    Press the Menu button to open the OSD menu. Press ◄► to move to the Settings 2 menu. 
    Press ▲▼ to move to the Advanced 2 menu and then press Enter or ►. Press ▲▼ to move up 
    and down in the Advanced 2 menu. Press ◄► to enter and change values for setting. 
     
    ITEM DESCRIPTION 
    Sleep Timer (min) Press the cursor ◄► buttons to enter and set Sleep timer. The projector automatically 
    turns off after the preset period of time. 
    Source Filter Press  (Enter) / ► to enter the Source Filter menu. See page 44 for more 
    information on Source Filter.   
    						
    							— 44— 
    Source Filter 
    Press the ENTER button to enter the Source Filter sub menu. 
     
    ITEM DESCRIPTION 
    HDMI1/MHL Press the ◄► buttons to enter and enable or disable the HDMI1/ MHLJcompatible 
    sourceK 
    eDMI2 Press the ◄► buttons to enter and enable or disable the HDMIO sourceK 
    VGA1 Press the ◄► buttons to enter and enable or disable the VGA1 source. 
    VGA2  Press the ◄► buttons to enter and enable or disable the VGA2 source. 
    pJVideo Press the ◄► buttons to enter and enable or disable the SJVideo sourceK 
    Composite Video Press the ◄► buttons to enter and enable or disable the Composite Video source. 
      
    						
    							— 45— 
    MAINTENANCE AND SECURITY 
    Replacing the Projection Lamp 
    The projection lamp should be replaced when it burns out. It should only be replaced with a 
    certified replacement part, which you can order from your local dealer.  
     Important: 
    a. The projection lamp used in this product contains a small amount of mercury. 
    b. Do not dispose this product with general household waste. 
    c. Disposal of this product must be carried out in accordance with the regulations of your local  
    authority. 
     Warning: 
    Be sure to turn off and unplug the projector at least 30 minutes before replacing the lamp. 
    Failure to do so could result in a severe burn. 
     
     Caution: 
    In rare cases the lamp bulb may burn out during normal operation and cause glass dust or 
    shards to be discharged outward from the rear exhaust vent. 
    Do not inhale or do not touch glass dust or shards. Doing so could result in injury.  
    Always keep your face away from the exhaust vent so that you do not suffer from the gas and 
    broken shards of the lamp. 
    When removing the lamp from a ceiling-mounted projector, make sure that no one is under the 
    projector. Glass fragments could fall if the lamp has been burned out.  
     IF A LAMP EXPLODES 
    If a lamp explodes, the gas and broken shards may scatter inside the projector and they may 
    come out of the exhaust vent. The gas contains toxic mercury. 
    Open windows and doors for ventilation. 
    If you inhale the gas or the shards of the broken lamp enter your eyes or mouth, consult the 
    doctor immediately.   
    1.  Remove the single screw 
    on the lamp compartment 
    cover. 
           
    						
    							— 46— 
    2.  Remove the lamp 
    compartment cover. 
     
    3.  Remove the two screws 
    from the lamp module. 
     
    4.  Lift the module handle up. 
    5.  Pull firmly on the module  
    handle to remove the lamp 
    module. 
    6.  Reverse steps 1 to 5 to 
    install the new lamp 
    module.  
    While installing, align the 
    lamp module with the  
    connector and ensure it is 
    level to avoid damage. 
    Note: The lamp module 
    must sit securely in place 
    and the lamp connector 
    must be connected 
    properly before tightening 
    the screws. 
     
         
    						
    							— 47— 
    Resetting the Lamp 
    After replacing the lamp, you should reset the lamp hour counter to zero. Refer to the following: 
    1.  Press the MENU button to open 
    the OSD menu. 
     
    2.  Press the cursor ◄► button to 
    move to the Settings 2 menu. 
    Press the cursor button to move 
    down to Advanced 1 and press 
    enter. 
    3.  Press the cursor ▼▲ button to 
    move down to Lamp Hour Reset. 
     
