Page 41
41 Indication of lamp monitor This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal internal temperature. These lamps flash or light up to indicate a problem. Turn the power off and follow the steps below. Temperature monitor (TEMP) indicator Lamp 1 monitor (LAMP 1) Lamp 2 monitor (LAMP 2) • To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps on pages 22, 23. • If the main power turns off after the...
Page 42
42 Cleaning and replacement of air filter If too much dust is deposited in the air filter, temperature inside the main unit will rise and the temperature monitor (TEMP) blinks, eventually turning off the power supply. Clean the air filter section once every 100 hours or so as a guideline depending on the location of projector operation. Procedure of cleaning Turn off the main power and remove the power plug from the receptacle. Turn off the power supply observing the procedure (How to turn “OFF” the...
Page 43
43 Replacing the lamp unit Precautions on lamp unit replacement Remove the power plug and confirm that the surroundings of the lamp unit have cooled off. Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, explosion might result. A used lamp unit may burst if it is handled violently. For disposition of used lamps, request an industrial waste disposal contractor. Do not reset the cumulative time, except when the lamp unit has been replaced with a...
Page 44
44 Replacing the lamp unit Lamp unit replacement steps • After 1 500 hours (4 000 hours when long life lamp units are used) of operating the same lamp, it is only possible to operate the unit for approximately 10 minutes. Steps to must be completed within 10 minutes.Attention Turn the power off by following the steps on page 23, remove the power plug and confirm that the surroundings of the lamp unit have cooled off. Check that the fan has stopped running. Have a Phillips screwdriver ready ahead of...
Page 45
45 Insert the power cord plug into the wall outlet and then press the MAIN POWER switch. Press the “POWER” button so that a picture is projected onto the screen. Press the “MENU” button to display the MAIN MENU screen, and then press the and buttons to move the cursor to select “OPTION2”. Press the “ENTER” button to display the “OPTION2” screen, and select “SYSTEM INFORMATION” with the and buttons. Press the “ENTER” button. The SYSTEM INFORMATION screen will be displayed. Press and hold the “ENTER”...
Page 46
46 Using Web Browser Control Access procedure Start the web browser on your PC, then enter the IP address which was set in the projector. Enter “user1” in the user name field, then enter the password in the password field. The default setting is “panasonic” (all lower case). If you have changed the password, enter the new password here. The host name set in the projector is displayed in the “Realm” field. Click [OK]. The Basic Control page is displayed. • Do not enter settings or perform controls with...
Page 47
47 Detail control page Click [Projector Control], then [Detail control] to display the Detail control page. Status information page Click [Projector Control], then [Status information] to display the Status information page. This displays the status of the unit in the following items. Menu screen item entry and executionAutomatic screen display position settingFactory settings Number input (This function is used when a service person.) Menu display/non-display Temporary stop of video Lens adjustment Test...
Page 48
48 Using Web Browser Control If requesting service, ask your nearest Authorized Service Centre. Error information page When is displayed on the status information screen, click it to display the error details. • Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.Note When [FAILED] has appeared for an item OK: Normal operation FAILED: Occurrence of trouble LAMP REMAIN TIMEThe lamp runtime has exceeded the prescribed cumulative time, and it is now...
Page 49
49 E-mail setup page With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be sent to one or more preset e-mail addresses (maximum two addresses). Click [Projector Control], then [E-mail set up] to display the E-mail setup page. Button to update settings Minimum sending interval field (applies only to temperature warnings)E-mail Enable/Disable toggling SMTP server field Set temperature selection Memo field (alphanumeric characters) Sender field...
Page 50
50 Using Web Browser Control DNS server setup page Click [Network Setting], then [DNS Server set up] to display the DNS server setup page. Network config page Click [Network Setting], then [Network config] to display the Network config page. Primary DNS server address Available input characters: Numbers (0 - 9), period (.) (ex. 192.168.0.253) Button to update settings Secondary DNS server address Available input characters: Numbers (0 - 9), period (.) (ex. 192.168.0.254) Toggling between...