Installation Contents of Shipping Boxes The Tone Commander 1030/1560 system is shipped in two boxes: one for the console, and one for the central processing unit (CPU). Please compare the contents of these boxes with the lists below. Contact your distributor if any items are missing or damaged. Console Box: (1) console (2) 7´ line cords (1) handset with cord (1) handset cradle (2) cradle mounting screws (1) Attendant’s Guide (1) Quick Reference Card (1) bag of clear keycaps (1030: 41, 1560: 46) (2)...
Page 12
CPU Installation Mounting CPU and Blocks Refer to Figure 5 on page 16. 1. Fasten a plywood sheet to the wall with hardware suitable for the wall material. 2. Using the supplied mounting template, mark and pre-drill the mounting holes for the CPU. Make sure that the CPU mounting location is within 5 feet of a standard grounded power outlet. Allow at least one foot of free space above and below the CPU for ventilation. 3. Drive in four suitable fasteners (such as #10×¾ pan head tapping screws), leaving the...
Page 13
Cabling to Blocks Refer to Figure 5 on page 16. 1. Punch down the cables to the blocks as shown in the Wire Color columns of Tables 1, 2, and 3. The cable with the male connector should be punched down to the right side of block #1. 2. Plug the 25 pair cable from block #1 into the connector on the left side of the main CPU circuit board. 3. Plug the cable from the left side of block #2 into the connector on the lower right side of the main CPU circuit board. 4. Plug the cable from the right side of block...
Page 14
CPU Chassis Grounding This ground connection is required for safety and EMI shielding. It is usually provided by the 3rd wire on the CPU power cord. If the integrity of the power outlet ground is questionable, use the ground connection shown below for the 1030/1560 CPU. 1. Connect a solid copper #10 or #12 AWG wire to the ground terminal on the CPU. The wire should be tightly clamped between the ground screw and the cup washer. 2. Connect the wire to an approved ground, such as MGN (multi-grounded...
Page 15
Line Testing Connect a test telephone to each line; verify the presence of dial tone, and break dial tone by dialing a number. The 1030 and 1560 allow DTMF tone dialing only – refer to the Telco/PABX Requirements section. Test any additional features ordered with the lines. Open circuit voltage must be approximately 48 volts. Station Connections Station Monitoring 13-102360 Rev. HPage 15 Tone Commander 1030/1560 Installation Instructions Figure 4 ConnectT(Tip) andR(Ring) from each monitored station to...
Page 16
Page 1613-102360 Rev. H Tone Commander 1030/1560 Installation Instructions Figure 5– 1030/1560 Typical Installation
Page 17
CONNECTOR #1 PIN NO. WIRE COLOR(left side of block unused)DESIGNATION(right) 26·······WHT-BLU······· – ··········1TN 1·······BLU-WHT······· – ··········1RN 27·······WHT-ORN······· – ··········1C1 2·······ORN-WHT······· – ··········1C2 28·······WHT-GRN······· – ··········1C3 3·······GRN-WHT······· – ··········1C4 29·······WHT-BRN······· – ··········2TN 4·······BRN-WHT······· – ··········2RN 30·······WHT-SLT ······· – ··········2C1 5·······SLT-WHT ······· – ··········2C2 31·······RED-BLU······· –...
Page 18
CONNECTOR #2 CONNECTOR #3 PIN NO. WIRE COLORDESIGNATION(left)DESIGNATION(right) 26·······WHT-BLU·······T1···········T16 1·······BLU-WHT·······R1···········R16 27·······WHT-ORN·······T2···········T17 2·······ORN-WHT·······R2···········R17 28·······WHT-GRN·······T3···········T18 3·······GRN-WHT·······R3···········R18 29·······WHT-BRN·······T4···········T19 4·······BRN-WHT·······R4···········R19 30·······WHT-SLT ·······T5···········T20 5·······SLT-WHT ·······R5···········R20...
Page 19
CONNECTOR # 4CONNECTOR #5 PIN NO.WIRE COLORDESIGNATION(left)DESIGNATION(right) 26·······WHT-BLU·······T31 ··········T46 1·······BLU-WHT·······R31 ··········R46 27·······WHT-ORN·······T32 ··········T47 2·······ORN-WHT·······R32 ··········R47 28·······WHT-GRN·······T33 ··········T48 3·······GRN-WHT·······R33 ··········R48 29·······WHT-BRN·······T34 ··········T49 4·······BRN-WHT·······R34 ··········R49 30·······WHT-SLT ·······T35 ··········T50 5·······SLT-WHT ·······R35 ··········R50...
Page 20
Console Cable Installation Wall Jack PinoutWall Jack Typical Wire ColorConsole #1 Designation (connector 1)Console #2 Designation (connector 1)Typical 3 Pair Console Cable Wire Color(actual wire color) 1 WHT 1C3 (WHT-GRN) 2C3 (RED-BLU) WHT-GRN 2 BLK 1C1 (WHT-ORN) 2C1 (WHT-SLT) WHT-ORN 3 RED 1RN (BLU-WHT) 2RN (BRN-WHT) BLU-WHT 4 GRN 1TN (WHT-BLU) 2TN (WHT-BRN) WHT-BLU 5 YEL 1C2 (ORN-WHT) 2C2 (SLT-WHT) ORN-WHT 6 BLU 1C4 (GRN-WHT) 2C4 (BLU-RED) GRN-WHT Table 4 –Console “Voice/Data” Jack Pinout Page...