    4.  Press the cursor ► or Enter 
    button.  
    A message screen appears. 
     
    5.  Press ▼▲◄► buttons to reset 
    the lamp hour. 
    6.  Press the MENU button to get 
    back to Settings 2. 
      
    						
    							— 48— 
    Cleaning the filter (filter: optional parts) 
    The air filter prevents dust from accumulating on the surface of the optical elements inside the 
    projector. If the filter is dirty or clogged, your projector may overheat or degrading the projected 
    image quality. 
    1.  Turn off the projector, and 
    unplug the AC power cord 
    from the AC outlet. 
     
    2.  Cleaning the filter with a 
    vacuum cleaner. 
     
     Caution: 
    Recommend avoiding dusty or smoky environments when you operate the projector, it may 
    cause poor image quality. 
    If the filter is heavily clogged and unable to clean, replace a new filter. 
     
    Note:  
    Using a ladder is recommended to access the filter. Do not remove the projector from the 
    wall mount.     
    						
    							— 49— 
    Replacing the Filter 
    1.  Turn off the projector, and 
    unplug the AC power cord 
    from the AC outlet.  
    Clean up the dust on the 
    projector and around the 
    air vents.  
    Pull out the filter cover and 
    remove from the projector 
    Use soft brush gently to 
    clean the filter dust both 
    side.  
    2.  Or lift the filter from the 
    filter cover. 
     
    3.  
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  
    Replace a new filter 
    module or replace filter into 
    cover. 
     
    4.  Replace the filter cover 
    back to the projector by 
    pushing gently in the  
    direction shown. 
     
     Waming: 
    Do not wash the filter with the water or other liquid matter.
      
     Important: 
    When the lamp is replaced, the filter should also be replaced, not cleaned.        
    						
    							— 50— 
    Cleaning the Projector 
    Cleaning the projector to remove dust and grime will help ensure trouble-free operation.  
    Cleaning the Projector Mirror: 
     
     
    Remove dust with a “Bellows/Lens Blower”  
    readily available from Camera shops to prevent scratching the mirror when subsequently wiped. 
     Cautions: 
    1. Always turn the projector off and allow to cool for at least 30 minutes prior to cleaning. 
    2. Never touch the projector mirror or Lens directly by hand. 
    3. Do not use abrasive cleaners, solvents or other harsh chemical cleaners. 
        
    						
    							— 51— 
    Cleaning the Case 
    Refer to the following to clean the projector case. 
    1. Wipe off dust with a clean dampened cloth. 
    2. Moisten the cloth with warm water and mild detergent (such as used to wash dishes), and 
    then wipe the case. 
    3. Rinse all detergent from the cloth and wipe the projector again. 
     Caution: 
    To prevent discoloration or fading of the case, do not use abrasive alcohol-based cleaners. 
     
     Warning: 
    1. Be sure to turn off and unplug the projector at least 30 minutes before cleaning. Failure to do 
    so could result in a severe burn. 
    2. Use only a dampened cloth when cleaning. Do not allow water to enter the ventilation 
    openings on the projector.  
    3. If a little water gets into the projector interior while cleaning, leave unplugged in a well-
    ventilated room for several hours before using. 
    4. If a lot of water gets into the projector interior when cleaning, have the projector serviced. 
     
     
     
     
     
     
     
     
     
        
    						
    							— 52— 
    Using the Physical Lock 
    Using the Kensington® Lock 
    If you are concerned about security, attach the projector to a permanent object with the 
    Kensington slot and a security cable.  
     
    Note: 
    Contact your vendor for details on purchasing a suitable Kensington security cable.  
    The security lock corresponds to Kensington’s MicroSaver Security System. If you have any 
    comment, contact: Kensington, 2853 Campus Drive, San Mateo, CA 94403, U.S.A. Tel: 800-
    535-4242, http://www.Kensington.com. 
     
    Using the Security Bar 
    In addition to the password protection function and the Kensington lock, the Security Bar helps 
    protect the projector from unauthorized removal. 
    See the following picture. 
     
     
        
    						
    All Vivitek manuals Comments (0)

    Related Manuals for Vivitek Dh758ust User Manual