Home > Anaheim > Stepper

Anaheim Stepper User Manuals

The manuals from this brand are divided to the category below. You can easily find what you need in a few seconds.
Show categories
Anaheim Stepper User Manuals
                                                    FEATURES DESCRIPTION
910 East Orangefair Ln.  Anaheim, CA 92801     Tel. (714) 992-6990     Fax. (714) 992-0471     www.anaheimautomation.com
DIMENSIONS
• Designed for OEM Applications
• Cost Effective Line Powered Driver
• No Power Supply Needed
• Outstanding Servo-Like Performance
• Smooth Microstepping Resolution
• Compact and Rugged Construction
• Compatible with NEMA 23, 34, and 42
Step Motors
MLP08641 - Line Powered Driver MLP08641 - Line Powered Driver
Would you like your step
motor to ramp...
                                            
                                                    #L010150February 2004
MLP08641 MLP08641MLP08641 MLP08641
MLP08641
High Performance Microstepping Driver High Performance Microstepping DriverHigh Performance Microstepping Driver High Performance Microstepping Driver
High Performance Microstepping Driver
User’s Guide User’s GuideUser’s Guide User’s Guide
User’s Guide
910 East Orangefair Lane, Anaheim, CA 92801
e-mail: [email protected](714) 992-6990  fax: (714) 992-0471
website: www.anaheimautomation.com
ANAHEIM AUTOMATION ANAHEIM...
                                            
                                                    March 2006
Addendum - MLP08641-01 Addendum - MLP08641-01Addendum - MLP08641-01 Addendum - MLP08641-01
Addendum - MLP08641-01
#L010219
This version of the MLP08641 has an additional opto-isoltaed output for notifying the user of a fault
condition. The output is on a 4 pin mini-fit jr. style connector and has two 24 inch leads for it. The wire
colors for the output are as follows:
Red/White - This is the collector of the optically isolated fault output. When a fault occurs, this
output will conduct current...
                                            
                                                    FEATURES DESCRIPTION
910 East Orangefair Ln.  Anaheim, CA 92801     Tel. (714) 992-6990     Fax. (714) 992-0471     www.anaheimautomation.com
DIMENSIONS
•  250 VAC Power Input
•  High Torque Output
•  Output Current 5.0 Amps Peak
•  200 to 12,800 steps/rev (1, 2, 5, 8, 10, 16, 32 and 64
   Selectable Step Operations)
•  Short Circuit Protection
•  Over-Temperature and Over-Voltage Shutdown
•  No Minimum Inductance
•  Optical Isolation
•  Motor ON/OFF input
If you’re looking for big time stepper...
                                            
                                                    #L010349December 2006
MLU05641
High Performance Microstepping Driver
User’s Guide
910 East Orangefair Lane, Anaheim, CA 92801
e-mail: [email protected](714) 992-6990  fax: (714) 992-0471
website: www.anaheimautomation.com
ANAHEIM AUTOMATION 
                                            
                                                    FEATURES DESCRIPTION
910 East Orangefair Ln.  Anaheim, CA 92801     Tel. (714) 992-6990     Fax. (714) 992-0471     www.anaheimautomation.com
DIMENSIONS
•  High Torque Output
•  Output Current 10.0 Amps Peak
•   200 to 12,800 steps/rev (1 , 2, 5, 8, 10, 16, 32 and 64
   Selectable Step Operations)
•  Short Circuit Protection
• Over-Temperature and Over-Voltage Shutdown
•  No Minimum Inductance
•  Optical Isolation
•  Motor ON/OFF input
If you’re looking for big time stepper
performance, the MLU10641 is...
                                            
                                                    #L010351December 2006
MLU10641
High Performance Microstepping Driver
User’s Guide
910 East Orangefair Lane, Anaheim, CA 92801
e-mail: [email protected](714) 992-6990  fax: (714) 992-0471
website: www.anaheimautomation.com
ANAHEIM AUTOMATION 
                                            
                                                          
4 Lead Wire Stepper Motor wiring configurations 
 
 
Connection Lead Wire Connection Lead Wire Color Phase 1 (A) Black Phase 3 (/A) Orange Phase 2 (B) Red 4 –Lead Bipolar Series 
MBC or MLP Series 
Phase 4 (/B) Yellow  
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
910 E. Orangefair Lane, Anaheim, CA 92801    Tel           (714) 992 - 6990  
Website: http:\\www.anaheimautomation.com       Fax    (714) 992 - 0471  
                                            
