Page 51
3. Installing Extensions and Trunks 3-2CONNECTING BLOCKS Working With DDK Connectors The system uses DDK type connectors for extensions, trunks and optional equipment. Using the 25-pair DDK Installation Cables (P/N 93090) that came with your system makes it easy to connect the PCBs to standard 66M1-50 connecting blocks. In general, each cabinet needs: One 66M1-50 block and DDK Installation Cable for exten- sions and optional equipment. One 66M1-50 block and DDK Installation Cable for trunks....
Page 52
3. Installing Extensions and Trunks3-3CONNECTING BLOCKS Figure 3-1 PUNCHING DOWN DDK INSTALLATION CABLESFigure 3-2 SECURING Figure 3-3 SECURING THE CABLES ON THE 28i THE CABLES ON THE 124i 926 - 47 66M1-50 Connecting Block WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT 926-38
Page 53
3. Installing Extensions and Trunks 3-4CONNECTING BLOCKS BLOCK TERMCOLOR CODEFUNCTION 25-PAIR CABLE 926 - 39 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 41 42 43 44 45 46 47 48 49 50 31 32 33 34 35 36 37 38 39 40WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU BLU-BLK BLK-ORN ORN-BLK BLK-GRN GRN-BLK BLK-BRN BRN-BLK BLK-SLT SLT-BLK YEL-BLU...
Page 54
3. Installing Extensions and Trunks3-5 CONNECTING EXTENSIONS Digital Station (DSTU) PCB Connections (Figure 3-5) The Digital Station PCB has DDK connectors for eight stations. Figure 3-5 DIGITAL STATION CONNECTIONS 1. Following the conventional color code, insert the DDK con- nectors into the PCB. For example, the first DSTU in the system would have these connections: Extension Port DDK Conn Pair 301 1 WHT-BLU / BLU-WHT 302 2 WHT-ORN / ORN-WHT 303 3 WHT-GRN / GRN-WHT 304 4 WHT-BRN / BRN WHT 305 5...
Page 55
3. Installing Extensions and Trunks 3-6 CONNECTING EXTENSIONS Digital Station (DSTU) PCB Connections (Cont’d) 5. Back at the MDF, run one pair of cross-connect wire between the pins on the B block and cross-connect block to complete the connection. 6. Install bridging clips as required. 7. After completing step 6, you should be able to place and answer calls at the extension. 8. Record your entries on Figure 3-4. Figure 3-6 CONNECTING DIGITAL TELEPHONES 625 Modular Jack 25-Pair DDK Installation Cable...
Page 56
3. Installing Extensions and Trunks3-7 CONNECTING EXTENSIONS Analog Station (ASTU) Connections(Figure 3-7) The Analog Station PCB has DDK connectors for four sta- tions. The 28i system allows for a maximum of 2 ASTU’s to be installed. On a 124i system, the maximum allowed is either 15 ASTU PCB’s with a DSTU PCB installed in slot 1, 2, or 3 (providing 60 analog station ports and 8 digital station ports) OR16 ASTU PCB’s with no DSTU PCB installed in the sys- tem (providing 64 analog station ports). Note:...
Page 57
3. Installing Extensions and Trunks 3-8 CONNECTING EXTENSIONS Analog Station (ASTU) Connections(Cont’d) 5. Back at the MDF, run one pair of cross-connect wire between the pins on the B block and cross-connect block to complete the connection. 6. Install bridging clips as required. 7. After completing step 6, you should be able to place and answer calls at the extension. 8. Record your entries on Figure 3-4. Figure 3-8 CONNECTING ANALOG TELEPHONES 625 Modular Jack 25-Pair DDK Installation Cable BLK YEL...
Page 58
3. Installing Extensions and Trunks3-9CONNECTING TRUNKS Analog Trunk (ATRU) PCB Connections(Figure 3-9) The Analog Trunk PCB has DDK connectors for four loop start CO trunks and a power failure telephone. Refer to Part 4: Installing Optional Equipment for instructions on connecting a power failure telephone. Figure 3-9 ANALOG TRUNK CONNECTIONS1. Following the conventional color code, insert the DDK con- nectors into the PCB. For example, the first ATRU in the system would have these connections: Trunk...
Page 59
3. Installing Extensions and Trunks 3-10CONNECTING TRUNKS Analog Trunk (ATRU) PCB Connections(Cont’d) 4. After completing step 3, you should be able to place and answer calls over the connected trunk. 5. Record your entries on Figure 3-4. Figure 3-10 CONNECTING ANALOG TRUNKS 25-Pair Cable to Central Office 25-Pair DDK Installation CableTelco RJ21X One-Pair Cross Connect A Block 926 - 46
Page 60
3. Installing Extensions and Trunks3-11CONNECTING TRUNKS Tie Line Trunk (2EMTU) PCB Connections(Figure 3-11) The Tie Line PCB has DDK connector for two 2-wire (Type 1) (4-conductor), two 2-wire Type 2 (6 conductor), four 4-wire (4 conductor) tie line trunks. 1. Following the conventional color code, insert the DDK con- nectors into the PCB. For example, the first 2EMTU PCB in the system would have these connections: Trunk DDK Connector Pair 1 WHT-BLU / BLU-WHT / WHT-ORN / ORN-WHT 2 WHT-GRN / GRN-WHT /...