Home > Sony > CD Player > Sony Scd-1 Service Manual

Sony Scd-1 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sony Scd-1 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 980 Sony manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    5-2. ADJUSTMENT-1 MODE
    This mode is a special mode used to perform overall adjustment,
    optical pick-up height adjustment, and service check.
    Note:
    1. Wrong setting method can cause a trouble.
    2. Never operate the set with the loading panel mounted, which otherwise
    causes a trouble.
    Setting Method:
    1. With the power turned off, press the  
    !  button while pressing
    the [DIGITAL OUT] button and 
    l button.
    2. Display of ÒbbbÓ implies that the set is now in the Adjust-
    ment-1 Mode.
    Resetting Method:
    Press the  
    !  button to turn the power off, and disconnect the plug
    from the socket.
    5-3. ADJUSTMENT-2 MODE
    This mode is a special mode used to perform CLV jitter check and
    usually movement check.
    Note:
    1. Wrong setting method can cause a trouble.
    2. Never operate the set with the loading panel mounted, which otherwise
    causes a trouble.
    Setting Method:
    1. With the power turned off, press the  
    !  button while pressing
    the [TIME] button and 
    H button.
    2. Display of Ò# OPEN #Ó implies that the set is now in the Ad-
    justment-2 Mode.
    Resetting Method:
    Press the  
    !  button to turn the power off, and disconnect the plug
    from the socket.
    Adjustment item
    *1: Disc check listDisplay Result of Disc Check
    Discchk DO SL No disc
    Discchk D1 SL SL
    Discchk D2 CD CD
    Discchk D3 CD Hybrid CD layer
    Discchk D3 HD Hybrid HD layer
    Discchk D4 D0 DL L0 layer
    Discchk D4 D1 DL L1 layer
    Codes Contents Remarks Disc
    01 LD ON/OFF CD, SL, DL
    02 Spindle ON/OFF CD, SL, DL
    03 Forcus Search CD, SL, DL
    04 Forcus Servo ON/OFF CD, SL, DL
    05 Track Servo ON/OFF CD, SL, DL
    06 CLV ON CD, SL, DL
    07 Sled Servo ON/OFF CD, SL, DL
    22 Tilt Servo ON/OFF CD, SL, DL
    23 Tilt Bias Up CD, SL, DL
    24 Tilt Bias Down CD, SL, DL
    30 Disc Check CD, SL, DL
    5: Thresholds
    check              
    Go
    60 Overall Adjustment 9: No thresholds CD, SL, DL
    check
    0: Cancel
    61 Result Display1: Proceed
    2: ReturnCD, SL, DL
    62 Adj. Value  Clear9: Go
    0: CancelCD, SL, DL
    PLAY PLAY CD, SL, DL
    PAUSE PAUSE CD, SL, DL
    STOP STOP CD, SL, DL
    NEXT NEXT CD, SL, DL
    PREV PREV CD, SL, DL
    SACD select
    FILTER Focus Search/PLAY(SACD/CD key)SL
    CD select
    (SACD/CD key)CD
    Note:
    1. Selection of an adjustment item where no disc is present could damage
    the optical pick-up.
    2. Do not use other than above listed codes.
    *1
    Adjustment-1 Mode ListNote: Set the CD1/CD2 switch on the remote commander to CD1.
    Traverse check, S curve check,
    Adjustment-1RF level check, optical pick-up
    Modeheight adjustment, and see contents of
    Adjustment-1 Mode list.
    Adjustment-2CLV jitter check and usually
    Modemovemant check 
    						
