3M 7600 EMS Caution Tape Brochure
Have a look at the manual 3M 7600 EMS Caution Tape Brochure online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 307 3M manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
3M Electrical Markets Division 3M™ Electronic Marking System (EMS) Caution Tape 7600 Series 3M ™ Dynatel™ Cable/Pipe/Fault/EMS Tape Locators 7000 Series Locate Plastic Pipe & Conduit
A Revolutionary Approach to Locating Plastic Pipes/Conduit Path 3M has over 30 years experience developing new and innovative solutions for locating buried assets. 3M pioneered electronic marker technology with EMS markers and programmable ID markers and continues to set the standard for innovation with its newest path marking technology. Now, 3M has developed an effective way to locate the path of underground plastic pipes and conduits, eliminating the need, problems and costs associated with tracer wire and test stations. 3M™ EMS (Electronic Marking System) Caution Tape 7600 Series 3M ™ Dynatel™ Cable/Pipe/Fault/EMS Tape Locators 7000 Series Introducing 3M’s Next Generation of Underground Infrastructure Asset Management System Benefits • Eliminates need to install tracer wire • No access points or connections required • Locate without the need of a transmitter • Unique identification for each utility type • Low installed costs • Tape does not provide a path for lightning • Signal path maintained even if the tape is cut or damaged • Product design life — 50 years
3M™ Electronic Marking System ( EMS) Caution Tape 7600 Series 3M ™ ID Ball Markers EMS Caution Tape for Path Marking 3M™ Electronic Marking System Caution Tape uses a new EMS marker technology embedded into a caution tape for installation near or above the buried facility and helps provide continuous path location. When energized using a 3M ™ Dynatel™ Locator 7000 Series, the markers are activated. The markers require no batteries, and there is no need to hook up an external transmitter or search for access points. The markers work independently, so even if a section of caution tape is cut or removed, the other markers on the tape would continue to provide accurate location. Each version of 3M ™ EMS Caution Tape is tuned to a frequency specific to the path of that utility (gas, telco, or wastewater) and can be buried up to two feet (.76 m). EMS Electronic Markers for Point Marking 3M™ EMS Caution Tape for path marking is a perfect complement to 3M’s existing line of EMS passive and ID markers (Near Surface, Ball and Full Range markers) which are used for marking points of interest, such as splices, service drops, valves, etc. ID markers can be programmed to include specific information such as facility data, type of application, placement date and other important details. 3M™ Electronic Marker Specifications Telephone PowerCAT VGeneral Purpose WaterWastewater GasRead Range* Colororangeredblack/orangepurplebluegreenyellow n/a ID Ball Marker 1421-XR/ID 1422-XR/ID1427-XR/ID1428-XR/ID1423-XR/ID1424-XR/ID1425-XR/ID5 ft. (1.5 m) ID Near-Surface1432-XR/ID 1433-XR/ID1437-XR/ID1438-XR/ID1434-XR/ID1435-XR/ID1436-XR/ID3 ft. (0.9 m) ID Full-Range1250-XR/ID 1251-XR/ID N/A1248-XR/ID 1252-XR/ID1253-XR/ID1254-XR/ID8 ft. (2.4 m) Non-ID Ball Marker XR1401-XR 1402-XR1407-XR1408-XR1403-XR 1404-XR1405-XR6 ft. (1.8 m) Near-Surface Marker 1432 1433 N/AN/A1434 143514363 ft. (0.9 m) Mini-Marker 1255 1256 N/AN/A1257 125812597 ft. (2.1 m) Full-Range 1250 1251 N/AN/A1252 125312549 ft. (2.7 m) *Read range specifies maximum distance from locator probe using 3M™ Dynatel™ Locator 7000 Series. Read range may vary on export models–refer to product bulletins. Some countries do not allow all marker operating frequencies.