                                                          
8 Lead Wire Stepper Motor wiring configurations 
 
 
Connection Lead Wire Connection Lead Wire Color Phase 1 (A) Black Phase 3 (/A) Orange Phase 2 (B) Red Phase 4 (/B) Yellow Connect Wires with Wire 
Nut White/Black & White/Orange 4 –Lead Bipolar Series 
MBC or MLP Series 
Connect Wires with Wire 
Nut White/Red & White/Yellow Phase 1 (A) Black & White/Orange Phase 3 (/A) Orange & White/Black Phase 2 (B) Red & White/Yellow 4 –Lead Bipolar Parallel 
MBC or MLP Series 
Phase 4 (/B) Yellow & White/Red...
                                            
                                                    L010135 - Nema 34 High Torque Motor Comparison.doc910 E. Orangefair Lane
Anaheim, CA 92801
Tel (714) 992-6990
Fax (714) 992-0471
http://www.anaheimautomation.com
Nema 34 High Torque Motor Comparison
Anaheim
Automation
Part NumberPacific Scientific
Part NumberHolding
Torque
Bipolar
oz-inDynamic
Torque
Bipolar
oz-inRotor
Inertia
oz-in-sec2Length1 Piece
Price100 piece
price34R1xxS-LW8
N/A450360.01982.60”$137.00$95.9034N1xxS-LW8
N31HRFx-LNK-NS665500.02023.13”$216.00$151.2034R2xxS-LW8...
                                            
                                                    FEATURES DIMENSIONS
910 East Orangefair Ln.  Anaheim, CA 92801     Tel. (714) 992-6990     Fax. (714) 992-0471     www.anaheimautomation.com
DESCRIPTION
• Internal Index Count Switches
• Pulse Rates up to 14,792 Pulses per second
• CW and CCW Home, Hard and Soft Limit Inputs
• Adjustable Motion “Complete” Output
• Motion “Busy” Output
• Clock Pulses and Step Direction Outputs
• CW and CCW Index Inputs
• CW and CCW Jog/Run and Fast Job Inputs
• Two “Go to Home Position” Modes
• TTL-MOS Compatible
• Index...
                                            
                                                    1
PCL451
Manual Preset Indexer
User’s Guide
#L010074            July 2002
910 East Orangefair Lane, Anaheim, CA 92801
e-mail: [email protected](714) 992-6990  fax: (714) 992-0471
website: www.anaheimautomation.com
ANAHEIM AUTOMATION   
                                            
                                                    May 2002
PCL501 Programmable Controller
PRODUCT RELEASE
Easy to Use Windows Software: Dimensions:
The PCL501 is an economical single axis step motor controller containing 2 Kbytes of non-volatile stored
programming space. It provides flexible, independent control of step motors with clock and direction outputs from
computers or machine controllers with a serial port. It is also capable of stand-alone operation making it an
embedded machine controller. The easy to use Windows software, SMC50WIN, can be...
                                            
                                                    FEATURES
DESCRIPTION
910 East Orangefair Ln.  Anaheim, CA 92801     Tel. (714) 992-6990     Fax. (714) 992-0471     www.anaheimautomation.com
DIMENSIONS
The PCL501 programmable controller is an economical single axis step motor controller containing 2Kbytes 
of non-volatile stored programming memory.  It provides fl exible, independent control of step motors with 
clock and direction outputs from computers or machine controllers with a serial port.  It is also capable of 
stand-alone operation making it...
                                            
                                                    FEATURES
SPECIFICATIONS
910 East Orangefair Ln.  Anaheim, CA 92801     Tel. (714) 992-6990     Fax. (714) 992-0471     www.anaheimautomation.com
DIMENSIONS
PCL601 Programmable Control-
ler provides you with a complete 
motion solution in a compact 
package.  It simplifi es program-
ming tasks and provides the 
essential features for any posi-
tioning system.  Say goodbye to 
PLC’s and time consuming Lad-
der Logic Programs for good.
The PCL601 features the ability 
to connect to a PC and instantly...
                                            
                                                    L010207  December 2005  Multiple Axes Setup for PCL601 
1. Power up the 1st unit ONLY and connect the RS485 or USB connection to the 1st unit. 
2. Under Setup >Axis menu click “Define Axis” and enter 0. 
3. Under Setup >Axis menu click “Select Axis” and enter 0. 
4. Under Setup menu click “Connect”. 
5. Text appears on top right of SMC60WIN “The Unit is Connected” and the version of the firmware is 
displayed as well. This text should turn blue when connected. 
6. Under Setup menu click “Disconnect”. 
7....