3M Dynatel 2273 Advanced Cable and Fault Locator User Manual
Here you can view all the pages of manual 3M Dynatel 2273 Advanced Cable and Fault Locator User Manual. The 3M manuals for Locator are available online for free. You can easily download all the documents as PDF.
Page 1
September 1999 78-8097-6517-1-B Dynatel™ 2273 Advanced Cable and Fault Locator Operators Manual
Page 2
TABLE OF CONTENTS Introduction ............................................................................... 2 Installing or Replacing the Batteries ........................................ 2 Initial Receiver Configuration .................................................. 3 Receiver Battery Test ................................................................ 3 Transmitter Battery Test ........................................................... 4 Using External DC Power and 5 Watt Output...
Page 3
INTRODUCTION The 3M™ Dynatel™ 2273 Advanced Cable and Fault Locator consists of a Transmitter and a Receiver for locating buried cables or Active Duct Probes (sondes). It also measures and pinpoints sheath faults in buried cables and conductor faults in aerial cables. The Transmitter provides four frequencies to accommodate varying factors such as distance, cable type, or soil conditions. If desired, all four frequencies may be transmitted at once. The Transmitter also provides a separate Tone function...
Page 4
INITIAL RECEIVER CONFIGURATION Display depth units (inches, feet and inches, or centimeters) may be changed while holding and pressing . For each press, one of three units will display. To change the passive Power frequency, press and hold then press to toggle between 50 or 60 Hz as displayed in the lower left corner of the display. To change the Null bar graph display mode, press and hold then press to toggle between normal Null bar graph display (Null flag will flash) and inverse Null bar...
Page 5
TRANSMITTER BATTERY TEST To test the Batteries, press and hold . Listen to the tone and watch the display. • solid tone and OK indicates batteries good; • beeping tone and LO indicates batteries low; • no tone and - - indicates replace batteries. Note: The battery test indicates battery condition for normal output levels. If the unit resets when the high output level is selected, use the normal output level or replace the batteries. USING EXTERNAL DC POWER AND 5 WATT OUTPUT If the unit has the...
Page 6
LOCATING A BURIED CABLE Transmitter Setup Note: Key descriptions can be found inside the Transmitter lid. Perform a battery test and then connect the Transmitter using one of the three methods below to put tracing signal on a cable. DANGER! Voltage greater than 240 volts will damage equipment and cause personal injury and death. Make all direct test connections before turning on the Transmitter. Then activate the Transmitter in the Ohms mode and check the display for voltage readings. Follow standard...
Page 7
Make sure the Transmitter is off. Plug the direct connect cable into the front panel jack. Connect the Black clip to the ground rod. Place the ground rod in the earth perpendicular to the suspected cable path. If necessary, extend the black lead with the Ground Extension Cable. Next, remove the ground bonding and attach the Red clip to the shield. Press to turn the Transmitter on in the Ohms mode . It will measure the continuity of the cable under test. The results are displayed in ohms...
Page 8
Press to select Trace mode. Press again to select one or all of the four frequencies. The display will alternate between displaying the selected frequency and the output signal current. It is best to choose the lowest frequency for direct connect with far-end ground and a high frequency for direct connect with no far-end ground. Press to select high output level for longer tracing distances and deep cables. Transmitter setup is finished, now go to LOCATING A BURIED CABLE - R ECEIVER SETUP (Page...
Page 9
Dyna-Coupler Method Cable Path Connect the Dyna-Coupler to the Transmitter front panel jack using the coupler cable. Clamp the Dyna-Coupler around the cable below any bonds just before the cable enters the earth. The jaws of the coupler must fully close. Press to turn Transmitter on. Press again to select 8 kHz, 33kHz, or 200 kHz. Select high output level by pressing . Transmitter setup is finished, now go to LOCATING A BURIED CABLE - Receiver Setup (Page 10). Page 8
Page 10
Induction Method Place the transmitter on the ground over the target cable with the lid hinge in line with the cable path. Press to turn the Transmitter on. Press again to select either 33 kHz or 200 kHz. For greater tracing range, select high output level by pressing . Note: If the Receiver is less than 50 feet from the Transmitter, it can pick up signal through the air. For best results, keep the Receiver away from the Transmitter by at least that distance. Transmitter setup is finished, now go...