3M™ EMS Caution Tape 7600 Series Specifications Description:6 Mil PE film with 3M Markers for locating Part Number: 7600 Series Tape Material: Polyethylene Color(s): Yellow, Orange, Green Gauge(s): 6 Mil (+/- 10%) Roll Width(s): 6" (0.15 m) Roll Length: 1,312 ft. (400 m) Density*: .920 g/cc (6.0 Mil) Tensile at Break (psi) / (with markers attached)*: MD 1307 (+/- 5%) TD 377 (+/- 5%) Elongation (%)*: MD 7.8 TD 12.7 Tear Strength (g)*: MD 440 TD 1200 Physical Specifications: Weight(s): 22 lbs. @ 4" wide 44 lbs. @ 6" wide Spool size: 6" wide 19.5 in. (.5 m) dia. x 12 in. (.3 m) Spool hole: 3.0 dia in Environmental Specifications: Operating temperature -4° F to 122° F (-20° C to 50° C) Storage temperature -4° F to 149° F (-20° C to 65° C) Compatibility: 3M ™ Dynatel™ 7400 and 7500 Series Locators Maximum Burial Depth**: 7600 Series Tape 2.0 ft. (.61 m) (maximum)** * Based on average production ** Using 3M™ Dynatel™ 7000 Series Locators 3M™ Electronic Marking System ( EMS) Caution Tape 7600 Series Ordering Information Product Number Product Description 3M ID 7605-XR-CT-GAS EMS Tape 6", 400 m roll, English 80-6116-1196-5 7604-XR-CT-WW EMS Tape 6", 400 m roll, English 80-6116-1198-1 7601-XR-CT-TEL EMS Tape 6", 400 m roll, English 80-6116-1195-7
3M™ Dynatel™ Cable/Pipe/Fault/EMS Locator 7500 Series 3M ™ Dynatel™ Cable/ Pipe/ Fault / EMS Locator 7500 Series 3M™ Dynatel™ Locators 7000 Series Marker Tape/Locator 7420 Based on existing Dynatel technology platform, the new 7420 locator will\ allow the user to locate EMS Caution Tape and existing electronic markers (balls, near- surface, full range, etc.). In addition, the locator will read/write to\ 3M ID markers. It is as easy as selecting “path” marker locating for EMS Caution \ Tape or “ID/EMS” for point marker locating. The push of one button will provide the depth to any of the underground marking solutions. Pipe/Cable/EMS Locators 7550-ID Pipe/Cable/Fault/EMS Locators 7573-ID 3M™ Dynatel™ locators 7500 series offer a broad feature set with advanced digital processing and simple interfaces with precision locating capabilities. The new 7500 series locators will allow the user to locate EMS Caution Tape and existing electronic markers (balls, near-surface, full range, etc.). In addition, all 7500 series locators will read/write to 3M ID markers. All 7500 series locators offer six active frequencies and transmitter output options in 3, 5 or 12 watts providing a solution for virtually all challenging applications encountered in the field. As with all 3M Dynatel Cable/Pipe Locators, the 7500 series provides accurate pipe, cable, or Sonde depth measurements, giving a digital readout in feet and inches, or centimeters (user-selectable). All 7500 series locators and fault finders are also compatible with select GPS/GIS field mapping instruments for real time mapping of electronic markers or pipe and cable facilities. Other user friendly features include the ability to enable or disable receiver frequencies and the ability to select audio sounds in the simple menu driven interface. A Reputation of Excellence When you choose a quality 3M™ Dynatel™ Locator, you get outstanding performance and reliability, along with toll-free technical phone support and a service center dedicated to excellence. Our service center provides calibration, repair\ , upgrades and modifications for safety, performance and reliability. Product Features • 6 active frequencies for direct connect • 4 induction frequencies with maximum allowed output power • Trace view mapping display • Push button depth to all underground markers (passive and ID) • Receiver rechargeable battery kit • All frequency mode in direct connect (4 simultaneously) • Automatic impedance matching • Ohm meter with high voltage detection • Rugged, industrial temperature range • 240VAC output protection New features in the 3M ™ Dynatel™ 7500 Series Locators include EMS Caution Tape Locating and EMS alert which allows the user to locate EMS Caution Tape and at the same time be alerted to electronic markers of the same utility.
