G
    SYNC ON G Valid: Select the TURN ON with the  button.
    SYNC ON G Invalid: Select the TURN OFF with the  button.
    • May not be displayed correctly with some input signals when the SYN\
    C ON G is
    valid. In such cases, remove the signal connector so that no signal is r\
    eceived,
    set the SYNC ON G to invalid, and reconnect the signal.
    WHISPER
    Set / Crear WHISPER Mode:  Press the  /  button.  When the
    WHISPER is selected, the WHISPER mode is active. In the WHISPER
    mode, acoustic moise level from the unit is reduced, and brightness
    level on screen is a little lower. 
    						
    							ENGLISH-17
    ENGLISH
    MAINTENANCE MAINTENANCE
    Lamp
    HIGH VOLTAGE
    HIGH TEMPERATURE
    HIGH PRESSURE
    Contact your dealer before replacing the lamp.
    For the optional lamp, see the item “ACCESSORIES” of P.24.
    Before replacing the lamp, switch power OFF, remove the power cord from the power outlet, and
    wait approximately 45 minutes until the lamp has cooled. The lamp may explode if handled at high
    temperatures.
    Lamp Life
    Projector lamps have a finite life. The image will become darker, and hues will become weaker,
    after a lamp has been used for a long period of time. 
    Replace the lamp if the LAMP indicator is red, or the CHANGE THE LAMP message appears
    when the projector is switched ON. See Table 9 of P.20 and Table 10 of P.21.
    •The LAMP indicator is also red when the lamp unit reaches high temperature. Before
    replacing the lamp, switch power OFF, wait approximately 20 minutes, and switch power ON again.
    If the LAMP indicator is still red, replace the lamp.NOTE
    WARNING• For disposal of used lamp, treat
    according to the instruction of community
    authorities.
    • Since the lamp is made of glass, do not apply shock
    to it and do not scratch it.
    • Also, do not use old lamp. This could also cause
    explosion of the lamp.
    • Premature lamp failure MAY be caused by an
    electronic component in the projector and not
    necessarily the lamp. If unsure contact your local
    service center.
    • If it is probable that the lamp has exploded (explosive
    sound is heard), disconnect the power plug from the
    power outlet and ask your dealer to replace lamp. The
    lamp is covered by front glass, but in rare cases, the
    reflector and the inside of the projector may be
    damaged by scattered broken pieces of glass, and
    broken pieces could cause injury when being handled.
    • Do not use the projector with the lamp cover removed.
    Lamp
    Front
    glass Reflector 
    						
    							ENGLISH-18ENGLISH-18
    M M M M
    A A A A
    I I I I
    N N N N
    T T T T
    E E E E
    N N N N
    A A A A
    N N N N
    C C C C
    E E E E
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Replacing the Lamp
    1. Switch the projector OFF, remove the power cord from the
    power outlet, and wait at least 45 minutes for the unit to cool.
    2. Prepare a new lamp.
    3. Check that the projector has cooled sufficiently, and gently
    turn it upside down.
    4. Loosen the two screws as shown in the diagram, and remove
    the lamp cover.
    5. Loosen the three screws, and gently remove the lamp while
    holding the grips. Touching the inside of the lamp case may
    result in uneven coloring.
    6. Install the new lamp and tighten the three screws firmly.
    Also steadily push the opposite side of the screwed lamp into
    the unit.
    7. Replace the lamp cover in position and tighten the  two
    screws firmly.
    8. Gently turn the projector right-side up.
    Resetting the Lamp Timer
    Reset the lamp timer after replacing the lamp. When the lamp has been replaced after the LAMP
    indicator is red, or the CHANGE THE LAMP message is displayed, complete the following
    operation within ten minutes of switching power ON. The power will be turned off automatically in
    over 10 minutes.
    1. Switch power ON, and press the RESET button, for approximately three seconds. The ‘LAMP
    xxxx hr’ message will appear on the lamp timer on the bottom of the screen.
    2. Press the MENU button on the remote control transmitter, or the RESET button on the control
    panel, while the lamp timer is displayed. The ‘LAMP xxxx 
    →0 CANCEL’ message will
    then appear.
    3. Press the  and select 0, and wait until the timer display is cleared.
    •Do not reset the lamp timer without replacing the lamp. Reset the lamp timer always
    when replacing the lamp. The message functions will not operate  properly if the lamp timer is not
    reset correctly.NOTE
    CAUTION• Ensure that screws are tightened
    properly. Screws not tightened fully may result
    in injury or accidents.
    • Do not use the projector with the lamp cover
    removed. 
    						
