58 13.12.1 Human Activity Sensor Check Mode š To enable Human Activity sensor abnormality check mode, during ECONAVI operation ON: š During ECONAVI is ON, when CHECK signal received, if either sensors has abnormality, the 4 times abnormality counter is ignored, ECONAVI Indicator will blink immediately and error code is memorized. š The unit could operate without ECONAVI or AUTO COMFORT. š The ECONAVI indicator blinking could be cancelled by pressing ECONAVI button again. š If the human activity sensor has no abnormality, the CHECK process will end and continue with normal operation. SEPress continously for 5s Remote control normal mode TE TE SE TE TE SE SE Tr a n s m i t E C O d e m o c o d e and after 30 seconds return to normal mode. Transmit sunlight sensor check code and after 30 seconds return to normal mode. Transmit check code and after 30 seconds return to normal mode.
59 14. Operation Control (For Multi Split Connection) During multi split connection, indoor unit’s operation controls are same with single split connection unless specified in this chapter. 14.1 Cooling operation 14.1.1 Thermostat control š Capability supply to indoor unit is OFF (Expansion valve closed) when Intake Air Temperature — Internal setting temperature < 28.4°F. š Capability resume supply to indoor unit after waiting for 3 minutes, if the Intake Air temperature — Internal setting temperature > Capability supply OFF point. 14.2 Soft Dry Operation 14.2.1 Thermostat control š Capability supply to indoor unit is OFF (Expansion valve closed) when Intake Air Temperature « Internal setting temperature < 26.6°F. š Capability resume to indoor unit after waiting for 3 minutes, if the Intake Air temperature « Internal setting temperature > Capability supply OFF point. 14.3 Heating Operation 14.3.1 Thermostat control š Capability supply to indoor unit is OFF (Expansion valve closed) when Intake Air Temperature « Internal setting temperature > 33.8°F. š During this condition, the indoor fan is stopped if compressor is ON. š Capability resume supply to indoor unit after waiting for 3 minutes, if the Intake Air Temperature « Internal setting temperature < Capability supply OFF point. 14.3.2 Temperature Sampling Control š Temperature sampling is controlled by outdoor unit where room temperature for all power supply ON indoor unit could be obtained. š When capability supply to the indoor unit is OFF and the compressor is ON during heating operation, the indoor fan motor is stopped. During this condition, 15 seconds after sampling signal from outdoor unit is received, the indoor fan start operation at low fan speed. š However, within first 4 minutes of capability stopped supply to the indoor unit, even sampling signal is received, the sampling control is cancelled.
60 14.4 Automatic Operation (For Multi Split Connection Only) š This mode can be set using remote control and the operation is decided by remote control setting temperature, remote control operation mode, indoor intake and outdoor air temperature. š During operation mode judgment, indoor fan motor (with speed of -Lo) and outdoor fan motor are running for 30 seconds to detect the indoor intake and outdoor air temperature. The operation mode is decided based on below chart. š Every 180 minutes, the indoor and outdoor temperature is judge. Based on remote control setting temperature, the value of T1 will increase up to 50°F, T2 will decrease by 37.4°F and T3 will decrease up to 46.4°F. 14.5 Indoor Fan Motor Operation 14.5.1 Residual Heat Removal Control š To prevent high pressure at indoor unit, when heating mode thermostat-off condition or power supply OFF, indoor fan continue to operate at controlled fan speed for maximum 30 seconds then stop. 14.6 Powerful Mode Operation š When the power mode is selected, the internal setting temperature will shift lower up to 39.2“F for Cooling/Soft Dry or higher up to 42.8°F for heating than remote control setting temperature, the powerful operation continue until user cancel the Powerful operation by pressing powerful button again. 14.7 Auto restart control š When the power supply is cut off during the operation of air conditioner, the compressor will re-operate between three to four minutes (10 patterns to be selected randomly) after power resume. š During multi split connection, Indoor unit will resume previous mode, include unit standby mode. 14.8 Indication Panel LED POWER TIMER QUIET POWERFUL AUTO COMFORT ECONAVI Color Green Orange Orange Orange Green Green Light ON Operation ON Timer Setting ON Quiet Mode ON Powerful Mode ON Auto Comfort ON Econavi Mode ON Light OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful Mode OFF Auto Comfort OFF Econavi Mode OFF Note: š If POWER LED is blinking (0.5 second ON, 0.5 second OFF), the possible operation of the unit are during Indoor Residual Heat Removal, Hot Start, during Deice operation, operation mode judgment, or ON timer sampling. š If POWER LED is blinking (2.5 seconds ON, 0.5 second OFF), the unit is in standby mode. š If TIMER LED is blinking, there is an abnormality operation occurs. Indoor intake air temperature (“F) Heating Mode Soft Dry Mode Cooling Mode Remote Control setting temperature T1 T2 T3 96.8 60.8 66.2 55.4 69.8 73.4 77 Outdoor air temperature (“F)