Cable/Pipe Locate Earth Return Fault Locate 3M Passive/ID & Caution Tape Marker Locate Transmitter Output Direct Connect Cable - large clips Direct Connect Cable - small clips Coupler Size Coupler Cable 2200RB Rechargeable Battery A-Frame/A-Frame Cable Ground Rod Carrying Bag Cigarette Lighter Adapter Stock No.US Version Locators 8066113-8923-27420EMS Marker/Tape Locator/Read/Write 80-6300-0271-7 7550-ID/U3Pipe/Cable/EMS Lctr Util 4.5" Cplr 3W 3W 4.5" 80-6300-0272-5 7550-ID/U5Pipe/Cable/EMS Lctr Util 4.5" Cplr 5W 5W 4.5" 80-6300-0273-3 7550-ID/U12Pipe/Cable/EMS Lctr Util 4.5" Cplr 12W 12W 4.5" 80-6300-0274-1 7550-ID/5-NAPipe/Cable/EMS Lctr 5W (No accys) 5W 80-6300-0275-8 7573-ID/U3Pipe/Cable/Fault/EMS Lctr Util 4.5" Cplr 3W 3W 4.5" 80-6300-0276-6 7573-ID/U5Pipe/Cable/Fault/EMS Lctr Util 4.5" Cplr 5W 5W 4.5" 80-6300-0277-4 7573-ID/U12Pipe/Cable/Fault/EMS Lctr Util 4.5" Cplr 12W 12W 4.5" 80-6300-0278-2 7573-ID/C3Cable/Pipe/Fault/EMS Lctr Com 3" Cplr 3W 3W 3" 80-6300-0279-0 7573-ID/C5Cable/Pipe/Fault/EMS Lctr Com 3" Cplr 5W 5W 3" 80-6300-0280-8 7573-ID/C12Cable/Pipe/Fault/EMS Lctr Com 3" Cplr 12W 12W 3" 80-6300-0281-6 7573-ID/5-NAPipe/Cable/Fault/EMS Lctr 5W (No accys) 5W 80-6300-0324-4 7550-ID/URCable/Pipe/EMS Receiver Only 80-6300-0326-9 7573-ID/URCable/Pipe/Fault/EMS Receiver Only Stock No. Export Version Locators 80-6113-8924-07420-EEMS Marker/Tape Loctator/Read/Write 80-6300-0295-6 7550E-ID/CU5Cable/Pipe/EMS Lctr Com/Util 3" Cplr 5W 5W 3" 80-6300-0296-4 7550E-ID/CU12Cable/Pipe/EMS Lctr Com/Util 3" Cplr 12W 12W 3" 80-6300-0297-2 7573E-ID/CU5Cable/Pipe/Fault/EMS Lctr Com/Util 3" Cplr 5W 5W 3" 80-6300-0298-0 7573E-ID/CU12Cable/Pipe/Fault/EMS Lctr Com/Util 3" Cplr 12W 12W 3" 80-6300-0325-1 7550E-ID/RCable/Pipe/EMS Receiver Only (Export) 80-6300-0327-7 7573E-ID/RCable/Pipe/Fault/EMS Receiver Only (Export) 3M™ Dynatel™ Locators and Fault finders 7500 Series Ordering Information
Optional/Replacement Accessories Stock NumberProduct Number Product Description 80610074686 3001 Dyna-Coupler 3-Inch 80610764716 3019 Cable Locator Coupler Accessory Kit 3" 80611325830 4001 Dyna-Coupler 4.5 Inch 80611335201 4519 Locator Coupler Accessory Kit - 4.5" 80610411185 1196 6" Dyna-Coupler W/Pouch 80611312499 1196/C 6" Dyna-Coupler W/Pouch & 9011 Coupler Cable 80610598130 2876 Large Clip Direct-Connect Trnsmtr Cable for Cable/Fault Locators 80610598668 2892 Small Clip Direct-Connect Trnsmtr Cable for Cable/Fault Locators 80610074850 9012 Direct Connect, 5-Foot Transmitter Cable, Telephone 80610074843 9011 Coupler Cable 80610126833 9043 Ground Extension Cable 12' 80611330368 2200M-USB USB To RS232 Converter For 2200M/1420 Locators 80610074777 3014 Earth Contact Frame 80610074942 9026 Earth Contact Frame Cable 80611146715 2200M/7000 Soft Carrying Bag For 2200M/2500/7000 Series 80611306517 2200/7000RB Rechargeable Battery for 5W & 12W Units Non-Spillable 80630002535 7000RB Rechargeable Battery Pack for 7000 Series Rcvr 80610126841 8006 Ground Rod 80610757785 3229 ADP 33 kHz Sonde for Use w/Cable/Fault Locators
