Page 61

 
- 58 - Item Description  Specification 
Character code   PC-850: PC-850 
PC-852: PC-852 
PC-857: PC-857 
PC-8: PC-8 
PC-851: PC-851 
PC-855: PC-855 
PC-866: PC-866 
PC-1250: PC-1250 
PC-1251: PC-1251 
PC-1252: PC-1252 
PC-1253: PC-1253 
PC-1254: PC-1254 
PC-1257: PC-1257 
LATIN9: LATIN9 
Arabic: Arabic 
UTF-8: UTF-8 FONT 
 
Font “0”   0 :  Without slash 
0 :  With slash 
SPEED RS232C communication speed    2400:  2400 bps 
 4800:  4800 bps 
 9600:  9600 bps 
 19200:  19200 bps 
 38400:  38400 bps...

Page 62

 
- 59 - Item Description  Specification 
MESSAGE Language for LCD messages 
ENGLISH: English 
GERMAN: German 
FRENCH: French 
DUTCH: Dutch 
SPANISH: Spanish 
JAPANESE: Japanese 
ITALIAN: Italian 
FORWARD WAIT Forward feed standby after an 
issue ON: Enabled 
(A fine adjustment value for 
the stop position is also 
printed.) 
OFF: Disabled 
CODE Control code   
AUTO: Automatic selection
ESC LF NUL:  ESC LF NUL 
method 
{ | }:  { | } method 
××{{  Any code set 
(Described in hex. 
code) 
IBM HOST:    |...

Page 63

 
- 60 - Item Description  Specification 
RIBBON NEAR END Ribbon near end detection   
30 m: A ribbon near end state is 
detected when the remaining 
ribbon length is 
approximately 30 m. 
70 m: A ribbon near end state is 
detected when the remaining 
ribbon length is 
approximately 70 m. 
OFF:  A ribbon near end state is not 
detected. 
EX.I/O MODE Expansion I/O operation mode  TYPE1:  Standard mode 
TYPE2: In-line mode 
PLUG & PLAY Plug-and-play operation    ON:  A plug-and-play operation is...

Page 64

 
- 61 - Item Description  Specification 
SOCKET PORT Socket communication port 
number ON: Socket communication 
function is enabled. 
OFF: Socket communication 
function is disabled. 
Port number: 0 to 65535 
BASIC BASIC interpreter    ON:  BASIC interpreter function is 
enabled. 
OFF:  BASIC interpreter function is 
disabled. 
BASIC TRACE BASIC interpreter trace    ON:  Trace function is enabled. 
OFF:  Trace function is disabled. 
DHCP DHCP    ON:  DHCP function is enabled. 
OFF:  DHCP function is...

Page 65

 
- 62 - Item Description  Specification 
SYSTEM 
PASSWORD System mode password operation OFF:  Password  is  not  asked  to 
enter the system mode. 
ON:  Password is asked to enter 
the system mode. 
PEEL OFF TRQ Strip motor torque  R0: Low 
R1:  ↑ 
R2:  ↓ 
R3: High 
RTC BATT.CHK RTC low battery check  ON:  Enabled 
OFF: Disabled 
RTC RENEWAL RTC data renewal timing  BATCH:  Per batch 
PAGE: Per page 
TONE TABLE Print head applied current table 
setting TYPE1:  Standard table 
TYPE2:   Additional table...

Page 66

 
- 63 - (3) Memory check  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
EEPROM  OK 
OK:  Data in the check area can be properly read/written. 
NG:  Data in the check area cannot be properly read/rewritten. 
Backup memory (EEPROM) 
PROGRAM  B-SA4T     
    MAIN  15OCT2002  V1.0A:1A00  Model name   
Creation date   
(Day-Month-Year)Version
Name PROGRAM:  Program area 
Checksum 
    BOOT  20SEP2002  V1.0  :8500 
Creation date   
(Day-Month-Year)Version
Name  BOOT:  Boot area 
Checksum 
KANJI...

Page 67

 
- 64 - (4) Sensor check  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 SENSOR1 00000000,00000000
Thermal head open sensor 
  1:  The head is closed. 
  (If the head is opened, printing is not performed.) 
Blank (Fixed to 0) 
Blank (Fixed to 0) Cutter home position sensor 
 0: Home position 
  1:  Outside the home position 
Blank (Fixed to 0) 
 
Ribbon take-up motor sensor 
  0:  Outside the slit 
  1:  Inside the slit 
Ribbon feed motor sensor 
  0:  Outside the slit 
  1:...

Page 68

 
- 65 -  
 
 
 
Resistance 203 dpi  300 dpi 
rank  Average resistance (ohm) 
0  748 to 758  1100 to 1116 
1  759 to 770  1117 to 1133 
 
(5)  Expansion I/O check   
 
 
 
 
  *  Connect the cable as illustrated below, then check the following cases: high output/high 
input, low output/low input. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(6)  Internal serial I/F check   
 
 
 
 
OK: Normal data 
NG:  Abnormal data, or the loop-back jig is not connected. 
Expansion I/O  EXP.I/O NG 
R 
R
R
R
R
R
R
Vcc
LED
R = 300 ohms...

Page 69

 
- 66 - (7)  SIO I/F check   
 
 
 
 
 
(8)  Strip sensor check   
 
 
 
 
(9)  RFID module check   
 
 
 
 
 
 
 
Module revisions and corresponding countries 
B-SA704-RFID-U2-KR-R (Supported from C2.0C) 
Revision Country 
R03  US, AU, KR, TW, BR 
Note: From the R03 module, KR supports the revised radio law. 
 
B-SA704-RFID-U2-EU-R 
Revision Country 
R11 EU, IN 
Note: IN is supported from C2.0C. 
 SIO
 NG  N G 
DIN  OK: Normal data 
  NG: Abnormal data, or the loop-back jig is not connected. 
DSUB  OK:...

Page 70

 
- 67 -
6.3  VARIOUS PARAMETERS SETTING 
6.3.1  Various Parameters Setting Operation Example 
 
     Power OFF 
  (1)  Power off state 
             
        [FEED] [RESTART] (2)  While holding the [FEED] and [RESTART] keys 
down, turn the power on. 
 
< 1 > D I A G .       V 1 . 2 A
 
             
 (3)  The self-test menu is displayed. 
              
        [FEED] 
 
(4)  Press the [FEED] key. 
< 2 > P A R A M E T E R    S E T
 
             
 (5)  System mode menu display 
 (Parameter setting)...
Start reading Toshiba B Sa4t G Manual

Related Manuals for Toshiba B Sa4t G Manual

All Toshiba manuals