    							12
    6. Press the H button.
    7. Press the - button and 7 button, and the - button and 5
    button on the remote commander successively to turn off the
    tracking servo.
    8. Check that the waveform on oscilloscope is within the level
    A and B specifications.
    9. After checking, press the 
    x button.
    10. Repeat steps 3 through 9 respective discs.
    11. Press the 
    ! button to turn the power off.
    Specified Value:
    DiscA
    B
    SATD-S2
    SATD-S3 1.3 to 2.4 Vp-p - 0.1 to +0.1 V
    TCD-784
    bbb              CD1
                 Discchk XX XX
    Disc type (refer to Disc check list (page 11))
    Procedure:
    1. Connect an oscilloscope to the TP516(TE) and TP501(VC) on
    the MAIN board.
    2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
    SECTION 5 (page 11))
    3. Set a disc (SATD-S2, SATD-S3, or TCD-784).
    4. Press the 3 button and - button on the remote commander
    to make the disc type checked.
    Note:If the disc check was made in the Adjustment-1 Mode, pressing
    another button immediately after pressing the 3 and - buttons
    on the remote commander could cause the microcomputer to run
    out of control, thus requiring extreme care.
    5. Confirm that the disc was checked.
    SECTION  6
    ELECTRICAL  ADJUSTMENTS
    Note on Adjustment
    1. When the following parts were replaced, adjust and check the
    items marked with a in the given order.
    Optical IC on RF or Spindle
    Adjustment & check pick-up MAIN board motor (M7)
    1. Optical Pick-up
        Height Adjustmenta´a
    2. Overall Adjustmentaa´
    3. Traverse Checka´´
    4. S Curve Checka´´
    5. RF Level Checka´´
    6. CLV Jitter Check´´a
    2. Adjustment jigs
    The following jigs are exclusively used for electrical adjust-
    ment and check of this set. Do not use them for other applica-
    tions.
    (1) Disc
    Model Type*1 Category Applications
    SATD-S1 SL 8cm disc Optical pic-kup H adj.
    SATD-S2 SL Reference disc Overall adj. and check
    SATD-S3 DL Reference disc Overall adj. and check
    SATD-S4 SL Reference disc Audio characteristic check
    TCD-784 CD Reference disc Overall adj. and check
    *1 SL: Single Layer
    DL: Dual Layer
    (2) Remote commander: Assessory for set or RM-D950 (Part No.
    1-473-944-1)
    (3) Extension cable (Part No. J-2501-164-A) 2 pcs.
    3. In making adjustment and check, set the CD1/CD2 switch on
    the remote commander to CD1.
    4. The impedance of oscilloscope should be more than 10M .Traverse Check
    Connection:
    MAIN board
    TP516 (TE)
    TP501 (VC)+
    – oscilloscope
    (auto or normal mode)
    A
    B
    VCCenter fo the waveform Traverse waveform
    Par ts
    Adjustment Location : See page16. 
    						
    							13
    6. Press the H button.
    7. Check that the waveform on oscilloscope is clear, and the level
    and jitter of waveform satisfy the specifications.
    8. After checking, press the 
    x button.
    9. Repeat steps 3 through 8 for respective discs.
    10. Press the 
    ! button to turn the power off.
    Specified Value:
    DiscAJitter (displayed value)
    SATD-S2 1.25 to 1.65 Vp-p 20 (Hex) or less
    TCD-784 1.3 to 1.7 Vp-p 15 (Hex) or less
    bbb              CD1
                 Discchk XX XX
    Disc type (refer to Disc check list (page 11))
    6. Press the - button and 1 button, the - button and 2 but-
    ton, and the - button and 3 button on the remote commander
    successively to execute the focus search.
    7. Check that the waveform on oscilloscope is within the level
    A and B specifications.
    8. After checking, press the  
    x  button.
    9. Repeat steps 3 through 8 for respective discs.
    10. Press the ! button to turn the power off.
    Specified Value:
    Disc
    AB
    SATD-S2
    1.5 to 2.3Vp-p - 0.1 to +0.1V
    TCD-784
    S Curve Check
    Connection:RF Level Check
    Connection:
    MAIN board
    TP524 (FE)
    TP501 (VC)+
    – oscilloscope
    (normal mode
    )
    Procedure:
    1. Connect an oscilloscope to the TP524(FE) and TP501(VC) on
    the MAIN board.
    2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
    SECTION 5 (page 11))
    3. Set a disc (SATD-S2 or TCD-784).
    4. Press the 3 button and - button on the remote commander
    to make the disc type checked.
    Note:If the disc check was made in the Adjustment-1 Mode, pressing
    another button immediately after pressing the 3 and - buttons
    on the remote commander could cause the microcomputer to run
    out of control, thus requiring extreme care.
    5. Confirm that the disc was checked.
    A
    B
    S curve waveform
    VC
    MAIN board
    TP503 (RF)
    TP501 (VC)+
    – oscilloscope
    (auto mode)
    Procedure:
    1. Connect an oscilloscope to the TP503(RF) and TP501(VC) on
    the MAIN board.
    2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
    SECTION 5 (page 11))
    3. Set a disc (SATD-S2 or TCD-784).
    4. Press the 3 button and - button on the remote commander
    to make the disc type checked.
    Note:If the disc check was made in the Adjustment-1 Mode, pressing
    another button immediately after pressing the 3 and - buttons
    on the remote commander could cause the microcomputer to run
    out of control, thus requiring extreme care.
    5. Confirm that the disc was checked.
    VOLT/DIV: 200 mV
    TIME/DIV: 500 ns RF signal waveform
    A
    bbb              CD1+ 00 00 ~00 09
    Jitter value
    (HEX)
    not fixed
    Adjustment Location : See page16.
    Adjustment Location : See page16.
    bbb              CD1
                 Discchk XX XX
    Disc type (refer to Disc check list (page 11))
    Note: For easier observation of this waveform, extend the sweep time
    and raise the brightness.Note: Clear RF waveform refers to the waveform where à shapes should
    be distinctively observed in the center.
    Display example: 
    						