    							ENGLISH-19
    ENGLISH
    ENGLISH-19
    M M M M
    A A A A
    I I I I
    N N N N
    T T T T
    E E E E
    N N N N
    A A A A
    N N N N
    C C C C
    E E E E
           
    ( ( ( (
    c c c c
    o o o o
    n n n n
    t t t t
    i i i i
    n n n n
    u u u u
    e e e e
    d d d d
    ) ) ) )
    Air Filter
    Cleaning the air Filter
    The air filter should be cleaned as described below at intervals of approximately 100 hours.
    1. Switch the projector power supply OFF, and remove the power cord from the power outlet.
    2. Clean the air filter with a vacuum cleaner.
    Other Maintenance
    Maintenance Inside the Equipment
    For safety reasons, ensure that the equipment is cleaned and checked by the dealer once every two
    years. Maintaining the equipment by yourself is dangerous.
    Cleaning the Lens
    Gently wipe the lens with lens cleaning paper. Do not touch the lens with your hands.
    Cleaning the Cabinet and Remote control transmitter
    Gently wipe with a soft cloth. If dirt and stains etc. are not easily removed, use a soft cloth
    dampened with water, or water and a neutral detergent, and wipe dry with a soft, dry cloth.
    CAUTION• Switch power OFF and remove the power cord from the power
    outlet before beginning maintenance work. Please read the “Product Safety
    Guide” thoroughly to ensure that maintenance is performed correctly.
    • Do not use detergents or chemicals other than those noted above (e.g. benzene
    or thinners).
    • Do not use cleaning sprays.
    • Do not rub with hard materials, or tap the equipment.
    CAUTION• Switch power OFF and remove the power cord from the power
    outlet before beginning maintenance work. Please read the “Product Safety
    Guide” thoroughly to ensure that maintenance is performed correctly.
    • Replace the air filter if contamination cannot be removed, or if it is damaged.
    Contact your dealer in such case. For the optional air filter, see the item
    “ACCESSORIES” of P.24. 
    • Do not use the equipment with the air filter removed.
    • When the air filter is clogged with dust etc. the power supply is switched OFF
    automatically to prevent the temperature rising inside the projector.
    Replacing the Air Filter
    Replace the air filter if contamination cannot be removed, or if it is damaged.
    1. Remove the filter cover.
    2. Remove the old filter.
    3. Set the new filter and the filter cover. 
    						
    							ENGLISH-20ENGLISH-20
    TROUBLESHOOTING
    TROUBLESHOOTING
    Service Information
    For product information,product assistance,service information,or to ord\
    er accessories,please call:
    In U.S.or Canada :1-800-328-1371
    In other locations,contact your local 3M sales office.
    OSD Message
    The messages as described below may appear on the screen at power ON. Ta\
    ke the appropriate
    measures when such messages appears.
    Table 9. OSD Message
    MessageContents
    CHANGE THE LAMP
    AFTER REPLACING LAMP, RESET THE LAMP TIME. (
    *1)
    The usage time of lamp will be reaching 2000 hr
    shortly.	
    
    It is recommended to replace the lamp soon.  Prepare a
    new lamp as a replacement.  
    CHANGE THE LAMP
    AFTER REPLACING LAMP, RESET THE LAMP TIME.
    THE POWER WILL TURN OFF AFTER 
    **hr. (*1)
    The usage time of lamp will be reaching 2000 hr shortly.
    It is recommended to replace the lamp within * *
    hours.	
    
    It might be happened that the lamp is cut off before * * hr
    by any chance.  Power will be switched OFF
    automatically in * * hours.  Replace the lamp as shown in
    P.17~18 “Lamp”.  Always reset the lamp timer after
    replacing the lamp. 
    CHANGE THE LAMP
    AFTER REPLACING LAMP, RESET THE LAMP TIME. THE POWER WILL  TURN OFF
    AFTER 0 hr.The usage time of lamp is about to reach.  Power will be
    switched OFF in a few minutes. 	
    
    Switch power OFF immediately and replace the lamp as
    shown in P.17 ~18 “Lamp”.  Always reset the lamp timer
    after replacing the lamp. 
    NO INPUT IS DETECTED
    ON ***No input signal found.
    Check signal input connections and signal sources.
    SYNC IS OUT OF RANGE ON ***
    The horizontal or vertical frequency of the input signal is
    not within the specified range.
    Check the specifications of the equipment and the signal
    source.
    (*1) This message is cleared automatically after approximately three m\
    inutes, and
    appears every time power is switched ON.
    (*2) The unit has a function to turn the power off which will be activ\