Page 71
CHAPTER 5 CIRCUIT CARD INFORMATION Mounting Location of Circuit Card NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 65 MOUNTING LOCATION OF CIRCUIT CARD This section explains the conditions for mounting circuit cards for the Data Interface. Figure 5-1 shows circuit card mounting slots allocated in the PIM. Figure 5-1 Mounting Location of Circuit Card *1PN-CP14 (MP) card on the MP12 slot on PIM0. *2PN-24DTA-C/PN-30DTC-A (DTI) card on the AP00-AP11 slots on PIM0-PIM7....
Page 72
NEAX2000 IVS2 Data Interface System ManualPage 66 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards LIST OF REQUIRED CIRCUIT CARDS Table 5-1 shows the required circuit cards to be explained in this section. *MB = Make Busy Table 5-1 List of Required Circuit Cards NAME (FUNCTIONAL NAME) LAMP X: PROVIDED –: NOT PROVIDEDSWITCH X: PROVIDED –: NOT PROVIDEDEXTRACTION/ INSERTION WITH POWER ON X: ALLOWED : ALLOWED AFTER MB* –: NOT ALLOWED REFERENCE PAGE PN-CP14 (MP) X...
Page 73
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 67 PN-CP14 (MP) Locations of Lamps, Switches, and Connectors CONN: To CONNR connector on PZ-M537 (EXPMEM) Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CLK Green Remains lit while receiving clock signals to the PLO. SW3 RUN SW1 SW2 CLK VR DK JACK CONNSW4 JP0JP1 RS1 RS0
Page 74
NEAX2000 IVS2 Data Interface System ManualPage 68 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards Switch Settings NOTE 1:Set the groove on the switch to the desired position. NOTE 2:Only when executing “MP Program Download” in MATWorX, set the SW3 to 5-8. CAUTION When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW3 (Rotary...
Page 75
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 69 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Push SW) For initializing CPU SW2 (Piano Key SW)1ON A-law (Australia) OFF µ-law (North America) 2, 3Selection of PLO0 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW2-2 SW2-3 OFF OFF 4ONWhen using RS1 port for built-in MODEM OFF When using RS1 port for...
Page 76
NEAX2000 IVS2 Data Interface System ManualPage 70 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards SWITCH NAMESWITCH NUMBERSETTING POSITIO NFUNCTION CHECK SW4 (Dip SW) 1Not used 2Not used 3, 4Selection of PLO1 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW4-3 SW4-4 OFF OFF VR (Rotary SW) Variable Resister for External Hold Tone Source (0 - 20 Kohms : Clockwise) DK (Connector) 02 Ground detection 01 Ground sending...
Page 77
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 71 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 (Jumper pin) UPNot used (Memory backup OFF) For...
Page 78
NEAX2000 IVS2 Data Interface System ManualPage 72 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards PN-24DTA-C (DTI) Locations of Lamps, Switches and Connectors SENSE RUN MB CRC PCM FRM RMT AIS BL SW1 SW0 JRR1 AISS MAS JPR0 JPS
Page 79
CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards NEAX2000 IVS2 Data Interface System Manual ND-70924 (E), Issue 1.0 Page 73 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. RMT Red Remains lit when receiving Frame Alignment signal...
Page 80
NEAX2000 IVS2 Data Interface System ManualPage 74 ND-70924 (E), Issue 1.0 CHAPTER 5 CIRCUIT CARD INFORMATION List of Required Circuit Cards Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3 Not used 4-F Set the switch to match the AP Number (04-31) to be set by CM05. MB (Toggle SW) NOTE 2UP For make-busy For normal operation (Continued) F 4 AP No.SW1-4: ON04 05 06 07 08 09 10 11 12 13 14 15 SW1-4: OFF20 21 22 23 24 25 26 27 28 29 30 31 SW...