Page 71

CHAPTER 5 CIRCUIT CARD INFORMATION
Mounting Location of Circuit Card
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 65
MOUNTING LOCATION OF CIRCUIT CARD
This section explains the conditions for mounting circuit cards for the Data Interface.
Figure 5-1 shows circuit card mounting slots allocated in the PIM.
Figure 5-1  Mounting Location of Circuit Card
*1PN-CP14 (MP) card on the MP12 slot on PIM0.
*2PN-24DTA-C/PN-30DTC-A (DTI) card on the AP00-AP11 slots on PIM0-PIM7....

Page 72

 NEAX2000 IVS2 Data Interface System ManualPage 66  ND-70924 (E), Issue 1.0
CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
LIST OF REQUIRED CIRCUIT CARDS
Table 5-1 shows the required circuit cards to be explained in this section.
*MB = Make Busy
Table 5-1  List of Required Circuit Cards
NAME
(FUNCTIONAL
NAME)
LAMP
X: PROVIDED
–: NOT
PROVIDEDSWITCH
X: PROVIDED
–: NOT
PROVIDEDEXTRACTION/
INSERTION WITH 
POWER ON
X: ALLOWED
: ALLOWED 
AFTER MB*
–: NOT ALLOWED
REFERENCE
PAGE
PN-CP14 (MP) X...

Page 73

CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 67
PN-CP14 (MP)
Locations of Lamps, Switches, and Connectors
CONN: To CONNR connector on PZ-M537 (EXPMEM)
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
CLK Green Remains lit while receiving clock signals to the PLO.
SW3
RUN
SW1
SW2
CLK
VR
DK JACK CONNSW4
JP0JP1
RS1
RS0 

Page 74

 NEAX2000 IVS2 Data Interface System ManualPage 68  ND-70924 (E), Issue 1.0
CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
Switch Settings
NOTE 1:Set the groove on the switch to the desired position.
NOTE 2:Only when executing “MP Program Download” in MATWorX, set the SW3 to 5-8.
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit 
card into/from its mounting slot.
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SW3 (Rotary...

Page 75

CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 69
SWITCH NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SW1 (Push SW) For initializing CPU
SW2
(Piano Key SW)1ON A-law (Australia)
OFF µ-law (North America)
2, 3Selection of PLO0 input
(Phase Locked Oscillator)
 For clock receiver office:
 For clock source office:
SW2-2
SW2-3
OFF OFF
4ONWhen using RS1 port for built-in 
MODEM
OFF When using RS1 port for...

Page 76

 NEAX2000 IVS2 Data Interface System ManualPage 70  ND-70924 (E), Issue 1.0
CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIO
NFUNCTION CHECK
SW4 (Dip SW)
1Not used
2Not used
3, 4Selection of PLO1 input
(Phase Locked Oscillator)
 For clock receiver office:
 For clock source office:
SW4-3
SW4-4
OFF OFF
VR (Rotary SW) Variable Resister for External Hold 
Tone Source
(0 - 20 Kohms : Clockwise)
DK (Connector)
02 Ground detection
01 Ground sending...

Page 77

CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 71
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and  , the setting of the switch varies with the system concerned.
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
JP0 (Jumper pin)
UPNot used
(Memory backup OFF)
For...

Page 78

 NEAX2000 IVS2 Data Interface System ManualPage 72  ND-70924 (E), Issue 1.0
CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
PN-24DTA-C (DTI)
Locations of Lamps, Switches and Connectors
SENSE
RUN
MB
 
 
CRC 
PCM 
FRM 
RMT 
AIS 
BL 
   
 
 
 
 
 
  SW1
SW0
JRR1
AISS MAS
JPR0
JPS 

Page 79

CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
NEAX2000 IVS2 Data Interface System Manual    
ND-70924 (E), Issue 1.0   Page 73
Lamp Indications
LAMP 
NAMECOLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) 
errors.
PCM Red Remains lit when detecting PCM signal loss.
FRM Red Remains lit when detecting Frame Alignment signal loss.
RMT Red Remains lit when receiving Frame Alignment signal...

Page 80

 NEAX2000 IVS2 Data Interface System ManualPage 74  ND-70924 (E), Issue 1.0
CHAPTER 5 CIRCUIT CARD INFORMATION
List of Required Circuit Cards
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
NOTE 10-3 Not used
4-F Set the switch to match the AP Number (04-31) to 
be set by CM05.
MB (Toggle SW)
NOTE 2UP For make-busy
For normal operation
(Continued)
F
4
AP No.SW1-4: ON04 05 06 07 08 09 10 11 12 13 14 15
SW1-4: OFF20 21 22 23 24 25 26 27 28 29 30 31
SW...