Page 61
4. WIRING 4-12 4.3.4 Sensor Connection Diagram (ABS-E Request Signal-unavailable Absolute Encoder) Notes: 1. For the parts marked , use a twisted pair shielded cable. 2. Refer to 4.6.2 CN1 & CN2 Shielding Procedure. 3. The sensor power connection differs depending on the cable length. Refer to the following table. Sensor cable length 5 m or less 10 m or less 15 m or less 25 m or less +5 V wiring...
Page 62
4. WIRING 4-13 4.3.5 Sensor Connection Diagram (ABS-RII Request Signal-available Absolute Sensor) Notes: 1. For the parts marked , use a twisted pair shielded cable. 2. Refer to 4.6.2 CN1 & CN2 Shielding Procedure. 3. When the sensor cable length is 5m or less, 11, 12, 17 and 18 pins need not be connected. When the length is between 5 m and 30 m, connect all pins. Fig. 4-5 Sensor Connection...
Page 63
4. WIRING 4-14 4.3.6 Sensor Connection Diagram (Wiring-saved Absolute Sensor) Absolute sensor (E03B151302): Lead wire type Notes: 1. For the parts marked , use a twisted pair shielded cable. 2. Refer to 4.6.2 CN1 & CN2 Shielding Procedure. 3. The sensor power connection differs depending on the cable length. Refer to the following table. Sensor cable length 10 m or less 25 m or less 40 m or less +5 V wiring 19-pin connection (12 and 17 pins need not be...
Page 64
4. WIRING 4-15 4.4 Connector Terminal Arrangement Input/ Output Signal Diagram 4.4.1 CN1: Interface Connector CN1 is an interface connector to a host computer or the like. The connector of the amplifier is 10250-52A2JL (made by Sumitomo 3M). 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 BAT- BAT+ A A B B C C PS PS SGSG SGSGSG MON2 MON1COP COPG PIL NIL VCMDG TCMD TCMDG/ VCMD ~24V DC5V ~24V COM...
Page 65
4. WIRING 4-16 4.4.2 CN2 Sensor Connector The amplifier-side connector is 10220-52A2JL (made by Sumitomo 3M). ● Incremental encoder (INC-E) terminal arrangement diagram Fig. 4-8 CN2 Connector (INC-E Incremental Encoder) Terminal Arrangement Diagram ● Request signal-unavailable absolute encoder (ABS-E) terminal arrangement diagram Fig. 4-9 CN2 Connector (ABS-E Request Signal-unavailable Absolute Encoder)...
Page 66
4. WIRING 4-17 ● Request signal-available absolute sensor (ABS-RII) terminal arrangement diagram Fig. 4-10 CN2 Connector (ABS-RII Request Signal-available Absolute Sensor) Terminal Arrangement Diagram ● Wiring-saved absolute sensor (ABS-E.S1) terminal arrangement diagram Fig. 4-11 CN2 Connector (ABS-E.S1 Wiring-saved Absolute Sensor) Terminal Arrangement Diagram 2 4 REQ− 6 SG SG 8 SG 10 1 3 REQ+ 5 −5 V...
Page 67
4. WIRING 4-18 4.5 Wiring Procedure The Servo Amplifier is control unit to process signals of several mV or less. Therefore, perform wiring observing the following items. 1 Input/output or sensor signal line For the input/output or sensor signal line, use recommended cables or their equivalent (twisted wires or multi-conductor twisted lump shielded wires). Wire them by taking the following...
Page 68
4. WIRING 4-19 1 Noise processing The main circuit of the Servo Amplifier uses IGBTs under PWM control. If the wiring processing is not earthed properly, switching noise may occur by di/dt and dv/dt generated when IGBT is switched. Because the Servo Amplifier incorporates electronic circuits such as the CPU, it is necessary to perform wiring and processing so as to prevent external noise from invading to the utmost. To prevent trouble due to this noise in advance, perform wiring and...
Page 69
4. WIRING 4-20 6 Leakage current Even after the motor frame is grounded as specified, leakage current flows in the input power line. When selecting a leak detection-type breaker, make sure that no oversensitive operation is caused by high-frequency leakage current by referring to “Servo Amplifier/Servomotor Leakage Current” in the specifications. 7 Power supply surge When a surge voltage occurs in the power supply, connect a surge absorber between...
Page 70
4. WIRING 4-21 4.6.1 Recommended Surge Protector When purchasing the following, directly make a reference to the maker for it. Item Specification Model No. R.A.V-781BXZ-2A (Okaya Electric Industries Co., Ltd.) External dimensions Maximum allowable circuit voltage 300 Vrms Clamp voltage 783 V±10% Surge-resistant current 2500 A (waveform) 8 × 20 µs Surge-resistant voltage 20 kV (waveform) 1.2 × 50 µs Connection diagram Weight Approx. 100 g Fig. 4-12...