    							14
    Optical Pick-up Height Adjustment
    Connection:
    MAIN board
    TP702 (MNT4)
    TP703 (MNT5)
    TP521 (GND)+
    +
    – oscilloscope
    (normal mode
    )
    (CH1) (CH2)
    CLV Jitter Check
    Connection:
    A
    CLV jitter waveform
    MAIN board
    TP515 (PI)
    TP511 (FOUT)
    TP501 (VC)+
    +
    – storage
    oscilloscope
    (normal mode)
    (CH2) (CH1)
    Procedure:
    1. Connect an oscilloscope to the TP515(PI)(CH1),
    TP511(FOUT) (CH2) and TP501(VC) on the MAIN board.
    2. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
    SECTION 5 (page 11))
    3. Set a disc (SATD-S1).
    4. Press the [FILTER] button to set the Focus Search mode.
    5. Loosen the OP height adjusting screw 1, and while shifting
    the Holder (R2), adjust the height so that the waveform on
    oscilloscope satisfies the specified value.
    6. Press the [FILTER] button to set the Play mode.
    7. Adjust the TAN skew 2 so as to attain most preferable jitter
    value on the display.
    8. Press the [FILTER] button to set the Focus Search mode.
    9. Check that the B value of waveform on oscilloscope satisfies
    the specification.
    10. Repeat steps 5 through 9.
    11. Lock the OP height adjusting screw 1 when adjustment fin-
    ished.
    12. Press the 
    x button.
    13. Press the 
    ! button to turn the power off.
    Specified Value: B is more than 0, and less than A/3
    AB
    VC
    VCPI
    FOUT
    Procedure:
    1. Connect an oscilloscope to the TP702(MNT4)(CH1),
    TP703(MNT5)(CH2) and TP521(GND) on the MAIN board.
    2. Set the Adjustment-2 Mode. (See 5-3. Adjustment-2 Mode in
    SECTION 5 (page 11))
    3. Set a disc (SATD-S2 or TCD-784).
    4. Press the 
    H button.
    5. Move the sled to the middle track.
    ¥ Sled middle track
    SATD-S2:TN05
    TCD-784:TN05
    6. Check that the A value of waveform on oscilloscope satisfies
    the specification.
    7. After checking, press the 
    x button.
    8. Repeat steps 3 through 7 for respective discs.
    9. Press the 
    ! button to turn the power off.
    Specified Value:
    DiscA
    SATD-S2
    55 µsec or less
    TCD-784
    *1
    *1: Normal-trigger the oscilloscope using FOUT on CH2.
    2TAN skew
    1OP height
    adjusting screw
    Holder (R2)
    Adjustment Location : See page16.
    Adjustment Location : See page16. 
    						
