Page 1
F569696 Operating Instructions Split System Air Conditioner Model No. This air conditioner uses the refrigerant R410A. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Indoor Unit 26 36Nominal Capacity F2 Low Silhouette DuctedS-26PF2U6 26 36S-36PF2U6Indoor Unit Type Type Outdoor Unit Nominal Capacity U SingleOutdoor Unit Type Type U-36PE1U6 Cooling/Heating U-26PE1U6Remarks z Connectable outdoor unit lineup This booklet is the operating...
Page 2
2 CONTENTS Page PRODUCT INFORMATION ........................................................................................................... 2 ALERT SYMBOLS......................................................................................................................... 2 INSTALLATION LOCATION ...........................................................................................................3 ELECTRICAL REQUIREMENTS...
Page 3
3 INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. ELECTRICAL REQUIREMENTS SAFETY INSTRUCTIONS Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or...
Page 4
4 For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency. Do not sit or step on the unit. You may fall down accidentally. Do not turn the air conditioner on and off from the power mains switch. Use the ON/ OFF operation button. Do not stick...
Page 5
5 OPERATION CONDITION Use this air conditioner under the following temperature range. Single Split System * DBT: Dry bulb temperature * WBT: Wet bulb temperatureTemperature range (°F/°C)Indoor Outdoor *DBT *WBT *DBT *WBT CoolingMax. 90/32 77/25 115/46 –/– Min. 64/17.8 57/14 14/-10 –/– HeatingMax. 86/30 –/– 75/24 64/17.8 Min. 61/16 –/– -4/-20 -4/-20 F569696_SingleSplit_EN.fm Page 5 Tuesday, August 26, 2014 5:50 PM
Page 6
6 NAMES OF PARTS Timer Remote Controller (Optional parts) High-spec Wired Remote Controller (Optional parts) ADJUSTING AIRFLOW DIRECTION INDOOR UNIT LOW SILHOUETTE DUCTED F2 type (standard static pressure) Refer to the Operating Instructions attached to the optional Timer Remote Controller. Refer to the Operating Instructions attached to the optional High-spec Wired Remote Controller. „Low silhouette ducted type (F2) This air conditioner is not equipped with air outlet parts. These must be obtained...
Page 7
7 SPECIAL REMARKS How it works Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. The fan speed is set to ‘‘LO.’’ automatically, and cannot be adjusted. ‘‘DRY’’ operation is not possible if the outdoor temperature is 59°F or less. Heating performance Because this appliance heats a room by utilizing the...
Page 8
8 CARE AND CLEANING 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard. Air Intake and outlet side (Indoor Unit)Clean the air intake and outlet side of the indoor unit with a vacuum cleaner brush, or wipe them with a clean soft cloth. If these parts are stained, use a clean cloth moistened with a mild liquid detergent....
Page 9
9 TROUBLESHOOTING If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. INDOOR UNIT OUTDOOR UNITSymptom Cause Noise Sound like streaming water during operation or after operation Sound of refrigerant liquid flowing inside unit Sound of drainage water through drain pipe Cracking noise during operation or when operation stops.Cracking sound due to temperature changes of...
Page 10
10 CHECK BEFORE REQUIRING SERVICES If your air conditioner still does not work properly although you checked the points as described above, first stop the operation and turn off the power switch. Then contact your dealer and report the serial number and symptom. Never repair your air conditioner by yourself since it is very dangerous for you to do so. You also report if the inspection mark and the letters E, F, H, L, P in combination with the numbers appear on the LCD of the remote controller. TIPS...