Have a look at the manual Panasonic Network Disk Recorder Wj Nd300 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. Network Disk Recorder IP Quick Setup Tool Operating Instructions Model No. WJ-ND300
2 Contents Limitation of Liability ........................................................................................................3 Disclaimer of Warranty .................................................................................................... 3 Precaution ....................................................................................................................... 3 Preface ............................................................................................................................ 4 System Configuration .................................................................................................. 4 System Requirement for a PC .................................................................................... 5 Trademarks and Registered Trademarks ................................................................... 5 Abbreviations .............................................................................................................. 5 Start/exit the software ...................................................................................................... 6 Main window ....................................................................................................................7 Icons in the tree display area ........................................................................................... 8 Operation flow .................................................................................................................9 Detect recorders/cameras and confirm the current settings ............................................ 11 Arrange the camera number by moving/deleting the camera icon .................................. 13 Move a camera icon .................................................................................................... 13 Delete a camera icon .................................................................................................. 14 Edit the settings ............................................................................................................... 16 Register the recorder and cameras, and confirm the result (CAM IP Auto Addressing) .............................................................................................. 17 Register the recorder and cameras, and confirm the result (Manual Registration) ......... 19 Tips to configure the settings .......................................................................................... 21 Troubleshooting ...............................................................................................................22
3 Limitation of Liability Precaution THIS PUBLICATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR NON-INFRINGEMENT OF THE THIRD PARTY’S RIGHT. THIS PUBLICATION COULD INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS. CHANGES ARE ADDED TO THE INFORMATION HEREIN, AT ANY TIME, FOR THE IMPROVEMENTS OF THIS PUBLICATION AND/OR THE CORRESPONDING PRODUCT (S). Distributing, copying, disassembling, reverse compiling, reverse engineering, and also exporting in violation of export laws of the software provided with this product, is expressively prohibited. Disclaimer of Warranty IN NO EVENT SHALL MATSUSHITA ELECTRIC INDUSTRIAL CO., LTD. BE LIABLE TO ANY PARTY OR ANY PERSON, EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT, FOR THE CASES, INCLUDING BUT NOT LIMITED TO BELOW: (1) ANY DAMAGE AND LOSS, INCLUDING WITHOUT LIMITATION, DIRECT OR INDIRECT, SPECIAL, CONSE- QUENTIAL OR EXEMPLARY, ARISING OUT OF OR RELATING TO THE PRODUCT; (2) PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR NEGLIGENT OPERATION OF THE USER; (3) UNAUTHORIZED DISASSEMBLE, REPAIR OR MODIFICATION OF THE PRODUCT BY THE USER; (4) ANY PROBLEM, CONSEQUENTIAL INCONVENIENCE, OR LOSS OR DAMAGE, ARISING OUT OF THE SYS- TEM COMBINED BY THE DEVICES OF THIRD PARTY; (5) ANY CLAIM OR ACTION FOR DAMAGES, BROUGHT BY ANY PERSON OR ORGANIZATION BEING A PHO- TOGENIC SUBJECT, DUE TO VIOLATION OF PRIVACY WITH THE RESULT OF THAT SURVEILLANCE- CAMERA’S PICTURE, INCLUDING SAVED DATA, FOR SOME REASON, BECOMES PUBLIC OR IS USED FOR THE PURPOSE OTHER THAN SURVEILLANCE.