    							15
    Overall Adjustment
    Procedure:
    1. Set the Adjustment-1 Mode. (See 5-2. Adjustment-1 Mode in
    SECTION 5 (page 11))
    2. Press the 6 button and 2 button, then the 9 button on the
    remote commander (to initialize data).
    3. Set a disc (TCD-784).
    4. Press the 6 button and - button, then the 5 button on the
    remote commander. (Adjustment will take about 2 minutes.)
    5. Remove the disc when CD END is displayed.
    6. Set a disc (SATD-S2).
    7. Press the 6 button and - button, then the 5 button on the
    remote commander. (Adjustment will take about 1 minute 30
    seconds.)
    8. Remove the disc when SL END is displayed.
    9. Set a disc (SATD-S3).
    10. Press the 6 button and - button, then the 5 button on the
    remote commander. (Adjustment will take about 1 minute.)
    11. Remove the disc when DL END is displayed.
    Note: If an error is displayed during the adjustment so far, press again the
    6 button and - button on the remote commander to execute re-
    adjustment.
    12. Press the 6 button and 1 button on the remote commander.
    13. As the number and adjusted value are displayed, make sure
    that it is within the threshold.
    14. Press the 1 button on the remote commander to proceed to
    the next item. (To return to the previous item, press the 2
    button.)
    15. Repeat steps 13 and 14.
    16. After checking items up to No.43, press the 
    ! button to turn
    the power off.Thresholds for Overall Adjustment
    No. Description U limit L limit
    00 PI Level SL 0 4
    01 PI Level DL 3 7
    02 PI Offset CD 15D 2A3
    03 PI Offset SL 15D 2A3
    04 PI Offset DL 15D 2A3
    05 PI Offset Disc Check 100 2FF
    06 Traverse Offset CD
    07 Traverse Offset SL
    08 Traverse Offset DL
    09 Traverse Gain CD
    10 Traverse Gain SL
    11 Traverse Gain DL
    12 For PI Level Disc Check 0 2
    13 PI Reflectance SL 2D28 7333
    14 PI Reflectance DL 936 4083
    15 Surface Reflect to CD Layer Distance 82
    16 Surface Reflect to DSD Layer Distance 41 82
    17 Low Push-pull for Disc Check 4FDF 9999
    18 High T Bal for Disc Check 0000 47AE
    19 FE Offset CD
    20 FE Offset SL
    21 FE Offset DL
    22 Focus Bias CD E0 20
    23 Focus Bias SL E0 20
    24 Focus Bias DL0 E0 20
    25 AGC Focus Gain CD 1500 3000
    26 AGC Focus Gain DL 0851 1A00
    27 AGC Focus Gain SL 0C28 2500
    28 AGC Tracking Gain CD 1A00 3C00
    29 AGC Tracking Gain SL 1100 2500
    30 AGC Tracking Gain DL 1400 2700
    31 RF Loop Filter Offset CD F6 0A
    32 RF Loop Filter Offset DSD F6 0A
    33 Tilt Disordered Point CD +side
    34 Tilt Disordered Point CD -side
    35 Tilt Disordered Point SL +side
    36 Tilt Disordered Point SL -side
    37 Tilt Disordered Point DL +side
    38 Tilt Disordered Point DL -side/
    39 Tilt Offset CD F0 10
    40 Tilt Offset SL F0 10
    41 Tilt Offset DL F0 10
    42 Focus Balance SL
    43 Focus Balance DL
    Note:1. No threshold specified for      items.
    2. All thresholds are displayed in Hex. 
    						