3M™ Dynatel™ EMS Marker/Tape Locator 7420/7420E Product Specifications Physical Specifications: Locator Shipping BoxSize (H x W x D) IN (CM) 30" x 6.5" x 10.5" (76 x 17 x 27) Size (L x W x H) IN (CM) 33" x 17" x 12.5" (84 x 43 x 32) Weight (including batteries) 5 lb. (2.25 kg) 7 lb. (3.2 kg) Environmental Specifications: Operating temperature Storage temperature Regulatory Environmental Standard -4° F to 122° F (-20° C to 50° C) -4° F to 158° F (-20° C to 70° C) 7420 (FCC Part 15), 7420E (CE) IP54 Compatibility: 3M EMS/ID Markers 3M EMS 7600 Series Caution Tape All 3M markers (telephone, gas, communication, power, water, wastewater and general purpose) All 3M path marking caution tape (telephone, gas, wastewater) Range/Depth: Write Range 3M ID Markers: Near-Surface Ball Marker Full-Range 6 in. (15 cm) 12 in. (30 cm) 24 in. (61 cm) 7420 Read Range 3M ID Markers: (Telephone, Power, Gas, Water, Wastewater, Communications (CATV), General Purpose) 1 Near-Surface Ball Marker Full-Range3 ft. (0.9 m) 5 ft. (1.5 m) 8 ft. (2.4 m) 7420E Read 3M ID Markers: (Telephone, Gas, Wastewater, Water, Communications (CATV), General Purpose)* Near-Surface Ball Marker Full-Range 90 cm (36 in.) 1.5 m (60 in.) 2.4 m (94 in.) * Some countries do not allow all marker operating frequencies. Refer to the Operator's Manual for more information. Detection Depth 3M Passive Markers (no ID): Near-Surface Ball Marker Mid-Range Full-Range3 ft. (0.9 m) 6 ft. (1.8 m) 7 ft. (2.1 m) 9 ft. (2.75 m) Maximum Burial Depth 7600 Series Caution Tape Depth measurement accuracy 2.0 ft. (.61 m) +/- (10% + 5 cm) or +/- (10% + 2 in.) up to specified depth of mar\ ker or caution tape (Depth accuracy susceptible to high ambient noise conditions) ID Marker Memory Storage: Memory storage with date/time stamp Written marker records User defined ID templates Marker depth memory storage Read marker records 100 100 32 Five with date/time stamp Electrical Specifications: Power Battery life: Charging time Display Speaker Headphone jack Serial port Rechargeable battery pack (12V2R4A) 2 8 hours typical3 2.5 hours, with 90~240V AC adapter Large graphic high-contrast LCD with backlight 0.25 W Standard mini phone jack Standard RS232 serial with DB9 connector(RS232 to USB adapter cable included) Notes:1Some countries do not allow all marker operating frequencies. Refer to configuration section for 7420E instruction manual (Section 4A). 2 It’s recommended to use the rechargeable battery pack. However, a battery holder is provided for using 8-AA size Alkaline batteries for backup, which would have reduced battery life. 3The battery life is measured for the 12V2R4 rechargeable battery pack at 73°F/23°C, with 10% usage of the backlight and audio volume at medium level.
