Home > Panasonic > Camera Accessories > Panasonic Remote Operation Panel Ak Hrp931p Operating Instructions

Panasonic Remote Operation Panel Ak Hrp931p Operating Instructions

Here you can view all the pages of manual Panasonic Remote Operation Panel Ak Hrp931p Operating Instructions . The Panasonic manuals for Camera Accessories are available online for free. You can easily download all the documents as PDF.

Page 1

AK-HRP931P
Before attempting to connect, operate or adjust this product, please read these
instructions completely.
Remote Operation Panel 

Page 2

2
Safety precautions
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR  BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to
alert the user to the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to
persons.
The...

Page 3

3
Overview
≥This remote operation panel (ROP) is used to control a multi-format camera (AK-HC931P) and a camera control unit (CCU).  An
optical fiber cable is used to connect the multi-format camera and CCU, and a dedicated multi-cable (optional accessory) is used
to connect the ROP and CCU.
≥When the designated multi-cable is used to connect the ROP and CCU, the distance between these two components can be
extended to a maximum of 50 meters.
Contents
Overview...

Page 4

4
Operating precautions
≥The panel’s power is supplied from the camera control unit (AK-HCU931P).
≥Handle the panel carefully.
Dropping the panel or subjecting it to strong impact may cause malfunctioning and failures.
≥Operate the panel within a temperature range of 32 °F to 104 °F (0 °C to 40 °C).
Operation in locations below 32 °F or above 104 °F may adversely affect the internal parts.
≥Turn off the power before connecting or disconnecting the cables.
≥Do not use the ROP outdoors.
≥Maintenance...

Page 5

5
Parts and their functions
Camera number indicator [CAMERA NO.]
This indicates the camera number information.  If the camera
number is not indicated, “–” appears instead. 6
Camera video output selector switch
[CLOSE/BAR/ TEST]
This is used to select the camera video signals which are to
be output from the CCU’s rear panel.  The camera video
signal, color bar display signal or test display signal is
selected by pressing the BAR switch and/or TEST switch.
Both BAR and TEST switch lamps off:
Camera video...

Page 6

6
Parts and their functions
2Auto black balance switch [AUTO BLACK]
This is used to automatically adjust the black balance.
Lighted:This indicates that the automatic black balance
adjustment has started.
Flashing:This indicates that the automatic black balance
adjustment ended without being completed.
Off:This indicates that the automatic black balance
adjustment was completed correctly.
3Auto setup switch [AUTO SET UP]
This is used to perform auto setup.  The setup status is
output to PM each time.
The...

Page 7

7
Parts and their functions
15600K switch [5600K MODE]
This is used to change the amplification rate of the GBR
signals by an electrical circuit to achieve a white balance
that corresponds to the color temperature of 5600K.
When it is pressed, the B video signal is attenuated by
approximately -6 dB, the R video signal is boosted by
approximately 3 dB, and the G video signal is not
attenuated.  Select this switch setting for shooting under a
5600K light source or shooting outdoors.
When the lamp of the...

Page 8

8
Parts and their functions
VPAR: Vertical parabola correction
This is used to correct the coloring of black screen images
in the vertical direction in the range of –100 to 100.  When
the numerical setting is incremented, the video level at the
top and bottom of the screen is increased.
2White shading control switch
[WHITE SHADING CONTROL]
This is used to correct the white shading.  When it is
pressed and its lamp is lighted and when one of the
SHADING R, B or B switches is pressed and selected, the...

Page 9

9
Parts and their functions
9Flare control switch [FLARE CONTROL]
This is selected to change the amount of flare correction.
When it is selected, its lamp lights.
RFLRGFLRBFLR
10490
RFLR, GFLR, BFLR
These adjust the R, G or B flare in the range of –100 to
+100, and at 0 the flare correction operation is turned off.
:Gamma curve control switch [GAMMA CONTROL]
This is selected to adjust the gamma correction.  When it
is selected, its lamp lights.
Since the M GAM adjustment value is independent of the
R and...

Page 10

10
VDTLHDTLCRSP
000
PEAK1PEAK2
12
LDPDARK
10%2
CORNERSRC+CLP–CLP
3G00
KNEECRMCRSPCRED
0000
SKIN DTLSKIN_LVL
ONLOW
ZEBPHASWIDTHCRSP
ON123152
–CLP: Detail edge undershoot clip
This is used to limit the length of the undershoot parts of
the detail edge components.
+KNE: Detail edge overshoot knee
This function applies the knee to the detail edge overshoot
parts.
–KNE: Detail edge undershoot knee
This function applies the knee to the detail edge
undershoot parts.
KDTL: Knee detail
This is used to boost...