4 Preface By using this software, the following settings of the digital disk recorder WJ-ND300 can be configured on a PC via a network. • Network settings • Registration of cameras, and deletion/edit of the registered cameras IP addresses of the cameras connected to the WJ-ND300 can be automatically assigned with this software. When using multiple network disk recorders, it is necessary to configure the above settings independently. This software works only when the software version of the WJ-ND300 is 3.00 or later. When failed to configure the above settings with this software, configure them using the setup menu of the WJ- ND300. To configure the settings of the connected cameras, use the setup software of the cameras. Refer to the setup instructions (PDF) of the WJ-ND300 or the operating instructions of the camera for further infor- mation. System Configuration To configure the settings with this software, connect the PC in which this software is installed to the client PC port of the WJ-ND300 and the camera to the camera port of the WJ-ND300. When the camera is connected to the client PC port, it is impossible to detect and configure the camera. Important: • This software is inoperable in a different subnet over a router. • The WJ-ND300 can be detected and configured using this software. However, for enhancing security, this soft- ware will not detect the WJ-ND300 when 20 minutes have passed after the power is turned on once the default settings are changed. To detect the WJ-ND300 after the settings have been changed, click the [Available] button of IP Setup Tool on the NW Camera Setup page (under the Camera page of the WJ-ND300 setup menu). Refer to the setup instructions (PDF) of the WJ-ND300 for further information. • Depending on the model of camera, this software will not detect it when 20 minutes have passed after the power is turned on once the default settings are changed. Refer to the operating instructions of the camera in use for further information. PC in which this software is installed Client PC port CameraCamera ALARMALARM SUSPENDOPERATEERRORTIMERREC1-LINK/ACT-2HDD1HDD2HDD3HDD4ESCSET PULL Network Disk RecorderWJ-ND Recorder Network Network Camera portPUSH TO LOCK/EJECT PUSH TO LOCK/EJECT Detection and configuration are unavailable
5 System Requirement for a PC This software is operable when installed on a PC that meets the following system requirements. OS Microsoft ®Windows®2000 Professional SP4 Microsoft®Windows®XP Professional SP2 Microsoft®Windows®XP Home Edition SP2 CPU Intel®Pentium®4 1.4 GHz or faster Memory 512 MB or more Monitor 1024 x 768 pixels or more Network interface 100 Mbps Network interface card must be installed Adobe ®Reader Required to read these operating instructions.When the Adobe®Reader is not installed on the PC, download the latest Adobe®Reader from the Adobe web site and install it. Trademarks and Registered Trademarks • Microsoft®and Windows®are registered trademarks of Microsoft Corporation in U.S. and/or other countries. • Intel®and Pentium®are trademarks of Intel Corporation. • Adobe®, Adobe logos, Acrobat®are registered trademarks of Adobe Systems Incorporated in the U.S. and/or other countries. • Other names of companies and product contained in these operating instructions may be trademarks or regis- tered trademarks of their respective owners. Abbreviations The following abbreviations are used in these operating instructions. • Microsoft®Windows®2000 Professional Service Pack 4 is described as Windows 2000. • Microsoft®Windows®XP Professional SP2 and Microsoft®Windows®XP Home Edition SP2 are described as Windows XP.
6 Start/exit the software Start:Double-click the IP Quick Setup Tool icon (ND300IPsetup.exe) to start this software. The software will start and the main window will be displayed. Exit:Click the [Exit] button on the main window or the [x] button at the top right of the window to exit the software. Notes: • When using a PC on which Windows XP SP2 is installed, the security warning window may be displayed when the IP setup tool is started. When this occurred, click the [Unblock(U)] button. • When multiple network interface cards are installed on the PC, the network adapter selection window will be dis- played when the software starts. Select a network adapter to be used.
7 Main window Tree display area Icons of the detected recorders and cameras will be displayed and their IP addresses and MAC addresses will be displayed. (When failed to detect the camera, its MAC address will not be displayed.) Refer to the next page for fur- ther information about the icons. Network settings area The network settings of the recorder/camera selected in the tree display area will be displayed. [Delete] button:Click this button to delete the icon of the selected recorder/camera. [Set] button:Click this button to determine the edited settings. [Clear] button:Click this button to cancel the edited settings and return to the previous settings. The settings will return to the previous settings only when the [Set] button is not clicked yet. [CAM IP Auto Addressing] button*:Click this button to register the edited settings in the recorder. IP addresses will automatically be assigned to the cameras connected to the recorder. [Manual Registration] button*:Click this button to register the edited settings to the recorder/camera. * The [CAM IP Auto Addressing] button and the [Manual Registration] button will be displayed only when the WJ- ND300 is selected in the tree display area. [Search] button:Click this button to search the connected recorder and the cameras connected to the recorder. The search result will be displayed in the tree area. [Exit] button:Click this button to exit this software. Tree display areaNetwork settings area