3M™ Dynatel™ Pipe/Cable/Fault/EMS Locator 7500 Series Product Specifications Physical Specifications: Locator Shipping BoxSize (H x W x D) IN (CM) 30” x 6.5” x 10.5” (76 x 17 x 27) Size (L x W x H) IN (CM) 33” x 17” x 12.5” (84 x 43 x 32)Weight (including batteries) 6.4 lb. (2.90 kg) 7 lb. (3.2 kg) Environmental Specifications: Operating temperature Storage temperature Regulatory Environmental Standard-4° F to 122° F (-20° C to 50° C) -4° F to 158° F (-20° C to 70° C) 7550 (FCC Part 15), 7550E (CE) 7573 (FCC Part 15), 7573E (CE) IP54 7500 Series Receiver Specifications Power Battery Life Charging Time Display Speaker Headphone jack Serial Port Rechargeable Li Ion battery pack (12V2R4A)1 8 hours typical2 2.5 hours typical, with 90~240V AC adapter Large graphic high-contrast LCD with backlight 0.25W Standard mini phone jack Standard RS232 serial with DB9 connector (RS232 to USB adapter cable included) Display LCD Gain ControlManual and Automatic Weight w/batteries 5.0 - 6.4 lbs. (2.3 - 2.9 kg) (model dependent) Cable/Pipe Depth Accuracy ±2% ± 3 in. (7.6 cm) for 0–60 in. (1.5 m) ±6% ± 3 in. (7.6 cm) for 60–120 in. (1.5–3.0 m) ±10% ± 3 in. (7.6 cm) for 120–180 in. (3.0 m–4.5 m) Cable/Pipe Depth Range 0–360 in. (0–914 cm) Locate Modes: Trace View Directional Peak Directional Null Special Peak Induction Peak Frequency Response: Active 7550/7573 577 Hz 1 kHz 8 kHz 33 kHz 82 kHz 200 kHz Active 7550E/7573E International 577 Hz 1 kHz 8 kHz 33 kHz 82 kHz 133 kHz Passive 31.5 kHz (CATV) 15 – 30 kHz (LF) Power 50 Hz, 5th and 9th harmonic of 50 Hz 60 Hz, 5th and 9th harmonic of 60 Hz (100 / 120 Hz) rectified power Auxiliary 512 Hz 560 Hz 640 Hz User Defined Frequencies Four
Marker Compatibility: 3M ™ EMS/ID Markers 3M™ EMS 7600 Series Caution Tape All 3M markers (telephone, gas, communication, power, water, wastewater and general purpose) All 3M path marking caution tape (telephone, gas, water, waste water) Write Range 3M ™ ID Markers: (Telephone,Power*, Gas, Water, Wastewater, Communications (CATV), General Purpose) Near-Surface Ball Marker Full-Range 6 in (15 cm) 12 in (30 cm) 24 in (61 cm) * The Power frequency is not supported for 7550E /7573E in write mode. 7550/7573 Read Range 3M™ ID Markers: (Telephone, Power, Gas, Water, Wastewater, Communications (CATV), General Purpose)* Near-Surface Ball Marker Full-Range 3 ft (0.9 m) 5 ft (1.5 m) 8 ft (2.4 m) 7550E/7573E Read Range 3M ™ ID Markers: (Telephone, Water, Gas, Wastewater, Communications (CATV), General Purpose)* Near-Surface Ball Marker Full-Range 90 cm (36 in) 1.5 m (60 in) 2.4 m ( 96 in) * Some countries do not allow all marker operating frequencies. Refer to Configuration Section for 7550E/7573E (Section 4A). Detection Depth for Passive Markers (no ID): Near-Surface Ball Marker Mid-Range Full-Range3 ft (0.9 m) 6 ft. (1.8 m) 7 ft. (2.1 m) 9 ft. (2.75 m) Maximum* Burial Depth 7600 Series CT-3 Tape Depth measurement accuracy 2.0 ft. (.61 m) +/- (10% + 5 cm) or +/- (10% + 2 in) up to specified depth of mark\ er or caution tape (Depth accuracy susceptible to high ambient noise conditions) Maximum Burial depth 2.5 \ ft (.7 m) ID Marker Memory Storage: Memory storage with date/time stamp Written marker records User defined ID templates Marker depth memory storage Read marker records 100 100 32 Five with date/time stamp Notes: 1. It’s recommended to use the rechargeable battery pack. However, a battery holder is provided for using 8-A A size Alkaline batteries for backup, which would have reduced battery life. 2. The battery life is specified for the 12V2R4 rechargeable battery pack at 73°F / 23°C, with 10 % usage of the backlight and audio volume at medium level. 7500 Series U Version 12-Watt Transmitter Specifications Item Specification Trace Mode 577 Hz 1 kHz 8 kHz 33 kHz 82 kHz 200 kHz Fault Mode (7573 models only) 10/20 Hz -Fault signal 577 Hz / 33 kHz -Trace signal. Tone Mode (7573 models only) 577 Hz and 200 kHz pulsing at 8 Hz Induction Mode 8 kHz 33 kHz 82 kHz 200 kHz Output Power (in Direct Connect mode) Normal setting: 0.5 W High setting: 3 W @ 577 Hz, 1 kHz, 8 kHz, 33 kHz; 1 W @ 82 kHz, 200 kHz Maximum setting: 12 W @ 577 Hz, 1 kHz, 8 kHz; 10 W @ 33 kHz; 1 W @ 82 kHz, 200 kHz Output Voltage (Maximum) 70 Vrms