    							Security made Simplecomes in the form of Logic Six, one of the worlds easiest to install
    and operate systems. One of the biggest areas of concern within the Security industry is the
    complexity often associated with system programming and operation. Logic Six still provides
    many of the functions of the G3 family of control panels, appealing to both installers and
    end users. Having been specifically designed to simplify and speed up installation and
    programming, Logic Six benefits end users by reducing false alarmsgenerated through
    incorrect operation.
    6-zone proximity based control panel 
    Keyfob controlled with each Zone independently identified on the control panel providing ample security, Personal Attack (PA) and
    24hr tamper detection for most domestic properties.
    Easy to operate 
    There is no keypad or user code, programming and operation are so simple they can be carried out by offering a keyfob to the panel.
    Easy to install and program 
    Simple three part housing facilitates ease of installation with only two switch settings within the control panel to simplify
    programming meaning less time on site.
    Sold with two preprogrammed keyfobs 
    Allowing for higher security integrity and reduced programming time.
    Up to 8 individually coded keyfobs can be programmed 
    In total 8 keyfobs can be programmed to work with one control panel affording system control for up to 8 individual users.
    Part set, selectable entry time, 
    Part set and entry time are easily selectable via the relevant switches within the control panel.
    Logic SixIntruder Panel 
    						
    							Logic SixFeatures
    STYLED ROBUST
    POLYCARBONATE
    ENCLOSURE
    DISCRETE KEYFOBS EASILY ATTACHED
    TO EXISTING KEY RING
    KEYPAD NOT REQUIRED -
    PROGRAMMED KEYFOB OFFERED TO
    DEPRESSION TO OPERATE SYSTEM
    PART SET AND ENTRY
    TIME SWITCHES ON BOARD SOUNDER TO ASSIST
    FOR LOCAL ALERTS 
    6 PRESET ZONES,
    PA AND TAMPER
    WALK/ALARM
    TEST BUTTONMULTIPLE CABLE
    ENTRY POINTS UP TO 2.1AH
    BATTERY
    COMPARTMENT
    BELL / STROBE OUTPUTS 
    						
    							Logic SixThe simple to Install Panel
    FEATURES
    3 switches to programme / test
    Easy to install
    Operation via proximity technology (no
    keypad required) integrated into the control
    panel
    No PIN to remember
    Simple to operate
    Reduced false alarms
    Unique lower cost solution
    More attractive to users uncomfortable
    with traditional alarm technology
    Proven, “Simple Set” Technology
    Quality, reliability you expect from ADE
    Will support speech dialler extension
    Tamper protection
    Installation in three easy steps
    Setting the System Part Setting the System Unsetting the System
    STEP THREE:Operation
    Full or Part Set Set Entry Time Walk / Alarm Test
    STEP TWO:Programming and Testing
    Mounting pulling cable through and wiring the Panel
    STEP ONE:Mounting the panel 
    						
    							Logic SixSpecification
    LOGIC SIX / KEYFOB
    Indicators on Control panel Zone 1-6 (red), Tamper –TA (amber), Personal Attack-PA,  
    Power, Learn (amber), Error (red) and Day (green)
    6 Zones +ve loop, security zones
    Tamper –ve loop global, always active
    PA+ve loop, always active
    Simple Set Interface No
    RKP Indication No
    User keyfobs 2 supplied with the panel and up to a maximum of 8 can be  
    learnt to operate the panel
    Keyfob operating range 20mm nominal from centre depression
    Proximity reader  125KHz inductive
    Bell Output 12V latching, timed 20 minutes
    Strobe Output 12V latching
    Extension Speaker 16 Ohm 260mA
    Entry time Programmable by DIP switch 15 seconds or 30 seconds
    Exit time 30 seconds
    Full/Part Set Programmable by DIP switch
    Walk and Alarm Tests Selectable by push button switch
    Zone Input Delay 640mS
    Set +ve Output 0V in Day (Sinking 40mA) 12V in Set (Sourcing 10mA)
    Control panel current consumption  Standby 80mA  Alarm 250mA 
    Low voltage Output 13.8V dc stabilised (+/-5%) up to 350mA
    Communicator outputs Bell output can be used to trigger speech dialler
    Rechargeable Battery 12V, 1.2 or 2.1Ah
    Charge Voltage 13.8V dc (+/-5%)
    Board Fuses 1x1.6A & 2x1A 20mm quick blow
    Mains Input fuse 125mA, 250V type T (anti-surge)
    Total current output 1 Amp when supported by fully charged battery
    Mains supply voltage 230V (+/-10%) 50Hz max load 0.2A
    Ambient Operating temperature 0°C to 40°C
    Enclosure construction 3mm Polycarbonate
    Panel dimensions  H 200mm  W 253mm D 55mm
    Keyfob dimension  L 58.5mm W 18.5mm
    ADE
    The Arnold Centre  Paycocke Road  Basildon  Essex  SS14 3EA  United KingdomTechnical Helpline Te l01268 563720
    Customer Service Te l01268 563000Literature Helpline Te l0870 240 [email protected]
    Customer Service Fax01268 563563Literature Helpline Fax0870 240 3386Websitewww.ade.co.uk
    Registered Office:Novar House  24 Queens Road  Weybridge  Surrey  KT13 9UXRegistered No. 189291Literature Ref:Logic Six/03-02-01/012
    ADE offers comprehensive project support, design and technical advice. Please contact our helpline on the number below.
    LIST NUMBER DESCRIPTION
    LGSIX/01 LOGIC SIX COMPACT 
    WITH TWO 
    LEARNT KEYFOBS
    SS/F KEYFOB 
    Novar Intelligent Building Systemsoffers a uniquely comprehensive range of solutions for specifiers and installers of fire, security, building management, datacoms and
    electrical installation products and is equipped to provide a single source solution for all your requirements. 
    						