8 Icons in the tree display area Type RecorderIcon (Name) Description Indicates the network disk recorder WJ-ND300. (Normal display) This icon will be displayed when number of the detected cameras that are connected to the recorder is 33 or more. CameraIndicates a camera whose network settings are edited with this software. To apply the edited settings to the recorder/camera, it is necessary to register this camera again. Indicates a camera whose network information is not registered in the recorder. It is necessary to configure the network settings and register them in the recorder. Indicates that the network information of this camera is conformed to the information registered in the recorder and the camera. (Camera in normal status) Indicates that this camera is not applicable with this software to configure the network settings even though the network information of this camera is registered in the recorder. (Including cameras of other manufacturers) Network setting configuration is unavailable with this software. Indicates the camera whose host name is registered in the recorder, instead of IP address. Network setting configuration is unavailable with this software. Moving and copying the icon of this camera is also unavailable. Indicates a camera not detected even though its network information is registered in the recorder. For enhancing security, some cameras may not respond (not be detect- ed) even though whose status is normal. Indicates that the network information of this camera is not conformed to the information registered in the recorder and the camera (IP address, etc.) even though the camera is normally detected. This icon will be dis- played when there is no available IP address for this camera or when failed to automatically assign an IP address to this camera. Indicates the 33rd detected camera or later. The settings for this camera will not be applied since the recorder can register up to 32 cameras. Indicates that the camera number of this camera has been changed since this camera is deleted or moved. It is necessary to register this camera in the recorder again. When this camera is registered in the recorder again, it is necessary to configure the settings since the settings such as the recording rate will return to the default settings. (Recorder) (Recorder) (Edited)(New) (Camera in normal status) (Not applicable) (Host name) (Not detected) (Incorrect settings) (33rd or later) (Settings changed)
Change the settings (for the recorder and camera) (page 16) Register the recorder and cameras, and confirm the result. (Manual Registration) (page 19)Register the recorder and cameras, and confirm the result. (CAM IP Auto Addressing) (page 17) Change the settings (only for the recorder) (page 16) Arrange the camera number by moving/ deleting the camera icon (pages 13 and 14) Detect recorders/cameras and confirm the current settings. (page 11) 9 Operation flow The following settings can be configured with this software. • Network settings of the recorder (Camera port, client PC port) • Camera network settings of the recorder (Camera registration for each channel) • Network settings of the cameras connected to the recorder (IP address, etc.) Configure the network settings of the recorder/camera as follows. Important: • Any recording currently being performed on the recorder will stop in the processes of CAM IP Auto Addressing and Manual Registration. • The model WV-NS202 accepts Manual Registration only. Notes: • When using multiple recorders, repeat the above procedures for each recorder. • Do not change the network settings of the cameras and register the cameras with the automatically assigned IP addresses when automatically assigning IP addresses to the cameras. (page 17) To register the cameras with the automatically assigned IP addresses (when installing newly)To register the cameras with the manually assigned IP addresses
10 The settings for the recorder/camera will be different as follows according to how the registration is made (CAM IP Auto Addressing or Manual Registration). *1 CAM IP Auto Addressing is available only when OFF is selected for the DHCP setting of the camera. *2 The compression method will automatically be applied (JPEG/M-JPEG). *3 Check if the same IP addresses are not in use already even vacant IP addresses are searched and assigned automatically. When the message saying that no IP address is available is displayed, check the settings and per- form Manual Registration.Setup item Recorder CameraCamera port Client PC port Default gateway HTTP port number NW camera setup (Manufacturer, MODEL/COM- PRESSION, ADDRESS, Port number) Live image transmission rateDHCP setting IP address Subnet mask DHCP setting IP address Subnet maskEdited value Edited value Edited value Edited value Edited value Edited value Edited value Edited value Cameras will be registered for each channel with edited values.* 2 Fixed at 1 ipsOFF only * 1 Edited value Edited value Edited value Edited value Edited value Edited value Edited value Cameras will be registered for each channel with edited values.* 2 Fixed at 1 ips Rate settings other than the live image transmission rateDefault setting Default setting DHCP setting Edited value Fixed at OFF IP address Edited valueAuto incremented value (+1) starting from the IP address of the camera port of the recorder * 3 Subnet mask Edited valueSame value as for the camera port of the recorder Gateway HTTP port numberEdited value Edited valueSame value as for the default of the recorder Fixed at 80 Manual Registration CAM IP Auto Addressing