Remote system access / 91 P0603534 02Modular ICS 6.1 Installer Guide The DISA DN and the Auto DN allow auto-answer private network and DID calls, in the same way that calls on auto-answer loop start and auto-answer E&M trunks can be answered, with or without DISA. These DNs are described in System prgming under Access codes. Remote access on Direct Inward Dial (DID) trunks Remote system access on DID trunks is similar to that of E&M trunks connected to a private network. The main differences are: •...
Page 93
P0603534 02Modular ICS 6.1 Installer Guide Controlling system access Modular ICS programming provides several ways of protecting your Norstar system from unauthorized access or use. These features are used in combination to provide control both to users and to lines. Class of Service Class of Service (COS) refers to the capabilities that Norstar provides to users who access the system from the public or private network. A password defines which set of capabilities the user has access to. The COS...
Page 94
94 / Controlling system access Modular ICS 6.1 Installer GuideP0603534 02 Restriction filters Restriction filters can be used to restrict the numbers that may be dialed on any external line within your Norstar system. Up to 100 restriction filters can be created for the system. A restriction filter consists of up to 48 restrictions with associated overrides. To restrict dialing within the system, you can apply filters to: • outgoing external lines (as line restrictions) • telephones (as set...
Page 95
Controlling system access / 95 P0603534 02Modular ICS 6.1 Installer Guide Line restrictions In the previous diagram, a caller using line 1 could only dial long-distance numbers to area codes 212 and 718. A caller using line 3 could not dial any long-distance numbers. A caller using line 5 could dial long-distance numbers to area codes 212, 718, and 415. Tips - Set restrictions have no effect on numbers dialed on an E&M trunk. To restrict dialing outside the system, once a caller gains remote...
Page 96
96 / Controlling system access Modular ICS 6.1 Installer GuideP0603534 02 Remote caller restrictions In this case, dialed digits must pass both the remote restriction and the line restriction. A remote caller can override these filters by dialing the DISA DN and entering a COS password. For restriction filter programming instructions, see Restrictions on page 339 and the Modular ICS 6.1 System Coordinator Guide. Direct inward system access (DISA) To control access from the public or private...
Page 97
Controlling system access / 97 P0603534 02Modular ICS 6.1 Installer Guide In addition to public network connections, Norstar Modular ICS can be integrated into an existing private network, or to other Norstar or Meridian 1 systems to form a corporate telecommunications network. Tips - You must have one E&M/DISA Trunk Cartridge to provide DTMF receivers for every two auto-answer loop start trunks on Loop Start or CI Trunk Cartridges. DID and PRI trunks cannot be configured to answer with DISA. If...
Page 99
P0603534 02Modular ICS 6.1 Installer Guide Networking with Norstar There are a number of ways you can network Norstar systems together, or network Norstar systems with other Nortel systems into private networks. What types of lines you use to perform the networking will determine the type of services that can be shared between systems. Keep in mind that each node (Norstar system) is considered an external system by every other node within the network, even though, to the users, it appears to be...
Page 100
100 / Tie-line networking Modular ICS 6.1 Installer GuideP0603534 02 Tie-line networking Norstar uses enhanced trunking to join other Norstar or customer equipment in a private network. This allows authorized users access to tie lines, central office lines, and Norstar features from outside the Norstar system. Callers using the Norstar Modular ICS system can: • call directly to a specific Norstar telephone • select an outgoing tie line to access a private network • select an outgoing tie line to...