    							16
    Adjustment Location:
    Ð MAIN Board (Component Side) Ð
    TP511
    (FOUT)TP515
    (PI) TP524
    (FE)TP501
    (VC)
    TP516
    (TE)TP521
    (GND)TP503
    (RF)
    TP703
    (MNT5)
    TP702
    (MNT4) 
    						
    							17 17
    SECTION  7
    DIAGRAMS
    7-1. NOTES FOR PRINTED WIRING BOARD AND SCHEMATIC DIAGRAM
    Note:
    The components identi-
    fied by mark 0 or dotted
    line with mark 0 are criti-
    cal for safety.
    Replace only with part
    number specified.Note:
    Les composants identifiŽs par
    une marque 0 sont critiques
    pour la sŽcuritŽ.
    Ne les remplacer que par une
    
    spŽcifiŽ. Note on Schematic Diagram:
    ¥ All capacitors are in µF unless otherwise noted.  pF: µµF
    50 WV or less are not indicated except for electrolytics
    and tantalums.
    ¥ All resistors are in W and 
    1/4
     W or less unless otherwise
    specified.
    ¥ % : indicates tolerance.
    ¥
    f: internal component.
    ¥5: fusible resistor.
    ¥C: panel designation.
    ¥U: B+ Line.
    ¥V: BÐ Line.
    ¥ Voltages and waveforms are dc with respect to ground in
    adjustment mode.
    no mark :STOP
    ( ) :SACD
    áá ññ:CD
    ¥ Voltages are taken with a VOM (Input impedance 10 MW).
    Voltage variations may be noted due to normal produc-
    tion tolerances.
    ¥ Waveforms are taken with a oscilloscope.
    Voltage variations may be noted due to normal produc-
    tion tolerances.
    ¥ Circled numbers refer to waveforms.
    ¥ Signal path.
    J: SACD
    c: CD
    I: DIGITAL OUT Note on Printed Wiring Board:
    ¥X: parts extracted from the component side.
    ¥Y: parts extracted from the conductor side.
    ¥
    a: Through hole.
    ¥b: Pattern from the side which enables seeing.
    (The other layers patterns are not indicated.)
    Caution:
    Pattern face side: Parts on the pattern face side seen from
    (Conductor Side) the pattern face are indicated.
    Parts face side: Parts  on the parts face side seen from
    (Component Side) the parts face are indicated.
    ¥ Indication of transistor
    C
    BThese are omitted.
    E Q
    ¥ Circuit Boards Location
    SW-L boardMAIN boardSTB boardPOWER boardAC boardCOAX board
    OPT board
    SW board
    BAL board (SCD-1
    )
    PIN board
    LOAD-SW board
    LOAD-MOT board 
    AUDIO board
    LOAD-CN board SW-R board DISPLAY board
    SLD-MOT board
    RF boardSLD-FG boar
    d 
    						
    							18 18
    SCD-1/777ES
    7-2. PRINTED  WIRING  BOARDS  Ð RF/SLD-FG/SLD-MOT Boards Ð ¥ See page 17 for Circuit Boards Location.
    IC001 E-2
    IC002 C-4
    IC003 A-3
    IC004 A-2
    IC005 C-3
    IC006 C-3
    IC007 C-2Ref. No. Location Ref. No. Location
    ¥ Semiconductor Location
    ÐRF BoardÐ
    Ref. No. Location
    IC010 A-2
    IC011 C-2
    IC012 A-1
    Q001 F-3
    Q002 B-5
    Q003 B-4Q004 B-4
    Q006 A-3
    Q007 D-5
    Q008 B-5
    Q009 B-5
    (Page 22)
    (Page 22) 
    						
    							19 19
    SCD-1/777ES
    7-3. SCHEMATIC  DIAGRAM  Ð RF/SLD-FG/SLD-MOT Boards Ð ¥ See page 40 for Waveforms.
    The components identified by mark 0 or dotted
    line with mark 0 are critical for safety.
    Replace only with part number specified.Les composants identifiŽs par une marque 0 sont
    critiques pour la sŽcuritŽ. Ne les remplacer que
    
    (Page
    29)
    (Page
    28) 
    						
    							20 20
    SCD-1/777ES
    7-4. PRINTED  WIRING  BOARDS  Ð LOAD-CN/LOAD-MOT/LOAD-SW/STB Boards Ð ¥ See page 17 for Circuit Boards Location.
    (Page 22) 
    						
    All Sony manuals Comments (0)

    Related Manuals for Sony Scd-1 Service Manual